  • Effect of loss of bond on flat-slab building collapses

    by Gerasimos Kotsovos, Emmanouil Vougioukas, Michael D. Kotsovos

    Between 1997 and 2010, there was a small, yet unexpected, number of flat-slab car park buildings that collapsed under service loading. In all the cases, the collapse was preceded by loss of bond (LoB) between the concrete and flexural reinforcement. All investigations of the causes of these collapses have since been inconclusive, particularly as regards the effect of LoB. Yet, LoB due to yielding of the flexural reinforcement in tension had already been proposed as the main cause of punching, and failure criteria derived on the basis of this proposal were found to produce predictions that correlated closely with experimentally established values of the punching failure load. The aim of the present work was to extend the range of application of these criteria to the case of LoB due to steel corrosion and test their validity against the available information on the car park building collapses.


  • Effect of loss of bond on the behaviour of RC beams under service load conditions

    by Emmanouil Vougioukas, Gerasimos Kotsovos, Apostolos Roulias, Michael D. Kotsovos

    Deviation of the flexural reinforcement spacing from code specifications appears to underly the cause of the loss of bond (LoB) between concrete and steel that preceded the unexpected collapse of the top-floor balcony of a building under service load conditions on 15 October 2021 in Athens. Although rare, LoB has also been identified as the cause of collapse of buildings under similar conditions in the UK and Canada. However, the codes of practice for reinforced concrete (RC) design neither make reference to the effect of LoB on structural behaviour, nor include LoB in the parameters that the formulae currently used for assessing load-carrying capacity are dependent on. In view of this, a description of the effect of LoB on the function of RC beams is provided in this paper and this description is used as the basis for the derivation of a formula linking LoB with load-carrying capacity. The validity of the proposed formula is verified using published experimental information on the subject. The proposed formula is used for the structural assessment of the collapsed balcony, taking into account the design details, physical state and loading conditions of structural members similar to the one that collapsed.