Rachel Hybart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Rachel Hybart has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Perry Ferris
University of Florida
3 shared publications Afzaal N. Mohammed
Center for Environmental Health Sciences, Department of Comparative Biomedical Sciences, College of Veterinary Medicine, Mississippi State University, MS, USA
1 shared publicationAubrey M. Lewis
Center for Environmental Health Sciences, Department of Comparative Biomedical Sciences, College of Veterinary Medicine, Mississippi State University, MS, USA
1 shared publicationDaniel Perry Ferris
J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States of America
1 shared publicationJenna A. Mosier
Center for Environmental Health Sciences, Department of Comparative Biomedical Sciences, College of Veterinary Medicine, Mississippi State University, MS, USA
1 shared publicationK. Siena Villancio-Wolter
J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States of America
1 shared publication
Latest Publications
- Open Access
- 13 November 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (11) , e0294241
Gait variability of outdoor vs treadmill walking with bilateral robotic ankle exoskeletons under proportional myoelectric control
Lower limb robotic exoskeletons are often studied in the context of steady-state treadmill walking in laboratory environments. However, the end goal of these devices is often adoption into our everyday lives. To move outside of the laboratory, there is a need to study exoskeletons in real world, complex environments. One way to study the human-machine interaction is to look at how the exoskeleton affects the user’s gait. In this study we assessed changes in gait spatiotemporal variability when using a robotic ankle exoskeleton under proportional myoelectric control both inside on a treadmill and outside overground. We hypothesized that walking with the exoskeletons would not lead to significant changes in variability inside on a treadmill or outside compared to not using the exoskeletons. In addition, we hypothesized that walking outside would lead to higher variability both with and without the exoskeletons compared to treadmill walking. In support of our hypothesis, we found significantly higher coefficients of variation of stride length, stance time, and swing time when walking outside both with and without the exoskeleton. We found a significantly higher variability when using the exoskeletons inside on the treadmill, but we did not see significantly higher variability when walking outside overground. The value of this study to the literature is that it emphasizes the importance of studying exoskeletons in the environment in which they are meant to be used. By looking at only indoor gait spatiotemporal measures, we may have assumed that the exoskeletons led to higher variability which may be unsafe for certain target populations. In the context of the literature, we show that variability due to robotic ankle exoskeletons under proportional myoelectric control does not elicit different changes in stride time variability than previously found in other daily living tasks (uneven terrain, load carriage, or cognitive tasks).
- 13 November 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (11) , e0294241
Open AccessGait variability of outdoor vs treadmill walking with bilateral robotic ankle exoskeletons under proportional myoelectric control
Lower limb robotic exoskeletons are often studied in the context of steady-state treadmill walking in laboratory environments. However, the end goal of these devices is often adoption into our everyday lives. To move outside of the laboratory, there is a need to study exoskeletons in real world, complex environments. One way to study the human-machine interaction is to look at how the exoskeleton affects the user’s gait. In this study we assessed changes in gait spatiotemporal variability when using a robotic ankle exoskeleton under proportional myoelectric control both inside on a treadmill and outside overground. We hypothesized that walking with the exoskeletons would not lead to significant changes in variability inside on a treadmill or outside compared to not using the exoskeletons. In addition, we hypothesized that walking outside would lead to higher variability both with and without the exoskeletons compared to treadmill walking. In support of our hypothesis, we found significantly higher coefficients of variation of stride length, stance time, and swing time when walking outside both with and without the exoskeleton. We found a significantly higher variability when using the exoskeletons inside on the treadmill, but we did not see significantly higher variability when walking outside overground. The value of this study to the literature is that it emphasizes the importance of studying exoskeletons in the environment in which they are meant to be used. By looking at only indoor gait spatiotemporal measures, we may have assumed that the exoskeletons led to higher variability which may be unsafe for certain target populations. In the context of the literature, we show that variability due to robotic ankle exoskeletons under proportional myoelectric control does not elicit different changes in stride time variability than previously found in other daily living tasks (uneven terrain, load carriage, or cognitive tasks).
- Open Access
Metabolic cost of walking with electromechanical ankle exoskeletons under proportional myoelectric control on a treadmill and outdoors
Lower limb robotic exoskeletons are often studied in the context of steady state treadmill walking in a laboratory environment. However, the end goal for exoskeletons is to be used in real world, complex environments. To reach the point that exoskeletons are openly adopted into our everyday lives, we need to understand how the human and robot interact outside of a laboratory. Metabolic cost is often viewed as a gold standard metric for measuring exoskeleton performance but is rarely used to evaluate performance at non steady state walking outside of a laboratory. In this study, we tested the effects of robotic ankle exoskeletons under proportional myoelectric control on the cost of transport of walking both inside on a treadmill and outside overground. We hypothesized that walking with the exoskeletons would lead to a lower cost of transport compared to walking without them both on a treadmill and outside. We saw no significant increases or decreases in cost of transport or exoskeleton mechanics when walking with the exoskeletons compared to walking without them both on a treadmill and outside. We saw a strong negative correlation between walking speed and cost of transport when walking with and without the exoskeletons. In the future, research should consider how performing more difficult tasks, such as incline and loaded walking, affects the cost of transport while walking with and without robotic ankle exoskeletons. The value of this study to the literature is that it emphasizes the importance of both hardware dynamics and controller design towards reducing metabolic cost of transport with robotic ankle exoskeletons. When comparing our results to other studies using the same hardware with different controllers or very similar controllers with different hardware, there are a wide range of outcomes as to metabolic benefit.
Open AccessMetabolic cost of walking with electromechanical ankle exoskeletons under proportional myoelectric control on a treadmill and outdoors
Lower limb robotic exoskeletons are often studied in the context of steady state treadmill walking in a laboratory environment. However, the end goal for exoskeletons is to be used in real world, complex environments. To reach the point that exoskeletons are openly adopted into our everyday lives, we need to understand how the human and robot interact outside of a laboratory. Metabolic cost is often viewed as a gold standard metric for measuring exoskeleton performance but is rarely used to evaluate performance at non steady state walking outside of a laboratory. In this study, we tested the effects of robotic ankle exoskeletons under proportional myoelectric control on the cost of transport of walking both inside on a treadmill and outside overground. We hypothesized that walking with the exoskeletons would lead to a lower cost of transport compared to walking without them both on a treadmill and outside. We saw no significant increases or decreases in cost of transport or exoskeleton mechanics when walking with the exoskeletons compared to walking without them both on a treadmill and outside. We saw a strong negative correlation between walking speed and cost of transport when walking with and without the exoskeletons. In the future, research should consider how performing more difficult tasks, such as incline and loaded walking, affects the cost of transport while walking with and without robotic ankle exoskeletons. The value of this study to the literature is that it emphasizes the importance of both hardware dynamics and controller design towards reducing metabolic cost of transport with robotic ankle exoskeletons. When comparing our results to other studies using the same hardware with different controllers or very similar controllers with different hardware, there are a wide range of outcomes as to metabolic benefit.
- Open Access
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 4, 119-128
Neuromechanical Adaptation to Walking With Electromechanical Ankle Exoskeletons Under Proportional Myoelectric Control
Objective: To determine if robotic ankle exoskeleton users decrease triceps surae muscle activity when using proportional myoelectric control, we studied healthy young participants walking with commercially available electromechanical ankle exoskeletons (Dephy Exoboot) with a novel controller. The vast majority of robotic lower limb exoskeletons do not have direct neural input from the user which makes adaptation of exoskeleton dynamics based on user intent difficult. Proportional myoelectric control has proven to allow considerable adaptation in muscle activation and gait kinematics in pneumatic, tethered ankle exoskeletons. In this study we quantified the changes in muscle activity and joint biomechanics of twelve participants walking for 30 minutes on a treadmill. Results: The exoskeletons provided 29% of the peak total ankle power and 18% of the peak total ankle moment by the end of the practice session. There was a decrease of 12% in soleus, 17% in lateral gastrocnemius and 5% in medial gastrocnemius electromyography (EMG) root mean square (root mean squared) after walking with the exoskeleton for 30 minutes compared to not wearing the exoskeleton, but this difference was not statistically significant. There were no differences in joint biomechanics of the ankle, hip, or knee between the end of training compared to walking without the exoskeletons. Conclusions: Contrary to expectations, triceps surae muscle activity showed only small non-significant decreases in 30 minutes of walking with portable, electromechanical ankle exoskeletons under proportional myoelectric control. The commercially available ankle exoskeletons were likely too weak to produce a statistically meaningful decline in triceps surae recruitment. Future research should include a wider variety of tasks, including measurements of metabolic energy expenditure, and provide a longer period of adaptation to evaluate the ankle exoskeletons.
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 4, 119-128
Open AccessNeuromechanical Adaptation to Walking With Electromechanical Ankle Exoskeletons Under Proportional Myoelectric Control
Objective: To determine if robotic ankle exoskeleton users decrease triceps surae muscle activity when using proportional myoelectric control, we studied healthy young participants walking with commercially available electromechanical ankle exoskeletons (Dephy Exoboot) with a novel controller. The vast majority of robotic lower limb exoskeletons do not have direct neural input from the user which makes adaptation of exoskeleton dynamics based on user intent difficult. Proportional myoelectric control has proven to allow considerable adaptation in muscle activation and gait kinematics in pneumatic, tethered ankle exoskeletons. In this study we quantified the changes in muscle activity and joint biomechanics of twelve participants walking for 30 minutes on a treadmill. Results: The exoskeletons provided 29% of the peak total ankle power and 18% of the peak total ankle moment by the end of the practice session. There was a decrease of 12% in soleus, 17% in lateral gastrocnemius and 5% in medial gastrocnemius electromyography (EMG) root mean square (root mean squared) after walking with the exoskeleton for 30 minutes compared to not wearing the exoskeleton, but this difference was not statistically significant. There were no differences in joint biomechanics of the ankle, hip, or knee between the end of training compared to walking without the exoskeletons. Conclusions: Contrary to expectations, triceps surae muscle activity showed only small non-significant decreases in 30 minutes of walking with portable, electromechanical ankle exoskeletons under proportional myoelectric control. The commercially available ankle exoskeletons were likely too weak to produce a statistically meaningful decline in triceps surae recruitment. Future research should include a wider variety of tasks, including measurements of metabolic energy expenditure, and provide a longer period of adaptation to evaluate the ankle exoskeletons.
- Open Access
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 657-668
Embodiment for Robotic Lower-Limb Exoskeletons: A Narrative Review
Research on embodiment of objects external to the human body has revealed important information about how the human nervous system interacts with robotic lower limb exoskeletons. Typical robotic exoskeleton control approaches view the controllers as an external agent intending to move in coordination with the human. However, principles of embodiment suggest that the exoskeleton controller should ideally coordinate with the human such that the nervous system can adequately model the input-output dynamics of the exoskeleton controller. Measuring embodiment of exoskeletons should be a necessary step in the exoskeleton development and prototyping process. Researchers need to establish high fidelity quantitative measures of embodiment, rather than relying on current qualitative survey measures. Mobile brain imaging techniques, such as high-density electroencephalography, is likely to provide a deeper understanding of embodiment during human-machine interactions and advance exoskeleton research and development. In this review we show why future exoskeleton research should include quantitative measures of embodiment as a metric of success.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 657-668
Open AccessEmbodiment for Robotic Lower-Limb Exoskeletons: A Narrative Review
Research on embodiment of objects external to the human body has revealed important information about how the human nervous system interacts with robotic lower limb exoskeletons. Typical robotic exoskeleton control approaches view the controllers as an external agent intending to move in coordination with the human. However, principles of embodiment suggest that the exoskeleton controller should ideally coordinate with the human such that the nervous system can adequately model the input-output dynamics of the exoskeleton controller. Measuring embodiment of exoskeletons should be a necessary step in the exoskeleton development and prototyping process. Researchers need to establish high fidelity quantitative measures of embodiment, rather than relying on current qualitative survey measures. Mobile brain imaging techniques, such as high-density electroencephalography, is likely to provide a deeper understanding of embodiment during human-machine interactions and advance exoskeleton research and development. In this review we show why future exoskeleton research should include quantitative measures of embodiment as a metric of success.
- Open Access
- 13 May 2022
- Published by Symbiosis Group in International Journal of Scientific Research in Environmental Science and Toxicology
- Vol. 5 (1) , 1-9
Inhibition of Serum Esterases in Juvenile Rats Repeatedly Exposed to Low Levels of Chlorpyrifos
In this paper, the feasibility of electrocoagulation technique for the adsorption of Styrene acrylate SA from aqueous solution has been studied.
- 13 May 2022
- Published by Symbiosis Group in International Journal of Scientific Research in Environmental Science and Toxicology
- Vol. 5 (1) , 1-9
Open AccessInhibition of Serum Esterases in Juvenile Rats Repeatedly Exposed to Low Levels of Chlorpyrifos
In this paper, the feasibility of electrocoagulation technique for the adsorption of Styrene acrylate SA from aqueous solution has been studied.