    Simultaneous pulmonary ventilation and perfusion imaging using spectral photon counting CT with xenon and gadolinium-based agents in combination with color K-edge imaging

    by Antoine Robert, Sofia Poletto, Klaus Erhard, Maria Nicole Antonuccio, Christian A. Hernandez, Agnieszka Gutwinska, Ramata Seydou Coulibaly, Florian Davaux, Jean-Baptiste Langlois, Loic Boussel, et al.


  • Open Access

    A Customised Mechanical Ventilator for Combined Oscillometry and X-ray CT Ventilation Imaging

    by D Bizzotto, S Poletto, S Bayat, S A Si-Mohamed, A Robert, R L Dellaca’, C Veneroni

    Combining dedicated X-ray imaging methods, such as K-edge subtraction (KES) or spectral photon-counting CT (SPCCT) imaging, with respiratory oscillometry offers a unique opportunity to investigate the relationship between regional heterogeneity and global lung mechanics with high precision in in vivo models of respiratory pathologies. However, with current technology, these techniques cannot be performed simultaneously during mechanical ventilation without disconnecting the subject from the ventilator. We developed and in vitro validated a mechanical ventilator capable of delivering common pressure-supported modes, estimating respiratory mechanics via oscillometry, and performing rapid gas-mixing switches for SPCCT ventilation imaging, while minimizing tracer (Xenon) gas waste. The system consists of a blower-based ventilator able to switch between open and closed-circuit architecture, enabling fast switching between configurations for Xenon wash-in and wash-out. Bench testing confirmed accurate pressure waveform delivery, precise FiO₂ control, and reliable measurement of respiratory mechanics. The rapid switch between open- and closed-circuit modes minimized Xenon consumption. in vitro tests in a ventilated rabbit model confirmed the capability of enabling oscillometry and clinical SPCCT during mechanical ventilation. This ventilator provides a powerful tool for studying the correlation between regional ventilation defects and global respiratory mechanics, advancing our understanding of pulmonary pathophysiology and supporting the development of personalized, physiology-driven ventilation strategies.


  • Open Access

    A Novel CPAP Device With an Integrated Oxygen Concentrator for Low Resource Countries: In Vitro Validation and Usability Test in Field

    by Poletto Sofia, Zannin Emanuela, Ghilotti Emanuele, Putoto Giovanni, Ichto Jerry, Lochoro Peter, Obizu Moses, Okori Samuel, Corno Matteo, Dellacà Raffaele

    Goal: To develop and validate a novel neonatal noninvasive respiratory support device prototype designed to operate in low-resource settings. Methods: The device integrates a blowerbased ventilator and a portable oxygen concentrator. A novel control algorithm was designed to achieve the desired fraction of inspired oxygen (FiO2) while minimizing power consumption. The accuracy of the delivered FiO2 and the device power consumption were evaluated in vitro, and a formative usability test was conducted in a rural hospital in Uganda. Results: The agreement between the set and delivered FiO2 was high (limit of agreement:5.6÷3.8%). For FiO2 below 60%, the control algorithm reduced the power drain by 50%. The device was also appreciated by intended users. Conclusion: The prototype proved effective in delivering oxygen-enriched continuous positive airway pressure in the absence of compressed air and oxygen, holding promise for a sustainable and effective implementation of neonatal respiratory support in low-resource settings.


  • Late Breaking Abstract - A novel CPAP device with an integrated oxygen concentrator for low-resource countries: in vitro validation and usability test in field

    by Sofia Poletto, Emanuela Zannin, Giovanni Putoto, Moses Obizu, Samuel Okori, Jerry Ictho, Peter Lochoro, Raffaele L. Dellacà

    Background: 98% of under-5 years old children annual deaths occur in low and middle-income countries (LMICs) and are mostly associated with hypoxaemia. Effective implementation of respiratory support could significantly reduce these deaths, but it is limited by the lack of affordable and reliable oxygen supplies. Aims: We developed a respiratory support CPAP device specifically designed for LMICs, integrating a turbine-operated ventilator and an oxygen concentrator. This study aims to: 1)validate the prototype in vitro; 2)test its usability on the field. Methods: A breath simulator mimicking infants breathing pattern of 1.5-4 kg newborns was used for in vitro validation. CPAP was changed from 3 to 15 cmH2O in steps of 3 cmH2O, and the fraction of inspired oxygen (FiO2) from 25% to 70% in 5% steps. CPAP and FiO2 were measured at the airway opening, and compared to the set target. Usability was tested by 15 nurses (Aber, Uganda) who were asked to perform six tasks on a mannequin after receiving a 20-min training. For each task, we recorded number and type of misuses. Participants also filled the Post-Study System Usability Questionnaire (PSSUQ), including 16 items scored from 0 (best) to 7 (worst). Results: The difference between set and measured values was always 2. Participants made a total of 5 mistakes, 3 of which concerning the start-up of the device. The mean PSSUQ score was 1.64±0.49, showing high appreciation for the device. Conclusion: The prototype proved effective in delivering oxygen-enriched CPAP in absence of oxygen sources, and was found to be easy-to-use by healthcare personnel in a resource-limited setting.

  • Bubble CPAP respiratory support devices for infants in low‐resource settings

    by Sofia Poletto, Daniele Trevisanuto, Viraraghavan V. Ramaswamy, Amir Hussein Abubacar Seni, Paul Ouedraogo, Raffaele L. Dellacà, Emanuela Zannin

    Approximately 46% of the 5.2 million annual under‐5 deaths derive from neonatal conditions commonly associated with hypoxemia or acute respiratory distress. It has been estimated that 98% of these deaths occur in low‐ and middle‐income countries (LMICs). Effective implementation of noninvasive respiratory support at all levels of healthcare could significantly reduce neonatal mortality. Several factors limit the widespread and effective implementation of noninvasive respiratory support in LMICs, including inadequate infrastructure, lack of proper instrumentation, shortage of skilled staff, costly disposables, and difficulties in the supply of consumables and spare parts. The aim of this state‐of‐the‐art paper is to provide a detailed evaluation of the commercially available devices providing noninvasive respiratory support in LMICs, focusing on bubblecontinuous positive airway pressure (bCPAP). bCPAP might be administrated using a variety of different commercial devices, including devices specifically designed for LMICs, as well as using self‐made systems. We described all the equipment required for safe and effective implementation of bCPAP, including air and oxygen sourced, pressure‐reducing valves and flowmeters, air‐oxygen blending systems, humidifiers, respiratory support devices, patient circuits, and airway interfaces. Specifically, we critically evaluated the advantages and disadvantages of various existing solutions within the context of low‐resource settings.