Alexandra Stredanska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexandra Stredanska has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- David Nečas
Department of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
2 shared publications - Jakub Suchánek
Department of Dentistry, Charles University, Faculty of Medicine in Hradec Kralove and University Hospital Hradec Kralove, 500 05 Hradec Kralove, Czech Republic
2 shared publications - Kristina Nešporová
Contipro a.s., 56102 Dolni Dobrouc, Czech Republic
2 shared publications - Lucy Vojtová
Advanced Biomaterials Group, Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
2 shared publications - Martin Vrbka
Biotribology Research Group, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
2 shared publications - David Rebenda
Department of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 15 September 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (38) , 44147-44161
Biomimetic pHEMA Hydrogels as an Alternative Cartilage-like Model Material for Biotribological Evaluations
Poly-(vinyl alcohol) (PVA) has been widely explored as a model material for articular cartilage (AC) in biotribological evaluations. However, PVA hydrogels prepared by freeze-thawing or cast-drying methods have limitations in precisely controlling their elasticity parameters and may require reinforcement to enhance their mechanical performance and change their transparency, required in some tribological measurement setups by using fluorescence methods. To overcome these issues, poly-(hydroxyethyl methacrylate) (pHEMA) hydrogels have been introduced as alternatives. In our study, pHEMA hydrogels synthesized using free-radical polymerization with blue light under two different atmospheres (nitrogen N2 and air) were compared with natural samples of articular bovine cartilage. The optical, mechanical, swelling, and tribological properties demonstrate the superior properties of pHEMA, which may result in the replacement of the currently used PVA-based model in future studies. Synthesis under a nitrogen atmosphere (pHEMA N 2) resulted in the formation of smooth-surfaced hydrogels, whereas synthesis under a laboratory atmosphere (pHEMA air) resulted in the formation of wrinkled-surfaced hydrogels. The swelling of both the hydrogels and AC followed first-order kinetics. Pin-on-plate biotribology measurements showed that the coefficient of friction of the wrinkled-surface hydrogels resembled that of AC. Our results showed that pHEMA-based hydrogels are suitable biotribological AC models for a better understanding of the biological functions of bovine AC. This knowledge brings new insights into cartilage complex mechanisms and might be applied in both biomedical and engineering applications.
- 15 September 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (38) , 44147-44161
Open AccessBiomimetic pHEMA Hydrogels as an Alternative Cartilage-like Model Material for Biotribological Evaluations
Poly-(vinyl alcohol) (PVA) has been widely explored as a model material for articular cartilage (AC) in biotribological evaluations. However, PVA hydrogels prepared by freeze-thawing or cast-drying methods have limitations in precisely controlling their elasticity parameters and may require reinforcement to enhance their mechanical performance and change their transparency, required in some tribological measurement setups by using fluorescence methods. To overcome these issues, poly-(hydroxyethyl methacrylate) (pHEMA) hydrogels have been introduced as alternatives. In our study, pHEMA hydrogels synthesized using free-radical polymerization with blue light under two different atmospheres (nitrogen N2 and air) were compared with natural samples of articular bovine cartilage. The optical, mechanical, swelling, and tribological properties demonstrate the superior properties of pHEMA, which may result in the replacement of the currently used PVA-based model in future studies. Synthesis under a nitrogen atmosphere (pHEMA N 2) resulted in the formation of smooth-surfaced hydrogels, whereas synthesis under a laboratory atmosphere (pHEMA air) resulted in the formation of wrinkled-surfaced hydrogels. The swelling of both the hydrogels and AC followed first-order kinetics. Pin-on-plate biotribology measurements showed that the coefficient of friction of the wrinkled-surface hydrogels resembled that of AC. Our results showed that pHEMA-based hydrogels are suitable biotribological AC models for a better understanding of the biological functions of bovine AC. This knowledge brings new insights into cartilage complex mechanisms and might be applied in both biomedical and engineering applications.
- Open Access
- 16 April 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (4) , 184
Optimizing Hyaluronan-Based Lubricants for Treating Thoracolumbar Fascia Pathologies: Insights from Tribological and Pharmacokinetic Studies
In a world where the incidence of non-specific lower back pain (LBP) is steadily increasing, researchers are still searching for effective solutions for patients. Hyaluronic acid (HA) viscosupplementation is commonly used to restore lubrication in osteoarthritis (OA) and other medical applications, but its rapid metabolism limits efficacy. This study evaluates whether an HA derivative can replace native HA for the treatment of non-specific LBP while maintaining or enhancing its frictional properties and improving in vivo stability. Six HA-based lubricants, both native and derivatized, were tested in a tribological rabbit fascia model and a new synthetic model. Reduced HA derivative showed better tribological properties and longer in vivo residence time compared to native HA, as demonstrated in pharmacokinetic studies in rabbits. The 316 kDa HA and reduced HA exhibited the most stable tribological properties, which were influenced by their molecular weight and concentration. These findings suggest that both native and reduced HA are promising viscosupplements for intrafascial injection in the treatment of LBP, with reduced HA potentially enhancing effectiveness through a prolonged effect.
- 16 April 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (4) , 184
Open AccessOptimizing Hyaluronan-Based Lubricants for Treating Thoracolumbar Fascia Pathologies: Insights from Tribological and Pharmacokinetic Studies
In a world where the incidence of non-specific lower back pain (LBP) is steadily increasing, researchers are still searching for effective solutions for patients. Hyaluronic acid (HA) viscosupplementation is commonly used to restore lubrication in osteoarthritis (OA) and other medical applications, but its rapid metabolism limits efficacy. This study evaluates whether an HA derivative can replace native HA for the treatment of non-specific LBP while maintaining or enhancing its frictional properties and improving in vivo stability. Six HA-based lubricants, both native and derivatized, were tested in a tribological rabbit fascia model and a new synthetic model. Reduced HA derivative showed better tribological properties and longer in vivo residence time compared to native HA, as demonstrated in pharmacokinetic studies in rabbits. The 316 kDa HA and reduced HA exhibited the most stable tribological properties, which were influenced by their molecular weight and concentration. These findings suggest that both native and reduced HA are promising viscosupplements for intrafascial injection in the treatment of LBP, with reduced HA potentially enhancing effectiveness through a prolonged effect.
- Open Access
- 5 May 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 155, 106566
Understanding frictional behavior in fascia tissues through tribological modeling and material substitution
- 5 May 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 155, 106566
Open AccessUnderstanding frictional behavior in fascia tissues through tribological modeling and material substitution