Felix Wiesner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Felix Wiesner has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Gerhard G. Paulus
Friedrich Schiller University
5 shared publicationsJulius Reinhard
Institute of Optics and Quantum Electronics, Friedrich Schiller University Jena, Germany
5 shared publicationsMartin Wünsche
Institute of Optics and Quantum Electronics, Friedrich Schiller University Jena, Germany
5 shared publicationsSilvio Fuchs
Institute of Optics and Quantum Electronics, Friedrich Schiller University Jena, Germany
5 shared publicationsJohann J. Abel
Institute of Optics and Quantum Electronics, Friedrich Schiller University Jena, Germany
4 shared publicationsUwe Hübner
Leibniz Institute of Photonic Technology (Leibniz-IPHT) Albert-Einstein-Str. 9 07745 Jena Germany
4 shared publications
Latest Publications
- Open Access
Soft X-ray imaging with coherence tomography in the water window spectral range using high-harmonic generation
High-harmonic generation (HHG) is used as a source for various imaging applications in the extreme ultraviolet spectral range. It offers spatially coherent radiation and unique elemental contrast with the potential for attosecond time resolution. The unfavorable efficiency scaling to higher photon energies prevented the imaging application in the soft X-ray range so far. In this work we demonstrate the feasibility of using harmonics for imaging in the water window spectral region (284$\,$eV to 532$\,$eV). We achieve nondestructive depth profile imaging in a heterostructure by utilizing a broadband and noise-resistant technique called soft X-ray Coherence Tomography (SXCT) at a high-flux lab-scale HHG source. SXCT is derived from Optical Coherence Tomography, a Fourier based technique, that can use the full bandwidth of the source to reach an axial resolution of 12$\,$nm in this demonstration. The employed source covers the entire water window, with a photon flux exceeding 10$^\text{6}\,$photons/eV/s at a photon energy of 500$\,$eV. We show local cross sections of a sample consisting of Aluminium oxide and Platinum layers of varying thickness on a Zinc oxide substrate. We validate the findings with scanning and transmission electron microscopy after preparation with focused ion beam milling.
Open AccessSoft X-ray imaging with coherence tomography in the water window spectral range using high-harmonic generation
High-harmonic generation (HHG) is used as a source for various imaging applications in the extreme ultraviolet spectral range. It offers spatially coherent radiation and unique elemental contrast with the potential for attosecond time resolution. The unfavorable efficiency scaling to higher photon energies prevented the imaging application in the soft X-ray range so far. In this work we demonstrate the feasibility of using harmonics for imaging in the water window spectral region (284$\,$eV to 532$\,$eV). We achieve nondestructive depth profile imaging in a heterostructure by utilizing a broadband and noise-resistant technique called soft X-ray Coherence Tomography (SXCT) at a high-flux lab-scale HHG source. SXCT is derived from Optical Coherence Tomography, a Fourier based technique, that can use the full bandwidth of the source to reach an axial resolution of 12$\,$nm in this demonstration. The employed source covers the entire water window, with a photon flux exceeding 10$^\text{6}\,$photons/eV/s at a photon energy of 500$\,$eV. We show local cross sections of a sample consisting of Aluminium oxide and Platinum layers of varying thickness on a Zinc oxide substrate. We validate the findings with scanning and transmission electron microscopy after preparation with focused ion beam milling.
- 17 July 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (21) , 5699-5705
Wavelength-tolerant generation of Bessel-Gaussian beams using vortex phase plates
With their nearly non-diffracting and self-healing nature, Bessel-Gaussian beams (BGBs) are attractive for many applications ranging from free-space communications to nonlinear optics. BGBs can successfully be generated on background laser beams by imprinting and subsequently annihilating multiply charged optical vortices followed by focusing the resulting ring-shaped beam with a thin lens. For high-power applications optical vortices are preferentially created by spiral phase plates because of their high damage threshold. These are fabricated to realize an azimuthal change of the accumulated phase of a multiple of 2π at a predetermined wavelength. This raises the expectation that the use of spiral phase plates for the generation of BGBs is limited to the design wavelength and therefore not applicable to broadband applications involving short-pulse lasers. In this paper we present experimental data showing that this limitation can be overcome in a broad spectral range around the design wavelength. Experimental cross-sections of the BGBs for several off-design wavelengths are found in a good quantitative agreement with the theoretical Bessel functions at distances up to 540 cm after the focus of the lens.
- 17 July 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (21) , 5699-5705
Wavelength-tolerant generation of Bessel-Gaussian beams using vortex phase plates
With their nearly non-diffracting and self-healing nature, Bessel-Gaussian beams (BGBs) are attractive for many applications ranging from free-space communications to nonlinear optics. BGBs can successfully be generated on background laser beams by imprinting and subsequently annihilating multiply charged optical vortices followed by focusing the resulting ring-shaped beam with a thin lens. For high-power applications optical vortices are preferentially created by spiral phase plates because of their high damage threshold. These are fabricated to realize an azimuthal change of the accumulated phase of a multiple of 2π at a predetermined wavelength. This raises the expectation that the use of spiral phase plates for the generation of BGBs is limited to the design wavelength and therefore not applicable to broadband applications involving short-pulse lasers. In this paper we present experimental data showing that this limitation can be overcome in a broad spectral range around the design wavelength. Experimental cross-sections of the BGBs for several off-design wavelengths are found in a good quantitative agreement with the theoretical Bessel functions at distances up to 540 cm after the focus of the lens.
- 1 January 2024
- Published by Optica Publishing Group
- p. EW2A.3
Optical coherence tomography of encapsulated two-dimensional materials using extreme ultraviolet radiation from high-harmonic generation sources
We present the investigation of encapsulated two-dimensional materials with extreme ultraviolet (EUV) coherence tomography. This method is demonstrated on encapsulated graphene using EUV radiation produced by a high-harmonic generation source.
- 1 January 2024
- Published by Optica Publishing Group
- p. EW2A.3
Optical coherence tomography of encapsulated two-dimensional materials using extreme ultraviolet radiation from high-harmonic generation sources
We present the investigation of encapsulated two-dimensional materials with extreme ultraviolet (EUV) coherence tomography. This method is demonstrated on encapsulated graphene using EUV radiation produced by a high-harmonic generation source.
- Open Access
- 7 November 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (6) , 2014-2025
Laboratory-Based Correlative Soft X-ray and Fluorescence Microscopy in an Integrated Setup
Correlative microscopy is a powerful technique that combines the advantages of multiple imaging modalities to achieve a comprehensive understanding of investigated samples. For example, fluorescence microscopy provides unique functional contrast by imaging only specifically labeled components, especially in biological samples. However, the achievable structural information on the sample in its full complexity is limited. Here, the intrinsic label-free carbon contrast of water window soft X-ray microscopy can complement fluorescence images in a correlative approach ultimately combining nanoscale structural resolution with functional contrast. However, soft X-ray microscopes are complex and elaborate, and are usually installed on large-scale synchrotron radiation sources due to the demanding photon flux requirements. Yet, with modern high-power lasers it has become possible to generate sufficient photon flux from laser-produced plasmas, thus enabling laboratory-based setups. Here, we present a compact table-top soft X-ray microscope with an integrated epifluorescence modality for “in situ” correlative imaging. Samples remain in place when switching between modalities, ensuring identical measurement conditions and avoiding sample alteration or destruction. We demonstrate our new method by multimodal images of several exemplary samples ranging from nanoparticles to various multicolor labeled cell types. A structural resolution of down to 50 nm was reached.
- 7 November 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (6) , 2014-2025
Open AccessLaboratory-Based Correlative Soft X-ray and Fluorescence Microscopy in an Integrated Setup
Correlative microscopy is a powerful technique that combines the advantages of multiple imaging modalities to achieve a comprehensive understanding of investigated samples. For example, fluorescence microscopy provides unique functional contrast by imaging only specifically labeled components, especially in biological samples. However, the achievable structural information on the sample in its full complexity is limited. Here, the intrinsic label-free carbon contrast of water window soft X-ray microscopy can complement fluorescence images in a correlative approach ultimately combining nanoscale structural resolution with functional contrast. However, soft X-ray microscopes are complex and elaborate, and are usually installed on large-scale synchrotron radiation sources due to the demanding photon flux requirements. Yet, with modern high-power lasers it has become possible to generate sufficient photon flux from laser-produced plasmas, thus enabling laboratory-based setups. Here, we present a compact table-top soft X-ray microscope with an integrated epifluorescence modality for “in situ” correlative imaging. Samples remain in place when switching between modalities, ensuring identical measurement conditions and avoiding sample alteration or destruction. We demonstrate our new method by multimodal images of several exemplary samples ranging from nanoparticles to various multicolor labeled cell types. A structural resolution of down to 50 nm was reached.
- Open Access
- 15 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 47867-47878
Broadband soft X-ray source from a clustered gas target dedicated to high-resolution XCT and X-ray absorption spectroscopy
The development of the broad-bandwidth photon sources emitting in the soft X-ray range has attracted great attention for a long time due to the possible applications in high-resolution spectroscopy, nano-metrology, and material sciences. A high photon flux accompanied by a broad, smooth spectrum is favored for the applications such as near-edge X-ray absorption fine structure (NEXAFS), extended X-ray absorption fine structure (EXAFS), or XUV/X-ray coherence tomography (XCT). So far, either large-scale facilities or technologically challenging systems providing only limited photon flux in a single shot dominate the suitable sources. Here, we present a soft, broad-band (1.5 nm - 10.7 nm) soft X-ray source. The source is based on the interaction of very intense laser pulses with a target formed by a cluster mixture. A photon yield of 2.4 × 1014 photons/pulse into 4π (full space) was achieved with a medium containing Xe clusters of moderate-size mixed with a substantial amount of extremely large ones. It is shown that such a cluster mixture enhances the photon yield in the soft X-ray range by roughly one order of magnitude. The size of the resulting source is not beneficial (≤500 µm but this deficit is compensated by a specific spectral structure of its emission fulfilling the specific needs of the spectroscopic (broad spectrum and high signal dynamics) and metrological applications (broad and smoothed spectrum enabling a sub-nanometer resolution limit for XCT).
- 15 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 47867-47878
Open AccessBroadband soft X-ray source from a clustered gas target dedicated to high-resolution XCT and X-ray absorption spectroscopy
The development of the broad-bandwidth photon sources emitting in the soft X-ray range has attracted great attention for a long time due to the possible applications in high-resolution spectroscopy, nano-metrology, and material sciences. A high photon flux accompanied by a broad, smooth spectrum is favored for the applications such as near-edge X-ray absorption fine structure (NEXAFS), extended X-ray absorption fine structure (EXAFS), or XUV/X-ray coherence tomography (XCT). So far, either large-scale facilities or technologically challenging systems providing only limited photon flux in a single shot dominate the suitable sources. Here, we present a soft, broad-band (1.5 nm - 10.7 nm) soft X-ray source. The source is based on the interaction of very intense laser pulses with a target formed by a cluster mixture. A photon yield of 2.4 × 1014 photons/pulse into 4π (full space) was achieved with a medium containing Xe clusters of moderate-size mixed with a substantial amount of extremely large ones. It is shown that such a cluster mixture enhances the photon yield in the soft X-ray range by roughly one order of magnitude. The size of the resulting source is not beneficial (≤500 µm but this deficit is compensated by a specific spectral structure of its emission fulfilling the specific needs of the spectroscopic (broad spectrum and high signal dynamics) and metrological applications (broad and smoothed spectrum enabling a sub-nanometer resolution limit for XCT).
- Open Access
- 15 September 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (20) , 35671
Absolute EUV reflectivity measurements using a broadband high-harmonic source and an in situ single exposure reference scheme
We present a tabletop setup for extreme ultraviolet (EUV) reflection spectroscopy in the spectral range from 40 to 100 eV by using high-harmonic radiation. The simultaneous measurements of reference and sample spectra with high energy resolution provide precise and robust absolute reflectivity measurements, even when operating with spectrally fluctuating EUV sources. The stability and sensitivity of EUV reflectivity measurements are crucial factors for many applications in attosecond science, EUV spectroscopy, and nano-scale tomography. We show that the accuracy and stability of our in situ referencing scheme are almost one order of magnitude better in comparison to subsequent reference measurements. We demonstrate the performance of the setup by reflective near-edge x-ray absorption fine structure measurements of the aluminum L2/3 absorption edge in α-Al2O3 and compare the results to synchrotron measurements.
- 15 September 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (20) , 35671
Open AccessAbsolute EUV reflectivity measurements using a broadband high-harmonic source and an in situ single exposure reference scheme
We present a tabletop setup for extreme ultraviolet (EUV) reflection spectroscopy in the spectral range from 40 to 100 eV by using high-harmonic radiation. The simultaneous measurements of reference and sample spectra with high energy resolution provide precise and robust absolute reflectivity measurements, even when operating with spectrally fluctuating EUV sources. The stability and sensitivity of EUV reflectivity measurements are crucial factors for many applications in attosecond science, EUV spectroscopy, and nano-scale tomography. We show that the accuracy and stability of our in situ referencing scheme are almost one order of magnitude better in comparison to subsequent reference measurements. We demonstrate the performance of the setup by reflective near-edge x-ray absorption fine structure measurements of the aluminum L2/3 absorption edge in α-Al2O3 and compare the results to synchrotron measurements.
- Open Access
- 18 August 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (18) , 32267-32279
Characterization of encapsulated graphene layers using extreme ultraviolet coherence tomography
Many applications of two-dimensional materials such as graphene require the encapsulation in bulk material. While a variety of methods exist for the structural and functional characterization of uncovered 2D materials, there is a need for methods that image encapsulated 2D materials as well as the surrounding matter. In this work, we use extreme ultraviolet coherence tomography to image graphene flakes buried beneath 200 nm of silicon. We show that we can identify mono-, bi-, and trilayers of graphene and quantify the thickness of the silicon bulk on top by measuring the depth-resolved reflectivity. Furthermore, we estimate the quality of the graphene interface by incorporating a model that includes the interface roughness. These results are verified by atomic force microscopy and prove that extreme ultraviolet coherence tomography is a suitable tool for imaging 2D materials embedded in bulk materials.
- 18 August 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (18) , 32267-32279
Open AccessCharacterization of encapsulated graphene layers using extreme ultraviolet coherence tomography
Many applications of two-dimensional materials such as graphene require the encapsulation in bulk material. While a variety of methods exist for the structural and functional characterization of uncovered 2D materials, there is a need for methods that image encapsulated 2D materials as well as the surrounding matter. In this work, we use extreme ultraviolet coherence tomography to image graphene flakes buried beneath 200 nm of silicon. We show that we can identify mono-, bi-, and trilayers of graphene and quantify the thickness of the silicon bulk on top by measuring the depth-resolved reflectivity. Furthermore, we estimate the quality of the graphene interface by incorporating a model that includes the interface roughness. These results are verified by atomic force microscopy and prove that extreme ultraviolet coherence tomography is a suitable tool for imaging 2D materials embedded in bulk materials.
- 1 January 2019
- Published by Optica Publishing Group
- p. W4B.5
Label-free quantitative material sensitive tomography with extreme ultraviolet light
We report on quantitative material-sensitive cross-sectional imaging with nanoscale axial resolution. First experimental results show that in addition to the structural information element-specific identification of buried layers is possible.
- 1 January 2019
- Published by Optica Publishing Group
- p. W4B.5
Label-free quantitative material sensitive tomography with extreme ultraviolet light
We report on quantitative material-sensitive cross-sectional imaging with nanoscale axial resolution. First experimental results show that in addition to the structural information element-specific identification of buried layers is possible.