VNVladislav Nikitin

Vladislav Nikitin

*This is an algorithmically generated author record based on publicly available information.

Vladislav Nikitin has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Features of Ovarian Linear Dimensions and Structural Characteristics of Fallopian Tubes Depending on Body Side

    by Anatolii A A. Balandin, Irina A. Balandina, Anna S. Kobeleva, Alina M. Dimidova, Vladislav N. Nikitin

    BACKGROUND: The study of the female reproductive system remains relevant owing to the prevalence of pathologies that exhibit symmetrical and asymmetrical features. AIM: To identify morphological asymmetry patterns in the ovaries and fallopian tubes across their different anatomical regions. MATERIAL AND METHODS: Ultrasound of the ovaries was performed in 23 women aged 30–55 years (mean age: 43.0 ± 0.7 years) without reproductive system pathology and with no more than two pregnancies in history, with the last occurring 5 years prior to the study. The participants were in the premenopausal period and had normal pelvic dimensions. The length, width, and anteroposterior size of each ovary were measured, and ovarian volume was calculated. Micrometric analysis was conducted using postmortem material from 23 women of similar age, without reproductive system pathology, and deceased due to injuries unrelated to abdominal or pelvic organs. The thickness of the mucosal and muscular layers at the intramural part, isthmus, ampulla, and infundibulum of the fallopian tubes were measured. Statistical analysis included Student’s t-test to assess significant mean differences, Pearson’s correlation coefficient to evaluate proportional variability between parameters, and the Mann–Whitney U test to compare independent samples by the value of the fallopian tube parameters. RESULTS: Comparative analysis of the linear dimensions (i.e., length [p = 0.4041], width [p = 0.9443], anteroposterior size [p = 0.9525], and volume [p = 0.4215]) of the ovaries in women during the second period of adulthood based on ultrasound examination revealed larger right-sided measurements, averaging 1.557% greater. Micrometric measurements of the fallopian tubes during cadaveric examination showed a right-sided predominance averaging 0.649%. The Pearson correlation coefficients calculated to assess the proportional relationships between corresponding parameters of the right and left fallopian tubes indicated a strong positive correlation. The minimum correlation coefficient was 0.992 based on ultrasound data and 0.982 based on cadaveric material. Although no significant differences were found between the parameters of both ovaries and both fallopian tubes, percentage-based deviations demonstrated an average right-sided predominance of 0.731%. CONCLUSION: Comparative analysis of the ovarian sizes and micrometric measurements of the fallopian tubes showed a positive correlation between the corresponding right and left parameters.

  • Исследование напряженно-деформированного состояния зубного иммедиат-протеза и сопряженных с ним тканей под действием внешней силы

    by Российский Университет Медицины, Евгений Чижмаков, Сергей Муслов, Анатолий Арутюнов, Наталия Асташина, Пермский Государственный Медицинский Университет Имени Академика Е.а. Вагнера, Владислав Никитин, Пермский Национальный Исследовательский Политехнический Университет, Алексей Никишенко, Конструкторское Бюро Технических Средств Реабилитации

    Целью статьи является анализ напряженно-деформированного состояния (НДС) съемного пластиночного иммедиат-протеза с напечатанным зубным рядом из полиметилметакрилата (ПММА) и базисом из полиэтилентерефталата (ПЭТ) при многофакторных условиях нагружения на основе принципов математического моделирования. При математическом моделировании НДС использовали программное обеспечение Comsol Multiphysics 5,6 (Comsol Inc., США), что предоставило числовые данные для аналитической интерпретации. Рассматривали плоскую 2D-биомеханическую модель, состоящую из напечатанного монолитного зубного ряда и связывающего слоя из ПММА, базиса из ПЭТ, слизистой оболочки протезного поля и костной ткани челюсти. Определены поля напряжений по Мизесу (VM) и деформаций под действием нормальной, наклонной и касательной нагрузок (до 500 Н), локализация их максимальных значений и средняя величина внутри протезной конструкции и вне её (слизистой оболочке и костной ткани). Максимальные значения VM в слизистой оболочке сопоставлены с величиной болевого порога на основе известных литературных данных по алгезиометрии слизистой оболочки рта. Выполнена оценка критической длины микротрещины (КДМ) по Гриффитсу, которая ведет к образованию магистральной трещины с последующим хрупким разрушением конструкции. Методом фазового поля вычислена вероятность трещинообразования в рассмотренной модели ортопедической конструкции под действием статической нагрузки. Показано, что поломки при использовании иммедиат-протезов с напечатанными зубами из ПММА и базисом из ПЭТ могут быть обусловлены эффектом перегрузки областей базиса и вызваны процессом деформации внутри протезной конструкции. Максимальные напряжения в элементах протеза при нормальной нагрузке составили 5,8 МПа, при тангенциальной – 79 МПа, деформации – 0,01 и 0,47 мм соответственно. Величина болевого порога слизистой оболочки рта (0,35 МПа) не достигается при нормальных усилиях (0°), однако возникает при наклонных нагрузках (45°) выше 230 Н и касательных (90°) 170 Н. Коэффициент неоднородности НДС модели съемного пластиночного иммедиат-протеза 8,6. Критическая длина микротрещины по Гриффитсу lкрит = 1,9…2,7 мкм. Методом фазового поля Comsol Multiphysics установлено, что вероятность образования крупной трещины в базисе протеза составила 6·10–3; 0,35; 0,73 % для нормальной, наклонной и сдвиговой нагрузки 500 Н, что является достаточным значением для эксплуатации съемных пластиночных протезов с напечатанными зубами из ПММА и базисом из ПЭТ в течение гарантийного срока эксплуатации.

  • Stress-strain state of dental immediate prosthesis and associated tissue under the influence of external force

    by Russian University of Medicine, Evgeniy Chizhmakov, Sergey Muslov, Anatolij Arutyunov, Natalia Astashina, Perm State Medical University named after Academician E.A. Wagner, Vladislav Nikitin, Perm National Research Polytechnic University, Aleksey Nikishenko, Design Bureau of Technical Means of Rehabilitation

    Purpose: to analyze the stress-strain state (SSS) of a removable plate immediate denture with a printed dentition made of polymethyl methacrylate (PMMA) and a polyethylene terephthalate (PET) base under multifactor loading conditions based on the principles of mathematical modeling. Materials and methods: For mathematical modeling of SSS, Comsol Multiphysics 5.6 software (Comsol Inc., USA) was used, which provided numerical data for analytical interpretation. We considered a flat 2D model consisting of a printed monolithic dentition and a PMMA bonding layer, a PET base, the mucous membrane of the prosthetic field and jaw bone tissue. Results: The fields of von Mises stresses (VM) and deformations under the influence of normal, oblique and tangential loads (up to 500 N), the localization of their maximum values and the average value inside the prosthetic structure, mucous membrane and bone tissue were determined. The maximum values of VM in the mucous membrane are compared with the pain threshold based on known literature data on algesiometry of the oral mucosa. An assessment was made of the critical length of microcracks (CLM) according to Griffiths, which lead to the formation of a main crack followed by brittle fracture of the structure base. Using the phase field method, the probability of crack formation in the considered model of an orthopedic structure under the influence of static loads of various magnitudes and directions was calculated. Conclusions: Using the method of mathematical modeling of SSS, it was shown that failures when using immediate dentures with printed teeth made of PMMA and a PET base can be caused by the effect of overloading the areas of the base and caused by the deformation process inside the prosthetic structure. The maximum stress in the prosthetic elements was 79.7 MPa and deformation – 0.47 mm. The pain threshold of the oral mucosa is higher than the highest stress value in the prosthetic bed according to Mises (0.002 MPa) for normal load of 500 N. The SSS heterogeneity coefficient of the removable plate immediate prosthesis model is 8.6. The critical length of a microcrack according to Griffiths is lcrit = 1.9...2.7 µm. Using the Comsol Multiphysics phase field method, it was established that the probability of the formation of a large crack in the base of the prosthesis was 6·10–3 %, 0.36 %,0.73 % for a normal, inclined and shear load of 500 N, which is a sufficient value for the operation of removable laminar dentures with printed teeth from PMMA and a PET base during the warranty period.

  • Упругая линейная, билинейная, нелинейная экспоненциальная и гиперупругие модели кожи.

    by Московский Государственный Медико-Стоматологический Университет Имени А.и. Евдокимова, Сергей Муслов, Сергей Перцов, Научно-Исследовательский Институт Нормальной Физиологии Имени П.к. Анохина, Евгений Чижмаков, Наталия Асташина, Пермский Государственный Медицинский Университет Имени Академика Е.а. Вагнера, Владислав Никитин, Пермский Национальный Исследовательский Политехнический Университет, Сергей Арутюнов

    Результаты одноосных механических испытаний, проведенных на коже спины верхней, средней и нижней её части in vitro были сопоставлены с линейной, билинейной и нелинейной экспоненциальной, а также пятью гиперупругими моделями. Результаты показали, что деформационные свойства тканей зависят от её местоположения и наилучшим образом описываются экспоненциальной функцией σ = a·(exp(b·ε) – 1), где a и b – материальные константы, зависящие от локализации и направленности образцов по отношению к линиям Лангера. Определены параметры упругих дифференциальных модулей E(ε) тканей (минимальные, средние и максимальные значения). Дифференциальный модуль упругости является инкрементальным (возрастающим с деформацией от 8.57 до 154.44 МПа), а уравнение регрессии имеет вид E = a·b·exp(b·ε) (r = 0.998) и весьма точно характеризует его упругое поведение. Модуль Юнга образцов, параллельных линиям Лангера выше, чем в косом (45º) и поперечном направлении, а в средней части спины больше, чем в верхней и нижней части (Eср(ε) = 56.59, 35.76, 21.74 МПа, соответственно), коэффициент упругой анизотропии равен 3.49. Рассмотрены линейная (r = 0.965) и билинейная (r = 0.967) упругие модели и определены численные значения параметров моделей. Для изучения гиперупругих свойств кожи были использованы: неогуковская, Муни–Ривлина, Огдена, полиномиальная и Веронда– Вестманн (V-W) феноменологические модели. Расчеты производились в системе компьютерной алгебры Mathcad 13.0 и многоцелевом пакете программ ANSYS 2022 R2. Определены параметры моделей и теснота корреляционной связи между опытными и расчетными данными. Коэффициент корреляции использовался как критерий соответствия моделей и реальных свойств тканей. Наибольшую корреляцию с экспериментальными значениями продемонстрировала полиномиальная модель (r = 0.9997) и модель Веронда–Вестманн (r = 0.999), наименьшую – неогуковская (r = 0.935). Значения модулей Юнга и других упругих и гиперупругих характеристик тканей сравнивались для изучения факторов, влияющих на механическое поведение кожи спины человека.


  • Elastic linear, bilinear, nonlinear exponential and hyperelastic skin models

    by Evdokimov Moscow State University of Medicine and Dentistry, Sergey Muslov, Sergey Pertsov, Anokhin Research Institute of Normal Physiology, Evgeniy Chijmakov, Perm State Medical University named after Academician E.A. Wagner, Nataliia Astashina, Perm National Research Polytechnic University, Vladislav Nikitin, Sergey Arutyunov

    Linear, bilinear, exponential and hyperelastic models of human back skin are ana-lyzed. The results showed that the elastic properties of tissues depend on its location and are best described by exponential functions σ = a·(exp(b·ε) – 1), where a and b are material constants that depend on the localization and orientation of the samples along relation to the Langer lines. The parameters of elastic differential moduli E(ε) of tissues (minimum, average and maximum values) are determined. The differential modulus of elasticity is incremental (increasing with strain from 8.57 to 154.44 MPa), and the regres-sion equation has the form E = a·b·exp(b·ε) (r = 0.998) and very accurately characterizes its elastic behavior. The Young's modulus of samples parallel to the Langer lines is higher than in the oblique (45º) and transverse directions, and in the middle part of the back is higher than in the upper and lower parts (Eav(ε) = 56.59, 35.76, 21.74 MPa, respectively), the elastic anisotropy coefficient is 3.49. Linear (r = 0.965) and bilinear (r = 0.967) elastic models are considered, and the numerical values of the model parameters are determined. To study the hyperelastic properties of the skin, neo-Hooke, Mooney-Rivlin, Ogden, polynomial and Veronda–Westmann (V–W) phenomenological models were used. The calculations were carried out using the Mathcad 13.0 computer algebra system and the ANSYS 2022 R2 multipurpose software package. The parameters of the models and the closeness of the correlation between experimental and calculated data are determined. The correlation coefficient was used as a criterion for the correspondence between mod-els and real properties of tissues. The polynomial model (r = 0.9997) and the Veronda–Westmann model (r = 0.999) demonstrated the highest correlation with the experimental values, the Ogden model (r = 0.891) and the neo-Hookean one (r = 0.935) demonstrated the lowest correlation with the experimental values. The values of Young's moduli and other elastic and hyperelastic characteristics of tissues were compared to study the factors influencing the mechanical behavior of human back skin.


  • Open Access

    Pathophysiology and biomechanics of stretch-induced peripheral nerve injuries

    by Yulia V. Karakulova, Gayane Z. Kloyan, Sergey V. Muravev, Ivan D. Shitoev, Vladislav N. Nikitin, Maria D. Ivanova, Клоян Гаянэ Зурабиевна

    Objective: to investigate pathophysiology and biomechanics of the nerve stretching and to form a biomechanical model of a nerve stretch injury. Materials and methods. We analyzed and summarized the data from open access sources (eLibrary, Scopus, Web of Science, PubMed) with unlimited search depth. A search was performed using the following keywords: растяжение нерва (English: nerve stretching), stretching nerve, biomechanical nerve stretching, nerve stretching injury. Results. Here are presented key historical information and biochemical, neurophysiological, and biomechanical events related to a nerve stretch injury. Objective experimental data on the nerve stretching process are summarized. Conclusions. A nerve is a heterogeneous elastic cord, which can be slightly stretched under physiological conditions due to the involvement of its sheath structures. In a stretched nerve, ischemic lesions have an early onset and further become irreversible. Nerve conduction disorders occur, resulting in a severe neurological deficit. When the nerve is stretched by more than a third, it ruptures and the sequence in which fragmented neural structures occur during nerve tension remains unclear.


  • Application of Decisions' Roots for Data Analysis on Example of Dataset with Magnetic Susceptibility Values of the Brain Veins and the Alzheimer's Disease

    by Leonid V. Kozhemyakin, Aleksandr O. Alekseev, Vladislav N. Nikitin

    In this paper, an attempt was made to approximate medical data and establish the relationship between the magnetic susceptibility values of the cerebral veins and the Alzheimer's disease in the form of integrated rating mechanisms, or as they are also called recently “decisions' roots”. Quantitative susceptibility mapping indicators are used as medical data. These data allowed us to obtain the value of magnetic susceptibility and provides information on oxygen metabolism. This information is important in assessing neuronal metabolism. Significant factors (the values of the magnetic susceptibility of the cerebral veins) were determined using the methods of system-cognitive analysis. These factors can affect the cognitive state of the patient. Discrete function was constructed using the decision roots identification algorithm. This function described with high reliability the initial set of research data (values of the magnetic susceptibility of the cerebral veins) on the condition of patients for the presence of Alzheimer's disease.