Fan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fan Zhang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fabian Buchfellner
Photonics Lab of Munich University of Applied Sciences, Munich, Germany
2 shared publications - Minghong Yang
Wuhan University of Technology
2 shared publications - Qiang Bian
College of Meteorology and Oceanography, National University of Defense Technology, Changsha 410073, China
2 shared publications - Alexander Roehrl
Photonics Lab of Munich University of Applied Sciences, Munich, Germany
1 shared publication - Alexander Wilhelm Koch
Institute for Measurement Systems and Sensor Technology, Technical University of Munich, Theresienstr. 90, 80333 Munich, Germany
1 shared publication - Andrea Stadler
Photonics Laboratory, Munich University of Applied Sciences, Munich, Germany
1 shared publication
Latest Publications
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 12974-12982
Linearized Temperature-Compensated Hydrogen Sensing With Partially Pd-Alloy-Coated π-FBGs
Intra-spectral referencing comprises a single-sensor solution, where simultaneous measurements of hydrogen concentration and temperature are achieved within a single, partially palladium-coated π-phase-shifted Fiber Bragg Grating (FBG). Highly localized, hydrogen-induced strain sections provoke the notch and the envelope of the π-FBG spectrum to yield different hydrogen responses, while temperature affects both features almost identically. The precise temperature compensation in sub-Kelvin ranges was used to characterize the functional layer in the range of 20-50°C and at 250-20,000 ppm H2 in N2. Upon initial hydrogen exposure after fabrication, a gradually decreasing sensitivity drift was observed, which relaxed and stabilized after sufficiently long initialization with hydrogen. The desorption consisted of at least two processes, a fast desorption when large amounts of hydrogen are present in the nanofilm, followed by a notably slow desorption (~5 hrs) until the baseline was recovered. A zero-point referenced calibration scheme of the PTFE-capped Pd91:Ni09 fiber optic hydrogen sensor revealed a strong non-linear response especially at low concentrations 90 = 19s for ab- and t10 = 18s for desorption. This work paves the way for both practical applications of fiber optic H2 sensors and fundamental research in Pd nanofilm engineering.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 12974-12982
Linearized Temperature-Compensated Hydrogen Sensing With Partially Pd-Alloy-Coated π-FBGs
Intra-spectral referencing comprises a single-sensor solution, where simultaneous measurements of hydrogen concentration and temperature are achieved within a single, partially palladium-coated π-phase-shifted Fiber Bragg Grating (FBG). Highly localized, hydrogen-induced strain sections provoke the notch and the envelope of the π-FBG spectrum to yield different hydrogen responses, while temperature affects both features almost identically. The precise temperature compensation in sub-Kelvin ranges was used to characterize the functional layer in the range of 20-50°C and at 250-20,000 ppm H2 in N2. Upon initial hydrogen exposure after fabrication, a gradually decreasing sensitivity drift was observed, which relaxed and stabilized after sufficiently long initialization with hydrogen. The desorption consisted of at least two processes, a fast desorption when large amounts of hydrogen are present in the nanofilm, followed by a notably slow desorption (~5 hrs) until the baseline was recovered. A zero-point referenced calibration scheme of the PTFE-capped Pd91:Ni09 fiber optic hydrogen sensor revealed a strong non-linear response especially at low concentrations 90 = 19s for ab- and t10 = 18s for desorption. This work paves the way for both practical applications of fiber optic H2 sensors and fundamental research in Pd nanofilm engineering.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 23982-23989
Performance of Fiber-Optic Hydrogen Sensor Based on Locally Coated π-Shifted FBG
Pd-based alloy coating on optical fiber is widely employed for hydrogen concentration sensing. However, it is difficult to distinguish the Pd-based alloy expansion from hydrogen-adsorption or thermal-effect. In this paper, a novel fiber-optic hydrogen sensor based on π-shifted FBG with locally coated Pd/Ta alloy layer, which enables an in-situ temperature compensation, is proposed and experimentally demonstrated. The hydrogen sensitivity difference between the extremely narrow peak of π-shifted FBG and the sidelobe wavelength are employed to realize the hydrogen concentration detection with temperature compensation. Theoretical simulation and experiment show that the hydrogen sensitivity of the structure can be enhanced by optimizing the partially-coating length. When the alloy length is 2 mm for a 10 mm-grating, the wavelength shifts of central and sidelobe 19.2 pm and 6.0 pm are achieved respectively at 1% hydrogen concentration. Maximum hydrogen sensitivity after temperature compensation of 13.2 pm is obtained. The proposed local-compensated method based on partially-coating on π-shifted FBG is particularly potential for oxygen-free environments with high requirement on hydrogen accuracy.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 23982-23989
Performance of Fiber-Optic Hydrogen Sensor Based on Locally Coated π-Shifted FBG
Pd-based alloy coating on optical fiber is widely employed for hydrogen concentration sensing. However, it is difficult to distinguish the Pd-based alloy expansion from hydrogen-adsorption or thermal-effect. In this paper, a novel fiber-optic hydrogen sensor based on π-shifted FBG with locally coated Pd/Ta alloy layer, which enables an in-situ temperature compensation, is proposed and experimentally demonstrated. The hydrogen sensitivity difference between the extremely narrow peak of π-shifted FBG and the sidelobe wavelength are employed to realize the hydrogen concentration detection with temperature compensation. Theoretical simulation and experiment show that the hydrogen sensitivity of the structure can be enhanced by optimizing the partially-coating length. When the alloy length is 2 mm for a 10 mm-grating, the wavelength shifts of central and sidelobe 19.2 pm and 6.0 pm are achieved respectively at 1% hydrogen concentration. Maximum hydrogen sensitivity after temperature compensation of 13.2 pm is obtained. The proposed local-compensated method based on partially-coating on π-shifted FBG is particularly potential for oxygen-free environments with high requirement on hydrogen accuracy.