Yanchao Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanchao Zhao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Wei Xu
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
4 shared publications - Weichao Guo
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Xinjun Sheng
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Xiangyang Zhu
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications Xinjun Sheng
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications- Xu Shi
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications
Latest Publications
- 5 September 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (9) , 6765-6774
Strain-Insensitive, Crosstalk-Suppressed, Ultrawide-Linearity Iontronic Tactile Skin from a Synergistic Segment-Embedded Strategy
Tactile sensing arrays play a crucial role in human-machine interaction, robotics, and artificial intelligence by enabling the perception of physical stimuli on robotic surfaces or human skin. However, skin-attachable sensor arrays still suffer from strain interference and signal crosstalk under stretching or bending, particularly on curved or deformable surfaces. Here, we present a stretchable tactile array that is both strain-insensitive and crosstalk-suppressed, achieved via a hierarchically segmented design that mitigates lateral and vertical deformations synergistically. By tessellating hard and compliant elements within encapsulation layers, stretch deformation in the sensing region is reduced by 79%, and the overall mean stress is decreased by over 90%. Multilevel segmented spacers are proposed to provide vertical support while maintaining stretchability. These synergistic designs achieve comprehensive strain insensitivity (75% stretching insensitivity and bending insensitivity) and ultralow crosstalk (31.82 dB). Furthermore, iontronic porous foams are introduced to endow sensing pixels with high linearity (R2 = 0.985) and sensitivity (2.812 kPa-1). We demonstrate accurate tactile information acquisition on soft, curved human fingers and showcase the array's potential for multi-attribute object recognition.
- 5 September 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (9) , 6765-6774
Strain-Insensitive, Crosstalk-Suppressed, Ultrawide-Linearity Iontronic Tactile Skin from a Synergistic Segment-Embedded Strategy
Tactile sensing arrays play a crucial role in human-machine interaction, robotics, and artificial intelligence by enabling the perception of physical stimuli on robotic surfaces or human skin. However, skin-attachable sensor arrays still suffer from strain interference and signal crosstalk under stretching or bending, particularly on curved or deformable surfaces. Here, we present a stretchable tactile array that is both strain-insensitive and crosstalk-suppressed, achieved via a hierarchically segmented design that mitigates lateral and vertical deformations synergistically. By tessellating hard and compliant elements within encapsulation layers, stretch deformation in the sensing region is reduced by 79%, and the overall mean stress is decreased by over 90%. Multilevel segmented spacers are proposed to provide vertical support while maintaining stretchability. These synergistic designs achieve comprehensive strain insensitivity (75% stretching insensitivity and bending insensitivity) and ultralow crosstalk (31.82 dB). Furthermore, iontronic porous foams are introduced to endow sensing pixels with high linearity (R2 = 0.985) and sensitivity (2.812 kPa-1). We demonstrate accurate tactile information acquisition on soft, curved human fingers and showcase the array's potential for multi-attribute object recognition.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (5) , 3735-3745
Stochastic Force-Closure Grasp Synthesis for Unknown Objects Using Proximity Perception
Proximity perception is a promising technology that provides near-field information valuable for robotics. To improve the functionality of proximity perception in anthropomorphic hands, we propose a novel stochastic force-closure grasp synthesis (SFCGS) that finds robust grasps insensitive to object uncertainty introduced by the lack of explorations and perception noise. Specifically, we propose a dual-mode perception system comprised of five flexible capacitive dual-mode (proximity and pressure) sensors. Using the Gaussian process, we explore unknown objects with proximity perception and approximate their signed distance function. The SFCGS formulates the problem of finding the probabilistically optimal grasps as minimizing the separation probability of the origin and stochastic grasp wrench space. In addition, a dual-mode reactive controller is presented to improve the grasping success rate. The results from simulation experiments indicate that proximity perception can reduce the reconstruction error by 4.53 cm compared to tactile perception. Furthermore, the newly introduced SFCGS can yield more uncertainty-insensitive grasps than the traditional force-closure approach. In real-world experiments, the proposed approach achieves a considerable 13.4% improvement in success rate over benchmark methods. The outcomes of this study are significant in promoting the application of proximity perception in robot hand-arm systems and upper-limb prostheses.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (5) , 3735-3745
Stochastic Force-Closure Grasp Synthesis for Unknown Objects Using Proximity Perception
Proximity perception is a promising technology that provides near-field information valuable for robotics. To improve the functionality of proximity perception in anthropomorphic hands, we propose a novel stochastic force-closure grasp synthesis (SFCGS) that finds robust grasps insensitive to object uncertainty introduced by the lack of explorations and perception noise. Specifically, we propose a dual-mode perception system comprised of five flexible capacitive dual-mode (proximity and pressure) sensors. Using the Gaussian process, we explore unknown objects with proximity perception and approximate their signed distance function. The SFCGS formulates the problem of finding the probabilistically optimal grasps as minimizing the separation probability of the origin and stochastic grasp wrench space. In addition, a dual-mode reactive controller is presented to improve the grasping success rate. The results from simulation experiments indicate that proximity perception can reduce the reconstruction error by 4.53 cm compared to tactile perception. Furthermore, the newly introduced SFCGS can yield more uncertainty-insensitive grasps than the traditional force-closure approach. In real-world experiments, the proposed approach achieves a considerable 13.4% improvement in success rate over benchmark methods. The outcomes of this study are significant in promoting the application of proximity perception in robot hand-arm systems and upper-limb prostheses.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (3) , 563-579
Toward Human-in-the-Loop Shared Control for Upper-Limb Prostheses: A Systematic Analysis of State-of-the-Art Technologies
Dexterous prosthetic hand is an essential rehabilitation assistant device to improve the life quality of amputee patients. Despite the continuous emergence of commercial prostheses and laboratory prototypes, the rejection rate remains high caused by the poor neural interaction performance and excessive cognitive burden, especially for the usage of upper-arm prostheses controlled by above-the-elbow amputation stump. The progress in artificial perception, bidirectional neural interface and share control indicates a great potential to improve the manipulation efficiency of upper-limb prostheses. In this review, a comprehensive analysis of human-in-the-loop shared control studies is presented to provide researchers with a systematic technical route in upper-limb prostheses control. The latest avenues of research concerning myoelectric control, sensory feedback, perception, autonomous motion planning of multiple degree of freedom elbow-wrist, and share control are overviewed and discussed. The comprehensive assessments show that there remains inadequate technologies to achieve an anthropomorphic and efficient unified elbow-wrist-hand prostheses manipulation. By delineating the current shortcomings, the outcomes of this work highlight future investigation in the field of intuitive motion control, feedback of proprioception/touch and the natural interaction between human intent and machine autonomy.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (3) , 563-579
Toward Human-in-the-Loop Shared Control for Upper-Limb Prostheses: A Systematic Analysis of State-of-the-Art Technologies
Dexterous prosthetic hand is an essential rehabilitation assistant device to improve the life quality of amputee patients. Despite the continuous emergence of commercial prostheses and laboratory prototypes, the rejection rate remains high caused by the poor neural interaction performance and excessive cognitive burden, especially for the usage of upper-arm prostheses controlled by above-the-elbow amputation stump. The progress in artificial perception, bidirectional neural interface and share control indicates a great potential to improve the manipulation efficiency of upper-limb prostheses. In this review, a comprehensive analysis of human-in-the-loop shared control studies is presented to provide researchers with a systematic technical route in upper-limb prostheses control. The latest avenues of research concerning myoelectric control, sensory feedback, perception, autonomous motion planning of multiple degree of freedom elbow-wrist, and share control are overviewed and discussed. The comprehensive assessments show that there remains inadequate technologies to achieve an anthropomorphic and efficient unified elbow-wrist-hand prostheses manipulation. By delineating the current shortcomings, the outcomes of this work highlight future investigation in the field of intuitive motion control, feedback of proprioception/touch and the natural interaction between human intent and machine autonomy.
- 8 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 24418-24429
A Closed-Loop Automated Craniotomy System With Real-Time Bio-Impedance Feedback
Cranial microsurgery is a prerequisite for neuroscience research, which provides an accessible brain for neural recording and optogenetic stimulation. As the scale of electrode implantation increases, massive delicate craniotomies are required to perform on the sub-millimeter-thick skull of small animals (e.g. mice). Automated craniotomy (AMC) is ideal for improving surgery efficiency and ensuring consistent results. However, the current AMC platforms are prone to over-drilling and injuring brain tissues due to the lack of effective feedback. Fragile and ultrathin skulls of these small objects also make it hard to integrate suitable sensors into the end-effector for accurate perception. Thus, this paper proposes an integrated electrical bioimpedance measurement (EBIM) solution for the closed-loop AMC. A sensing drill and a custom EBIM device are implemented to form a reliable electrical contact with the object and accurately measure the impedance. After evaluating the integrated EBIM device’s accuracy(<2% relative error) and stability, we provide a modified judgment signal for breakthrough detection and further simulate closed-loop craniotomies on an equivalent model. The experimental results demonstrate that the proposed system can achieve sensitive breakthrough detection (<0.1s delay at 100Hz excitation) and consistent drilling depth (10.3μm deviation with 10mm/min feed rate) in contrast to the gold standard (LCR meter).
- 8 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 24418-24429
A Closed-Loop Automated Craniotomy System With Real-Time Bio-Impedance Feedback
Cranial microsurgery is a prerequisite for neuroscience research, which provides an accessible brain for neural recording and optogenetic stimulation. As the scale of electrode implantation increases, massive delicate craniotomies are required to perform on the sub-millimeter-thick skull of small animals (e.g. mice). Automated craniotomy (AMC) is ideal for improving surgery efficiency and ensuring consistent results. However, the current AMC platforms are prone to over-drilling and injuring brain tissues due to the lack of effective feedback. Fragile and ultrathin skulls of these small objects also make it hard to integrate suitable sensors into the end-effector for accurate perception. Thus, this paper proposes an integrated electrical bioimpedance measurement (EBIM) solution for the closed-loop AMC. A sensing drill and a custom EBIM device are implemented to form a reliable electrical contact with the object and accurately measure the impedance. After evaluating the integrated EBIM device’s accuracy(<2% relative error) and stability, we provide a modified judgment signal for breakthrough detection and further simulate closed-loop craniotomies on an equivalent model. The experimental results demonstrate that the proposed system can achieve sensitive breakthrough detection (<0.1s delay at 100Hz excitation) and consistent drilling depth (10.3μm deviation with 10mm/min feed rate) in contrast to the gold standard (LCR meter).