Fawen Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fawen Xie has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Longhan Xie
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
3 shared publications - Shuangyuan Huang
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, China
3 shared publications - Tianchao Miao
School of Computer Science and Technology, Henan Institute of Technology, Xinxiang 453003, China
3 shared publications - Jieyu Zhang
School of Mechanical Engineering, Henan Institute of Technology, Xinxiang 453003, China
2 shared publications Li Huang
Department of Rehabilitation Medicine, The Third Affiliated Hospital, Sun Yat-sen Univerity, Guangzhou, China
2 shared publications- Shiman He
Department of Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, China
2 shared publications
Latest Publications
- Open Access
- 14 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (5) , 576
Development of Wearable Wireless Multichannel f-NIRS System to Evaluate Activities
Functional near-infrared spectroscopy is a noninvasive neuroimaging technique that uses optical signals to monitor subtle changes in hemoglobin concentrations within the superficial tissue of the human body. This technology has widespread applications in long-term brain–computer interface monitoring within both traditional medical domains and, increasingly, domestic settings. The popularity of this approach lies in the fact that new single-channel brain oxygen sensors can be used in a variety of scenarios. Given the diverse sensor structure requirements across applications and numerous approaches to data acquisition, the accurate extraction of comprehensive brain activity information requires a multichannel near-infrared system. This study proposes a novel distributed multichannel near-infrared system that integrates two near-infrared light emissions at differing wavelengths (660 nm, 850 nm) with a photoelectric receiver. This substantially improves the accuracy of regional signal sampling. Through a basic long-time mental arithmetic paradigm, we demonstrate that the accompanying algorithm supports offline analysis and is sufficiently versatile for diverse scenarios relevant to the system’s functionality.
- 14 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (5) , 576
Open AccessDevelopment of Wearable Wireless Multichannel f-NIRS System to Evaluate Activities
Functional near-infrared spectroscopy is a noninvasive neuroimaging technique that uses optical signals to monitor subtle changes in hemoglobin concentrations within the superficial tissue of the human body. This technology has widespread applications in long-term brain–computer interface monitoring within both traditional medical domains and, increasingly, domestic settings. The popularity of this approach lies in the fact that new single-channel brain oxygen sensors can be used in a variety of scenarios. Given the diverse sensor structure requirements across applications and numerous approaches to data acquisition, the accurate extraction of comprehensive brain activity information requires a multichannel near-infrared system. This study proposes a novel distributed multichannel near-infrared system that integrates two near-infrared light emissions at differing wavelengths (660 nm, 850 nm) with a photoelectric receiver. This substantially improves the accuracy of regional signal sampling. Through a basic long-time mental arithmetic paradigm, we demonstrate that the accompanying algorithm supports offline analysis and is sufficiently versatile for diverse scenarios relevant to the system’s functionality.
- Open Access
Measurement Approach for the Pose of Flanges in Cabin Assemblies through Distributed Vision
The relative rotation angle between two cabins should be automatically and precisely obtained during automated assembly processes for spacecraft and aircraft. This paper introduces a method to solve this problem based on distributed vision, where two groups of cameras are employed to take images of mating features, such as dowel pins and holes, in oblique directions. Then, the relative rotation between the mating flanges of two cabins is calculated. The key point is the registration of the distributed cameras; thus, a simple and practical registration process is designed. It is assumed that there are rigid and scaling transformations among the world coordinate systems (WCS) of each camera. Therefore, the rigid-correct and scaling-correct matrices are adopted to register the cameras. An auxiliary registration device with known features is designed and moved in the cameras’ field of view (FOV) to obtain the matrix parameters so that each camera acquires traces of every feature. The parameters can be solved using a genetic algorithm based on the known geometric relationships between the trajectories on the registration devices. This paper designs a prototype to verify the method. The precision reaches 0.02° in the measuring space of 340 mm.
Open AccessMeasurement Approach for the Pose of Flanges in Cabin Assemblies through Distributed Vision
The relative rotation angle between two cabins should be automatically and precisely obtained during automated assembly processes for spacecraft and aircraft. This paper introduces a method to solve this problem based on distributed vision, where two groups of cameras are employed to take images of mating features, such as dowel pins and holes, in oblique directions. Then, the relative rotation between the mating flanges of two cabins is calculated. The key point is the registration of the distributed cameras; thus, a simple and practical registration process is designed. It is assumed that there are rigid and scaling transformations among the world coordinate systems (WCS) of each camera. Therefore, the rigid-correct and scaling-correct matrices are adopted to register the cameras. An auxiliary registration device with known features is designed and moved in the cameras’ field of view (FOV) to obtain the matrix parameters so that each camera acquires traces of every feature. The parameters can be solved using a genetic algorithm based on the known geometric relationships between the trajectories on the registration devices. This paper designs a prototype to verify the method. The precision reaches 0.02° in the measuring space of 340 mm.
- Open Access
- 22 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 1776-1785
LiDAR-Based Hand Contralateral Controlled Functional Electrical Stimulation System
Contralateral controlled functional electrical stimulation (CCFES) can induce simultaneous movements in patients’ bilateral hands. It has been clinically proven to be effective in improving hand motor control and dexterity. sEMG and bending sensor-based data gloves for detecting patients’ motor intent have been developed with limitations. sEMG sensor signals are unstable and susceptible to noise. Data gloves composed of bending sensors require complicated calibration and tend to have data drift. In this paper, a LiDAR-based system for hand CCFES is proposed. The method utilized LiDAR to detect the patient’s motion intention without contact in CCFES systems. It has been clinically proven that LiDARs can effectively distinguish the different motion amplitudes of hand gestures as quantitative evaluation sensors of functional electrical stimulation (FES). Training data for classifiers were collected from 9 healthy individuals and 15 stroke patients performing 4 gestures, including hand opening, fist clenching, wrist extension, and wrist flexion. The support vector machine (SVM), linear discriminant analysis (LDA), and k-nearest neighbor (kNN) were verified for their classification performance in offline hand gesture recognition tests. Experiments were also conducted on 6 stroke volunteers to evaluate gestures triggered by FES. The SVM classifier showed excellent classification performance for four hand gestures, with an average F1-score of 0.97±0.05 in offline tests. As for online gesture recognition, an average F1-score of 0.92±0.09 was obtained. In the evaluation experiments, between data from 50% and 100% movement amplitude, paired t-tests showed significant differences. The experimental results indicated that the proposed system showed promise for hand rehabilitation.
- 22 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 1776-1785
Open AccessLiDAR-Based Hand Contralateral Controlled Functional Electrical Stimulation System
Contralateral controlled functional electrical stimulation (CCFES) can induce simultaneous movements in patients’ bilateral hands. It has been clinically proven to be effective in improving hand motor control and dexterity. sEMG and bending sensor-based data gloves for detecting patients’ motor intent have been developed with limitations. sEMG sensor signals are unstable and susceptible to noise. Data gloves composed of bending sensors require complicated calibration and tend to have data drift. In this paper, a LiDAR-based system for hand CCFES is proposed. The method utilized LiDAR to detect the patient’s motion intention without contact in CCFES systems. It has been clinically proven that LiDARs can effectively distinguish the different motion amplitudes of hand gestures as quantitative evaluation sensors of functional electrical stimulation (FES). Training data for classifiers were collected from 9 healthy individuals and 15 stroke patients performing 4 gestures, including hand opening, fist clenching, wrist extension, and wrist flexion. The support vector machine (SVM), linear discriminant analysis (LDA), and k-nearest neighbor (kNN) were verified for their classification performance in offline hand gesture recognition tests. Experiments were also conducted on 6 stroke volunteers to evaluate gestures triggered by FES. The SVM classifier showed excellent classification performance for four hand gestures, with an average F1-score of 0.97±0.05 in offline tests. As for online gesture recognition, an average F1-score of 0.92±0.09 was obtained. In the evaluation experiments, between data from 50% and 100% movement amplitude, paired t-tests showed significant differences. The experimental results indicated that the proposed system showed promise for hand rehabilitation.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1815-1825
Design and Testing of a Dynamic Orthosis to Reduce Glenohumeral Subluxation With Omnidirectional Shoulder Motion
Objective: This paper aimed to develop an orthosis to apply a compensating force to improve the stability of the glenohumeral joint without resisting arm movement. Methods: The proposed orthosis was based on a parallelogram structure to provide a pair of compensating forces to the glenohumeral joint center. Theoretical analysis was used to evaluate the additional moments caused by glenohumeral joint center shifting. Then, an experimental evaluation platform, composed of a torque sensor, a force sensor, and a 3D printed arm, was set up to assess the additional moments and compensating force. Finally, the proposed orthosis was compared with the traditional orthosis to compare the subluxation reduction and the movement restriction when worn by stroke patients. Results: There was only a maximum additional moment of 0.87 Nm for the glenohumeral center shifting. During 3D printed arm movement, the moment correlation coefficient between with and without the proposed orthosis was greater than 0.98, and the compensating force was larger than 90% of the arm weight. The proposed orthosis reduced subluxation by $12.5\pm 3.5$ mm, and the traditional orthosis reduced subluxation by $7.7\pm 2.2$ mm, indicating that the subluxation reduction of the proposed orthosis was more effective ( $p< 0.001$ ). Meanwhile, the proposed orthosis's motion restriction joint was significantly smaller than traditional orthosis ( $p< 0.001$ ). Conclusion: The proposed orthosis provided sufficient gravity compensation without resisting arm movement. Significance: The proposed orthosis can improve the shoulder's stability during shoulder movement, potentially improving the rehabilitation effect of patients with shoulder subluxation.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1815-1825
Design and Testing of a Dynamic Orthosis to Reduce Glenohumeral Subluxation With Omnidirectional Shoulder Motion
Objective: This paper aimed to develop an orthosis to apply a compensating force to improve the stability of the glenohumeral joint without resisting arm movement. Methods: The proposed orthosis was based on a parallelogram structure to provide a pair of compensating forces to the glenohumeral joint center. Theoretical analysis was used to evaluate the additional moments caused by glenohumeral joint center shifting. Then, an experimental evaluation platform, composed of a torque sensor, a force sensor, and a 3D printed arm, was set up to assess the additional moments and compensating force. Finally, the proposed orthosis was compared with the traditional orthosis to compare the subluxation reduction and the movement restriction when worn by stroke patients. Results: There was only a maximum additional moment of 0.87 Nm for the glenohumeral center shifting. During 3D printed arm movement, the moment correlation coefficient between with and without the proposed orthosis was greater than 0.98, and the compensating force was larger than 90% of the arm weight. The proposed orthosis reduced subluxation by $12.5\pm 3.5$ mm, and the traditional orthosis reduced subluxation by $7.7\pm 2.2$ mm, indicating that the subluxation reduction of the proposed orthosis was more effective ( $p< 0.001$ ). Meanwhile, the proposed orthosis's motion restriction joint was significantly smaller than traditional orthosis ( $p< 0.001$ ). Conclusion: The proposed orthosis provided sufficient gravity compensation without resisting arm movement. Significance: The proposed orthosis can improve the shoulder's stability during shoulder movement, potentially improving the rehabilitation effect of patients with shoulder subluxation.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (23) , 22714-22724
Development of a Wireless Multichannel Near-Infrared Spectroscopy Sensor System for Monitoring Muscle Activity
Near-Infrared Spectroscopy (NIRS) technology is a noninvasive technology that can detect the hemoglobin concentration in the shallow tissue of humans in the form of an optical signal and determine the muscle’s activation state based on the change of hemoglobin concentration. It has a broad application prospect in biomedical and physiological signal analysis. There are specific requirements for the structure of NIRS sensors for different application scenarios. The muscle synergy theory explains that body movements are often accompanied by the cooperation of many different muscles. Therefore, a multichannel NIRS system is necessary for motion recognition. This paper presents a distributed multichannel NIRS system. The wireless communication avoids the interference of signal lines, and the equipped upper computer system can display NIRS signals in real-time. Our NIRS sensors have three different wavelengths of near-infrared light (750 nm, 800 nm, 850 nm) and two photodiodes, which can effectively improve the sampling accuracy of the signal. Experimental verification and evaluation prove that our system’s performance and reliability are better than those of other NIRS systems. Finally, cuff occlusion and hand motion experiments demonstrated that blood flow and oxygen consumption are the two main factors that cause hemoglobin concentration changes. We offer a new scheme for NIRS signal analysis that uses the common mode and difference mode of Hb and HbO2, and the results demonstrate its superior performance. In future work, we will discuss the application and effect of the NIRS system in rehabilitation training.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (23) , 22714-22724
Development of a Wireless Multichannel Near-Infrared Spectroscopy Sensor System for Monitoring Muscle Activity
Near-Infrared Spectroscopy (NIRS) technology is a noninvasive technology that can detect the hemoglobin concentration in the shallow tissue of humans in the form of an optical signal and determine the muscle’s activation state based on the change of hemoglobin concentration. It has a broad application prospect in biomedical and physiological signal analysis. There are specific requirements for the structure of NIRS sensors for different application scenarios. The muscle synergy theory explains that body movements are often accompanied by the cooperation of many different muscles. Therefore, a multichannel NIRS system is necessary for motion recognition. This paper presents a distributed multichannel NIRS system. The wireless communication avoids the interference of signal lines, and the equipped upper computer system can display NIRS signals in real-time. Our NIRS sensors have three different wavelengths of near-infrared light (750 nm, 800 nm, 850 nm) and two photodiodes, which can effectively improve the sampling accuracy of the signal. Experimental verification and evaluation prove that our system’s performance and reliability are better than those of other NIRS systems. Finally, cuff occlusion and hand motion experiments demonstrated that blood flow and oxygen consumption are the two main factors that cause hemoglobin concentration changes. We offer a new scheme for NIRS signal analysis that uses the common mode and difference mode of Hb and HbO2, and the results demonstrate its superior performance. In future work, we will discuss the application and effect of the NIRS system in rehabilitation training.