Shari Pepplinkhuizen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shari Pepplinkhuizen has a total of 169 co-authors. Here are the top co-authors by number of shared publications:
- Reinoud Elwin Knops
Department of Cardiology, Amsterdam University Medical Center , Amsterdam
8 shared publications - Lonneke Smeding
Department of Cardiology, University of Amsterdam, Amsterdam, the Netherlands (L.R.A.O.N., J.A.d.V., L.V.A.B., A.d.W., J.R.d.G., L.A.D., S.P., W.v.d.S., K.M.K., A.B.E.Q., T.F.B., A.A.M.W., L.S., R.E.K.).
7 shared publications - Willeke van der Stuijt
Amsterdam University Medical Centre, Department of Cardiology, Amsterdam, the Netherlands
7 shared publications - Arthur Arnold Maria Wilde
ERN GUARD‐Heart Amsterdam the Netherlands
6 shared publications - Anne-Floor B. E. Quast
Department of Cardiology, University of Amsterdam, Amsterdam, the Netherlands (L.R.A.O.N., J.A.d.V., L.V.A.B., A.d.W., J.R.d.G., L.A.D., S.P., W.v.d.S., K.M.K., A.B.E.Q., T.F.B., A.A.M.W., L.S., R.E.K.).
5 shared publications - Jolien A. de Veld
Amsterdam UMC location University of Amsterdam, Heart Center, Department of Cardiology, Amsterdam Cardiovascular Sciences Heart Failure & Arrhythmias, Amsterdam, The Netherlands
5 shared publications
Latest Publications
- Open Access
- 25 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (6) , 520-531
Subcutaneous Defibrillator Implantation With or Without Defibrillation Test: The Primary Results of the Randomized PRAETORIAN-DFT Trial
Background: To improve survival in patients at risk of sudden cardiac death, subcutaneous ICDs (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes based on chest X-rays. The PRAETORIAN-DFT trial evaluated whether omission of DF testing guided by the PRAETORIAN score is non-inferior for first-shock efficacy. Methods: In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary endpoint was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for non-inferiority with a 3% absolute risk margin. Secondary endpoints included mortality, potential DF testing-related complications, and S-ICD revisions. Results: The included 965 patients (No-DF testing, n=483;DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (–0.6%, 95% CI [ –2.6 to 1.4]; p<0.001). There were no significant differences in all-cause mortality (HR 0.9 [95% CI 0.6–1.4]) or arrhythmic death (HR 0.4 [95% CI 0.04–3.4]). Potential DF testing-related complications occurred in 1.7% in the DF testing group. Postoperative S-ICD revisions due to inadequate positioning were identical between groups (n=2 each). Conclusions: PRAETORIAN score–guided omission of DF testing- after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. (Funded by Boston Scientific; PRAETORIAN-DFT).
- 25 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (6) , 520-531
Open AccessSubcutaneous Defibrillator Implantation With or Without Defibrillation Test: The Primary Results of the Randomized PRAETORIAN-DFT Trial
Background: To improve survival in patients at risk of sudden cardiac death, subcutaneous ICDs (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes based on chest X-rays. The PRAETORIAN-DFT trial evaluated whether omission of DF testing guided by the PRAETORIAN score is non-inferior for first-shock efficacy. Methods: In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary endpoint was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for non-inferiority with a 3% absolute risk margin. Secondary endpoints included mortality, potential DF testing-related complications, and S-ICD revisions. Results: The included 965 patients (No-DF testing, n=483;DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (–0.6%, 95% CI [ –2.6 to 1.4]; p<0.001). There were no significant differences in all-cause mortality (HR 0.9 [95% CI 0.6–1.4]) or arrhythmic death (HR 0.4 [95% CI 0.04–3.4]). Potential DF testing-related complications occurred in 1.7% in the DF testing group. Postoperative S-ICD revisions due to inadequate positioning were identical between groups (n=2 each). Conclusions: PRAETORIAN score–guided omission of DF testing- after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. (Funded by Boston Scientific; PRAETORIAN-DFT).
- Top Cited PapersOpen Access
- 22 July 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (3) , 172-182
Device-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.1 months. Complications associated with transvenous leads are expected to occur after longer follow-up. The PRAETORIAN-XL trial aims to investigate whether the S-ICD is superior to the TV-ICD with respect to device-related complications at 8-year follow-up. METHODS: The PRAETORIAN trial randomized patients with a class I or IIa indication for ICD therapy without the need for pacing to either S-ICD or TV-ICD among 39 centers in the United States and Europe between March 2011 and January 2017. The follow-up was extended after 49.1 months by an additional 4 years for the PRAETORIAN-XL trial. The primary end point was the composite of all device-related complications. Complications could be related or unrelated to the lead and minor or major, with major complications being those requiring an invasive intervention. End points were analyzed according to the modified intention-to-treat principle using a Fine-Gray subdistribution hazards model to account for competing risks. An as-treated analysis was performed using a Cox proportional hazards model with device type as time-dependent variable. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). Twenty-one percent of the S-ICD group versus 18% of the TV-ICD group were women. The median age at implantation was 63 (interquartile range, 54–69) years for the S-ICD and 64 (interquartile range, 56–69) years for the TV-ICD. After a median follow-up of 87.5 months, all device-related complications (major and minor combined) were not significantly different in the modified intention-to-treat analysis (subdistribution hazard ratio, 0.73 [95% CI, 0.48–1.12]); P =0.15). However, TV-ICD patients more often had a major complication or lead-related complication ( P =0.03 and P P =0.047). CONCLUSIONS: The PRAETORIAN-XL trial demonstrated that there was no significant difference between the S-ICD and TV-ICD in all device-related complications during long-term follow-up. However, the TV-ICD carries a higher risk of major and lead-related complications compared with S-ICD therapy. The S-ICD should therefore be considered for all patients without a pacing indication who are evaluated for ICD therapy. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- 22 July 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (3) , 172-182
Top Cited PapersOpen AccessDevice-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.1 months. Complications associated with transvenous leads are expected to occur after longer follow-up. The PRAETORIAN-XL trial aims to investigate whether the S-ICD is superior to the TV-ICD with respect to device-related complications at 8-year follow-up. METHODS: The PRAETORIAN trial randomized patients with a class I or IIa indication for ICD therapy without the need for pacing to either S-ICD or TV-ICD among 39 centers in the United States and Europe between March 2011 and January 2017. The follow-up was extended after 49.1 months by an additional 4 years for the PRAETORIAN-XL trial. The primary end point was the composite of all device-related complications. Complications could be related or unrelated to the lead and minor or major, with major complications being those requiring an invasive intervention. End points were analyzed according to the modified intention-to-treat principle using a Fine-Gray subdistribution hazards model to account for competing risks. An as-treated analysis was performed using a Cox proportional hazards model with device type as time-dependent variable. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). Twenty-one percent of the S-ICD group versus 18% of the TV-ICD group were women. The median age at implantation was 63 (interquartile range, 54–69) years for the S-ICD and 64 (interquartile range, 56–69) years for the TV-ICD. After a median follow-up of 87.5 months, all device-related complications (major and minor combined) were not significantly different in the modified intention-to-treat analysis (subdistribution hazard ratio, 0.73 [95% CI, 0.48–1.12]); P =0.15). However, TV-ICD patients more often had a major complication or lead-related complication ( P =0.03 and P P =0.047). CONCLUSIONS: The PRAETORIAN-XL trial demonstrated that there was no significant difference between the S-ICD and TV-ICD in all device-related complications during long-term follow-up. However, the TV-ICD carries a higher risk of major and lead-related complications compared with S-ICD therapy. The S-ICD should therefore be considered for all patients without a pacing indication who are evaluated for ICD therapy. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- Open Access
- 16 January 2025
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (7) , 1-10
Antithrombotic therapy and the risk of pocket hematoma after subcutaneous implantable cardioverter-defibrillator implantation
Background: Little data exists regarding the optimal antithrombotic strategy during S-ICD implantation to prevent pocket hematomas. This study explores the association between perioperative antithrombotic management and the occurrence of pocket hematoma following S-ICD implantation. Methods: All patients who underwent de novo S-ICD implantation between February 2009 and January 2023 at Amsterdam UMC were included. Data was collected retrospectively from electronic patient records. Clinically significant pocket hematomas were defined as an accumulation of blood at the pocket site within 30 days after implantation. Results: A total of 347 patients were included of which 224 (64.6%) patients used antithrombotic therapy pre-implantation. The median age at implantation was 50 years (IQR 36–61 years), 33.4% of the patients were female, and the majority of implants were intermuscular (90.2%). A total of 18 patients (5.2%) developed a clinically significant pocket hematoma. There were significantly more pocket hematomas in patients with continued vitamin K antagonists (VKA) compared to patients with interrupted VKA (27.3% (6/22) vs. 4.3% (2/47), respectively, p = 0.01), and continuation of VKA was an independent predictor for pocket hematoma formation in the VKA group (p = 0.04). Moreover, continuation of dual antiplatelet therapy (DAPT) with ticagrelor was associated with significantly more pocket hematomas post-implantation compared to continuation of DAPT with clopidogrel (4/12 vs. 1/28, respectively, p = 0.02). Conclusion: Continuation of VKA during S-ICD implantation was associated with an increased risk of pocket hematoma formation compared to interruption of VKA. This supports the need for specific perioperative antithrombotic therapy guidelines for S-ICD implantations to reduce the risk of pocket hematomas. Graphical
- 16 January 2025
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (7) , 1-10
Open AccessAntithrombotic therapy and the risk of pocket hematoma after subcutaneous implantable cardioverter-defibrillator implantation
Background: Little data exists regarding the optimal antithrombotic strategy during S-ICD implantation to prevent pocket hematomas. This study explores the association between perioperative antithrombotic management and the occurrence of pocket hematoma following S-ICD implantation. Methods: All patients who underwent de novo S-ICD implantation between February 2009 and January 2023 at Amsterdam UMC were included. Data was collected retrospectively from electronic patient records. Clinically significant pocket hematomas were defined as an accumulation of blood at the pocket site within 30 days after implantation. Results: A total of 347 patients were included of which 224 (64.6%) patients used antithrombotic therapy pre-implantation. The median age at implantation was 50 years (IQR 36–61 years), 33.4% of the patients were female, and the majority of implants were intermuscular (90.2%). A total of 18 patients (5.2%) developed a clinically significant pocket hematoma. There were significantly more pocket hematomas in patients with continued vitamin K antagonists (VKA) compared to patients with interrupted VKA (27.3% (6/22) vs. 4.3% (2/47), respectively, p = 0.01), and continuation of VKA was an independent predictor for pocket hematoma formation in the VKA group (p = 0.04). Moreover, continuation of dual antiplatelet therapy (DAPT) with ticagrelor was associated with significantly more pocket hematomas post-implantation compared to continuation of DAPT with clopidogrel (4/12 vs. 1/28, respectively, p = 0.02). Conclusion: Continuation of VKA during S-ICD implantation was associated with an increased risk of pocket hematoma formation compared to interruption of VKA. This supports the need for specific perioperative antithrombotic therapy guidelines for S-ICD implantations to reduce the risk of pocket hematomas. Graphical
- Open Access
- 1 December 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (12) , e012836
Inappropriate Therapy and Shock Rates Between the Subcutaneous and Transvenous Implantable Cardiac Defibrillator: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: Inappropriate therapy (IAT) is an undesirable side effect of implantable cardiac defibrillator (ICD) therapy. Early studies with the subcutaneous ICD (S-ICD) showed relatively high inappropriate shock (IAS) rates. The PRAETORIAN (Prospective Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) trial demonstrated that the S-ICD is noninferior to the transvenous ICD (TV-ICD) with regard to the combined end point of IAS and complications. This secondary analyses evaluates all IAT in the PRAETORIAN trial. METHODS: This international, multicenter trial randomized 849 patients with an indication for ICD therapy between S-ICD (n=426) and TV-ICD therapy (n=423). ICD programming was mandated by protocol. All analysis were performed in the modified intention-to-treat population. RESULTS: In both groups 42 patients experienced IAT (48-month Kaplan-Meier estimated cumulative incidence, 9.9% and 10.1%, respectively; hazard ratio (HR), 0.99 [95% CI, 0.65–1.52]; P =0.97). There was no significant difference in patients experiencing IAS between both groups ( P =0.14). In the S-ICD group, 81 IAT episodes with 124 IAS and 1 inappropriate antitachycardia pacing occurred versus 89 IAT episodes with 130 IAS and 124 inappropriate antitachycardia pacing in the TV-ICD group. IAT episodes were most frequently caused by supraventricular tachycardias in the TV-ICD group (n=83/89) versus cardiac oversensing in the S-ICD group (n=40/81). In the TV-ICD group, a baseline heart rate >80 bpm (HR, 1.99 [95% CI, 1.05–3.76]; P =0.03), a history of atrial fibrillation (HR, 2.66 [95% CI, 1.41–5.02]; P =0.003), and smoking (HR, 2.46 [95% CI, 1.31–4.09]; P =0.005) were independent predictors for IAT. A QRS duration >120 ms was an independent predictor for IAT caused by cardiac oversensing in the S-ICD group (HR, 3.13 [95% CI, 1.34–7.31]; P =0.008). Post-IAS interventions significantly reduced IAS recurrence in both groups ( P =0.046). CONCLUSIONS: There was no significant difference in IAT and IAS rates between the S-ICD and TV-ICD in a conventional ICD population, but causes and predictors for IAT differed between the devices. After the first IAS, an intervention significantly reduced the recurrence rate of IAS. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- 1 December 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (12) , e012836
Open AccessInappropriate Therapy and Shock Rates Between the Subcutaneous and Transvenous Implantable Cardiac Defibrillator: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: Inappropriate therapy (IAT) is an undesirable side effect of implantable cardiac defibrillator (ICD) therapy. Early studies with the subcutaneous ICD (S-ICD) showed relatively high inappropriate shock (IAS) rates. The PRAETORIAN (Prospective Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) trial demonstrated that the S-ICD is noninferior to the transvenous ICD (TV-ICD) with regard to the combined end point of IAS and complications. This secondary analyses evaluates all IAT in the PRAETORIAN trial. METHODS: This international, multicenter trial randomized 849 patients with an indication for ICD therapy between S-ICD (n=426) and TV-ICD therapy (n=423). ICD programming was mandated by protocol. All analysis were performed in the modified intention-to-treat population. RESULTS: In both groups 42 patients experienced IAT (48-month Kaplan-Meier estimated cumulative incidence, 9.9% and 10.1%, respectively; hazard ratio (HR), 0.99 [95% CI, 0.65–1.52]; P =0.97). There was no significant difference in patients experiencing IAS between both groups ( P =0.14). In the S-ICD group, 81 IAT episodes with 124 IAS and 1 inappropriate antitachycardia pacing occurred versus 89 IAT episodes with 130 IAS and 124 inappropriate antitachycardia pacing in the TV-ICD group. IAT episodes were most frequently caused by supraventricular tachycardias in the TV-ICD group (n=83/89) versus cardiac oversensing in the S-ICD group (n=40/81). In the TV-ICD group, a baseline heart rate >80 bpm (HR, 1.99 [95% CI, 1.05–3.76]; P =0.03), a history of atrial fibrillation (HR, 2.66 [95% CI, 1.41–5.02]; P =0.003), and smoking (HR, 2.46 [95% CI, 1.31–4.09]; P =0.005) were independent predictors for IAT. A QRS duration >120 ms was an independent predictor for IAT caused by cardiac oversensing in the S-ICD group (HR, 3.13 [95% CI, 1.34–7.31]; P =0.008). Post-IAS interventions significantly reduced IAS recurrence in both groups ( P =0.046). CONCLUSIONS: There was no significant difference in IAT and IAS rates between the S-ICD and TV-ICD in a conventional ICD population, but causes and predictors for IAT differed between the devices. After the first IAS, an intervention significantly reduced the recurrence rate of IAS. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- Open Access
- 1 November 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 17 (11) , e010822
Quality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- 1 November 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 17 (11) , e010822
Open AccessQuality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
- Open Access
- 3 August 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (2) , 388-393
Effect of posture on position of subcutaneous implantable cardioverter-defibrillator
- 3 August 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (2) , 388-393
Open AccessEffect of posture on position of subcutaneous implantable cardioverter-defibrillator
- Open Access
- 8 February 2024
- Published by Elsevier in Heart Rhythm
- Vol. 21 (6) , 836-844
Predictive value of the PRAETORIAN score for defibrillation test success in patients with subcutaneous ICD: A subanalysis of the PRAETORIAN-DFT trial
- 8 February 2024
- Published by Elsevier in Heart Rhythm
- Vol. 21 (6) , 836-844
Open AccessPredictive value of the PRAETORIAN score for defibrillation test success in patients with subcutaneous ICD: A subanalysis of the PRAETORIAN-DFT trial
- 1 August 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (8) , 421-432
Initial Experience With Intercostal Insertion of an Extravascular ICD Lead Compatible With Existing Pulse Generators
BACKGROUND: This study assessed safety and feasibility of a novel extravascular implantable cardioverter defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Currently available or investigational, extravascular-ICDs include a subcutaneous or subxiphoid lead connected to customized extravascular-ICD PGs. METHODS: This novel extravascular-ICD (AtaCor Medical Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. In this nonrandomized, single-center, acute study, 36 de novo or replacement ICD (transvenous ICD) patients enrolled to receive a concomitant extravascular-ICD lead inserted through an intercostal space along the left parasternal margin. extravascular-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped up or down in 5 to 10 joule increments depending on the success and limitations of the generator used. RESULTS: Successful acute defibrillation using ≤35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3±8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0±8.4 J). Furthermore, 24 of 27 (89%) of patients tested with a left, mid-axillary intermuscular PG had successful VF conversion with defibrillation energies at least 10 J below the maximum delivered output of the device. All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. CONCLUSIONS: This first-in-human study documented the safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD PGs.
- 1 August 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (8) , 421-432
Initial Experience With Intercostal Insertion of an Extravascular ICD Lead Compatible With Existing Pulse Generators
BACKGROUND: This study assessed safety and feasibility of a novel extravascular implantable cardioverter defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Currently available or investigational, extravascular-ICDs include a subcutaneous or subxiphoid lead connected to customized extravascular-ICD PGs. METHODS: This novel extravascular-ICD (AtaCor Medical Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. In this nonrandomized, single-center, acute study, 36 de novo or replacement ICD (transvenous ICD) patients enrolled to receive a concomitant extravascular-ICD lead inserted through an intercostal space along the left parasternal margin. extravascular-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped up or down in 5 to 10 joule increments depending on the success and limitations of the generator used. RESULTS: Successful acute defibrillation using ≤35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3±8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0±8.4 J). Furthermore, 24 of 27 (89%) of patients tested with a left, mid-axillary intermuscular PG had successful VF conversion with defibrillation energies at least 10 J below the maximum delivered output of the device. All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. CONCLUSIONS: This first-in-human study documented the safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD PGs.
- Open Access
- 28 June 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (7)
Successful defibrillation testing in patients undergoing elective subcutaneous implantable cardioverter-defibrillator generator replacement
After implantation of a subcutaneous implantable cardioverter-defibrillator (S-ICD), a defibrillation test (DFT) is performed to ensure that the device can effectively detect and terminate the induced ventricular arrhythmia. Data on DFT efficacy at generator replacement are scarce with a limited number of patients and conflicting results. This study evaluates conversion efficacy during DFT at elective S-ICD generator replacement in a large cohort from our tertiary centre. Retrospective data of patients who underwent an S-ICD generator replacement for battery depletion with subsequent DFT between February 2015 and June 2022 were collected. Defibrillation test data were collected from both implant and replacement procedures. PRAETORIAN scores at implant were calculated. Defibrillation test was defined unsuccessful when two conversions at 65 J failed. A total of 121 patients were included. The defibrillation test was successful in 95% after the first and 98% after two consecutive tests. This was comparable with success rates at implant, despite a significant rise in shock impedance (73 ± 23 vs. 83 ± 24 Ω, P < 0.001). Both patients with an unsuccessful DFT at 65 J successfully converted with 80 J. This study shows a high DFT conversion rate at elective S-ICD generator replacement, which is comparable to conversion rates at implant, despite a rise in shock impedance. Evaluating device position before generator replacement may be recommended to optimize defibrillation success at generator replacement.
- 28 June 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (7)
Open AccessSuccessful defibrillation testing in patients undergoing elective subcutaneous implantable cardioverter-defibrillator generator replacement
After implantation of a subcutaneous implantable cardioverter-defibrillator (S-ICD), a defibrillation test (DFT) is performed to ensure that the device can effectively detect and terminate the induced ventricular arrhythmia. Data on DFT efficacy at generator replacement are scarce with a limited number of patients and conflicting results. This study evaluates conversion efficacy during DFT at elective S-ICD generator replacement in a large cohort from our tertiary centre. Retrospective data of patients who underwent an S-ICD generator replacement for battery depletion with subsequent DFT between February 2015 and June 2022 were collected. Defibrillation test data were collected from both implant and replacement procedures. PRAETORIAN scores at implant were calculated. Defibrillation test was defined unsuccessful when two conversions at 65 J failed. A total of 121 patients were included. The defibrillation test was successful in 95% after the first and 98% after two consecutive tests. This was comparable with success rates at implant, despite a significant rise in shock impedance (73 ± 23 vs. 83 ± 24 Ω, P < 0.001). Both patients with an unsuccessful DFT at 65 J successfully converted with 80 J. This study shows a high DFT conversion rate at elective S-ICD generator replacement, which is comparable to conversion rates at implant, despite a rise in shock impedance. Evaluating device position before generator replacement may be recommended to optimize defibrillation success at generator replacement.
- Open Access
- 15 December 2022
- Published by Elsevier in Cardiovascular Digital Health Journal
- Vol. 3 (6) , S17-S22
Accuracy and clinical relevance of the single-lead Apple Watch electrocardiogram to identify atrial fibrillation
- 15 December 2022
- Published by Elsevier in Cardiovascular Digital Health Journal
- Vol. 3 (6) , S17-S22
Open AccessAccuracy and clinical relevance of the single-lead Apple Watch electrocardiogram to identify atrial fibrillation