FYFeng Yin

Feng Yin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Feng Yin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • He Sun

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China

    1 shared publication
  • Jiahao Ren

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China

    1 shared publication
  • Jian Li

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China

    1 shared publication
  • Junkai Tong

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China

    1 shared publication
  • Lin Liang

    Schlumberger-Doll Research, Cambridge, MA, USA

    1 shared publication
  • Min Lin

    Department of Mechanical Engineering, University of Wyoming, Laramie, WY, USA

    1 shared publication

Latest Publications

  • Transcranial Ultrasound Imaging With Decomposition Descent Learning-Based Full Waveform Inversion

    by Junkai Tong, Xiaocen Wang, Jiahao Ren, Min Lin, Jian Li, He Sun, Feng Yin, Lin Liang, Yang Liu

    Noninvasive brain diagnosis is extremely important because of its efficiency, low cost and painless nature to the prediction of stroke, cerebral hemorrhage and other brain researches. At present, achieving full three-dimensional quantitative ultrasonic imaging of the human brain is a cutting-edge challenge due to complex structures of the human brain and strong scattering caused by the skulls. In this article, we achieved quantitative ultrasonic imaging of inside-brain anomalies with our proposed method, the decomposition descent learning based full waveform inversion (DDL-FWI). The proposed method adopts a linear residual decomposing technique to greatly alleviate the computation burden in fast inversion tomography (FIT) with enhanced convergence guaranteed by residual functions. Testing results in both simulation and laboratory experiments demonstrated that our method can achieve high quality quantitative imaging of brain soft tissues and skulls even starting from homogeneous water background in 2D, and this method is capable of reconstructing both complex brain tissues and clots in 2D and 3D cases using either clean or noisy signals, with a robust 3D clot resolution as small as 18 mm and 2D reconstruction speed in 11.20 seconds. Combined with advanced ultrasonic hardware, DDL-FWI can be easily trained and used for brain imaging efficiently that frees patients from harmful influences from traditional imaging techniques, e.g., ionization radiations from X-ray computed tomography.