Taku Kuramoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Taku Kuramoto has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Shinya Takarabe
Department of Radiological Technology, Faculty of Health Sciences, Kobe Tokiwa University, 2-6-2 Otanicho, Nagata-ku, Kobe 653-0838, Japan
5 shared publications Toyoyuki Kato
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
5 shared publicationsYusuke Shibayama
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
5 shared publicationsShinya Takarabe
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
4 shared publicationsYoshiyuki Kitamura
Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
3 shared publicationsYuzo Yamasaki
Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
3 shared publications
Latest Publications
- 31 March 2026
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 57 (3) , 102340
Advancing chest radiograph interpretation training via e-learning: A study on radiography students
- 31 March 2026
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 57 (3) , 102340
Advancing chest radiograph interpretation training via e-learning: A study on radiography students
- Open Access
- 1 January 2026
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 82 (5) , 26-1639
A Comprehensive Evaluation of the Performance of Large Language Models on the Japanese National Examination for Radiological Technologists
【目的】本研究の目的は,診療放射線技師国家試験の問題に対し,複数の大規模言語モデル(LLM)がどの程度の正答能力を有するかを評価し,特性を明らかにすることである.【方法】12年分の国家試験問題(不適切問題等を除く)を使用し,5種類のLLM(ChatGPT-3.5, Gemini 2.5 Flash, Gemini 2.5 Pro, Copilot, Claude Sonnet 4)に回答させた.全問題と問題形式ごとに分類して各LLMで正答率を算出した.【結果】総正答率および多くの科目別の正答率でGemini 2.5 Proが最も高い正答率を示した.問題形式ごとでもGemini 2.5 Proは高い正答率が高い傾向を示したが,他のLLMの正答率は問題形式で異なる傾向を示した.【結語】LLMは診療放射線技師国家試験において一定の正答能力を有することが示されたが,特に図を含む問題の解釈能力には課題が残ることも明らかになった.
- 1 January 2026
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 82 (5) , 26-1639
Open AccessA Comprehensive Evaluation of the Performance of Large Language Models on the Japanese National Examination for Radiological Technologists
【目的】本研究の目的は,診療放射線技師国家試験の問題に対し,複数の大規模言語モデル(LLM)がどの程度の正答能力を有するかを評価し,特性を明らかにすることである.【方法】12年分の国家試験問題(不適切問題等を除く)を使用し,5種類のLLM(ChatGPT-3.5, Gemini 2.5 Flash, Gemini 2.5 Pro, Copilot, Claude Sonnet 4)に回答させた.全問題と問題形式ごとに分類して各LLMで正答率を算出した.【結果】総正答率および多くの科目別の正答率でGemini 2.5 Proが最も高い正答率を示した.問題形式ごとでもGemini 2.5 Proは高い正答率が高い傾向を示したが,他のLLMの正答率は問題形式で異なる傾向を示した.【結語】LLMは診療放射線技師国家試験において一定の正答能力を有することが示されたが,特に図を含む問題の解釈能力には課題が残ることも明らかになった.
- 28 May 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- p. 1-9
Improvement of lung nodule visibility using one-shot dual-energy subtraction chest radiography with dual-layer flat-panel detector: a phantom study
Chest x-ray imaging is widely used for the diagnosis of chest diseases but has low sensitivity for detecting pulmonary nodules due to anatomical overlaps. Dual-energy subtraction (DES) imaging can improve nodule visibility by reducing bone obscuration. This study aims to evaluate the image quality of a new one-shot DES (OSDES) system with a dual-layer flat-panel detector compared with the widely used two-shot DES (TSDES) system. Chest phantom images of various simulated nodules (8,10, and 12 mm) were acquired using both DES systems at several exposure doses, lung regions, and two types of body sizes (standard and large). Independent observers evaluated the visibility of the nodules under each condition using visual grading analysis scores (VGASs). The VGASs of OSDES images were significantly higher than those of TSDES images across all nodule sizes, lung regions, exposure doses, and body sizes, except for the standard chest phantom with a 10-mm nodule and without ribs. In particular, the VGAS of an 8-mm nodule in the region with one overlapping rib of the standard sized phantom was 2.46 with OSDES and 1.03 with TSDES, with the visibility of the nodule being significantly improved with the OSDES system. Thus, the OSDES system, using a dual-layer flat-panel detector and one exposure, offers superior visibility of pulmonary nodules with reduced dose compared with the TSDES system, suggesting its potential for improved clinical diagnosis without motion artifacts.
- 28 May 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- p. 1-9
Improvement of lung nodule visibility using one-shot dual-energy subtraction chest radiography with dual-layer flat-panel detector: a phantom study
Chest x-ray imaging is widely used for the diagnosis of chest diseases but has low sensitivity for detecting pulmonary nodules due to anatomical overlaps. Dual-energy subtraction (DES) imaging can improve nodule visibility by reducing bone obscuration. This study aims to evaluate the image quality of a new one-shot DES (OSDES) system with a dual-layer flat-panel detector compared with the widely used two-shot DES (TSDES) system. Chest phantom images of various simulated nodules (8,10, and 12 mm) were acquired using both DES systems at several exposure doses, lung regions, and two types of body sizes (standard and large). Independent observers evaluated the visibility of the nodules under each condition using visual grading analysis scores (VGASs). The VGASs of OSDES images were significantly higher than those of TSDES images across all nodule sizes, lung regions, exposure doses, and body sizes, except for the standard chest phantom with a 10-mm nodule and without ribs. In particular, the VGAS of an 8-mm nodule in the region with one overlapping rib of the standard sized phantom was 2.46 with OSDES and 1.03 with TSDES, with the visibility of the nodule being significantly improved with the OSDES system. Thus, the OSDES system, using a dual-layer flat-panel detector and one exposure, offers superior visibility of pulmonary nodules with reduced dose compared with the TSDES system, suggesting its potential for improved clinical diagnosis without motion artifacts.
- 25 November 2023
- Published by Elsevier in Academic Radiology
- Vol. 31 (5) , 2118-2127
Correlation Between Contrast-Detail Analysis and Clinical Image Quality Assessment of Intrapulmonary Lesions in Dual-Energy Subtraction Chest Radiography Using the Two-Shot Method: A Phantom Study
- 25 November 2023
- Published by Elsevier in Academic Radiology
- Vol. 31 (5) , 2118-2127
Correlation Between Contrast-Detail Analysis and Clinical Image Quality Assessment of Intrapulmonary Lesions in Dual-Energy Subtraction Chest Radiography Using the Two-Shot Method: A Phantom Study
- 16 December 2022
- Published by Elsevier in Radiography
- Vol. 29 (1) , 240-246
Effect of high- and low-energy entrance surface dose allocation ratio for two-shot dual-energy subtraction imaging on low-contrast resolution
- 16 December 2022
- Published by Elsevier in Radiography
- Vol. 29 (1) , 240-246
Effect of high- and low-energy entrance surface dose allocation ratio for two-shot dual-energy subtraction imaging on low-contrast resolution
- 23 February 2022
- Published by Elsevier in Physica Medica
- Vol. 95, 176-181
Is the image quality of conventional chest radiography obtained from a two-layer flat panel detector affected by the internal structure of the detector?
- 23 February 2022
- Published by Elsevier in Physica Medica
- Vol. 95, 176-181
Is the image quality of conventional chest radiography obtained from a two-layer flat panel detector affected by the internal structure of the detector?
- 20 July 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (04) , 043501-11
Effect of beam quality and readout direction in the edge profile on the modulation transfer function of photostimulable phosphor systems via the edge method
Purpose: The objective of this study was to investigate the effects of (i) the difference in the beam qualities on the presampled modulation transfer function (MTF) using the edge method and (ii) the readout direction of the edge profile for the photostimulable phosphor (PSP) system. Approach: The International Electrotechnical Commission (IEC) defined a technique using the “radiation qualities based on a phantom made up of an aluminum added filter” (RQA). A general radiographic system with a tube voltage of 50 kV and 9.7 mm of additional aluminum filtration was used to conform the x-ray to the IEC-specified beam quality definition RQA3. Additionally, we employed two different beams with tube voltages of 60 and 70 kV using a dental x-ray unit. The MTF was measured in the readout direction from low-to-high exposure regions and vice versa with respect to the scanning and subscanning directions of the PSP system. Results: The difference in the 50%MTF value for all directions between 60 and 70 kV averaged less than 0.05. The 50%MTF of RQA3 was on average 0.2 lower than the value for 60 kV for each direction. For all beam qualities, no difference was observed between the MTFs measured in the readout direction from the low-to-high exposure regions and vice versa. Conclusions: The MTFs, measured using the dental x-ray unit, were unaffected by the tube voltage, and they were slightly higher than those measured using the RQA3. Furthermore, the MTF was unaffected by the differences in the readout directions of the edge profile.
- 20 July 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (04) , 043501-11
Effect of beam quality and readout direction in the edge profile on the modulation transfer function of photostimulable phosphor systems via the edge method
Purpose: The objective of this study was to investigate the effects of (i) the difference in the beam qualities on the presampled modulation transfer function (MTF) using the edge method and (ii) the readout direction of the edge profile for the photostimulable phosphor (PSP) system. Approach: The International Electrotechnical Commission (IEC) defined a technique using the “radiation qualities based on a phantom made up of an aluminum added filter” (RQA). A general radiographic system with a tube voltage of 50 kV and 9.7 mm of additional aluminum filtration was used to conform the x-ray to the IEC-specified beam quality definition RQA3. Additionally, we employed two different beams with tube voltages of 60 and 70 kV using a dental x-ray unit. The MTF was measured in the readout direction from low-to-high exposure regions and vice versa with respect to the scanning and subscanning directions of the PSP system. Results: The difference in the 50%MTF value for all directions between 60 and 70 kV averaged less than 0.05. The 50%MTF of RQA3 was on average 0.2 lower than the value for 60 kV for each direction. For all beam qualities, no difference was observed between the MTFs measured in the readout direction from the low-to-high exposure regions and vice versa. Conclusions: The MTFs, measured using the dental x-ray unit, were unaffected by the tube voltage, and they were slightly higher than those measured using the RQA3. Furthermore, the MTF was unaffected by the differences in the readout directions of the edge profile.
- 1 January 2021
- Published by Elsevier in Physica Medica
- Vol. 81, 302-307
X-ray dose reduction using additional copper filtration for dental cone beam CT
- 1 January 2021
- Published by Elsevier in Physica Medica
- Vol. 81, 302-307
X-ray dose reduction using additional copper filtration for dental cone beam CT
- 1 September 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (6) , 20190378
Effect of differences in pixel size on image characteristics of digital intraoral radiographic systems: a physical and visual evaluation
Objectives: To quantify and validate the effect of pixel size on a digital intraoral radiographic system according to International Electrotechnical Commission standards through physical and visual evaluations. Methods: The digital intraoral radiographic system used was the photostimulable phosphor imaging plate and scanner system. The system had three image capture modes: high-speed (HS), high-resolution (HR), and super high-resolution (SHR) with different pixels. The physical characteristics of the system were evaluated using presampled modulation transfer function (MTF) and the normalized noise power spectrum (NNPS). An aluminum (Al) step phantom with different depths of holes was used to acquire images under various exposure conditions. The average number of perceptible holes from all steps was plotted against each exposure dose. The results were compared to analyze the effects of pixel size on image quality of intraoral radiographs. Results: The MTF was slightly higher with SHR than with HR and HS. The NNPS with SHR showed about a 40% decrease in magnitude compared to HS. The total number of perceptible holes in the Al step phantom was higher with SHR than with HS and HR in all exposure conditions. Conclusions: The MTF and NNPS obtained with different pixel size could be quantified by physical evaluation, and the differences were visually validated with Al step phantom. The SHR mode has the potential to decrease the radiation dose without compromising the image quality.
- 1 September 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (6) , 20190378
Effect of differences in pixel size on image characteristics of digital intraoral radiographic systems: a physical and visual evaluation
Objectives: To quantify and validate the effect of pixel size on a digital intraoral radiographic system according to International Electrotechnical Commission standards through physical and visual evaluations. Methods: The digital intraoral radiographic system used was the photostimulable phosphor imaging plate and scanner system. The system had three image capture modes: high-speed (HS), high-resolution (HR), and super high-resolution (SHR) with different pixels. The physical characteristics of the system were evaluated using presampled modulation transfer function (MTF) and the normalized noise power spectrum (NNPS). An aluminum (Al) step phantom with different depths of holes was used to acquire images under various exposure conditions. The average number of perceptible holes from all steps was plotted against each exposure dose. The results were compared to analyze the effects of pixel size on image quality of intraoral radiographs. Results: The MTF was slightly higher with SHR than with HR and HS. The NNPS with SHR showed about a 40% decrease in magnitude compared to HS. The total number of perceptible holes in the Al step phantom was higher with SHR than with HS and HR in all exposure conditions. Conclusions: The MTF and NNPS obtained with different pixel size could be quantified by physical evaluation, and the differences were visually validated with Al step phantom. The SHR mode has the potential to decrease the radiation dose without compromising the image quality.