Amrest Chinkamol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amrest Chinkamol has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Theerawit Wilaiprasitporn
Vidyasirimedhi Institute of Science and Technology (VISTEC)
3 shared publications - Kamonwan Thanontip
Bio-Inspired Robotics and Neural Engineering (BRAIN) Laboratory, School of Information Science and Technology (IST), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand
2 shared publications - Thapanun Sudhawiyangkul
Bio-inspired Robotics and Neural Engineering (BRAIN) Lab, School of Information Science and Technology (IST), Vidyasirimedhi Institute of Science & Technology (VISTEC), Rayong, Thailand
2 shared publications - Chantana Chantrapornchai
Department of Computer Engineering, Faculty of Engineering, Kasetsart University, Bangkok 10900, Thailand
1 shared publication - Chiraphat Boonnag
Biomedical Informatics Center, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
1 shared publication Chnan Likitvanichkul
Department of Computer Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
1 shared publication
Latest Publications
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (15) , 13196-13204
PACMAN: A Framework for Pulse Oximeter Digit Detection and Reading in a Low-Resource Setting
In light of the COVID-19 pandemic, patients were required to manually input their daily oxygen saturation (SpO2) and pulse rate (PR) values into a health monitoring system—unfortunately, such a process trend to be an error in typing. Several studies attempted to detect the physiological value from the captured image using optical character recognition (OCR). However, the technology has limited availability with high cost. Thus, this study aimed to propose a novel framework called PACMAN (Pandemic Accelerated Human-Machine Collaboration) with a low-resource deep learning-based computer vision. We compared state-of-the-art object detection algorithms (scaled YOLOv4, YOLOv5, and YOLOR), including the commercial OCR tools for digit recognition on the captured images from the pulse oximeter display. All images were derived from crowdsourced data collection with varying quality and alignment. YOLOv5 was the best-performing model against the given model comparison across all datasets, notably the correctly orientated image dataset. We further improved the model performance with the digits auto-orientation algorithm and applied a clustering algorithm to extract SpO2 and PR values. The accuracy performance of YOLOv5 with the implementations was approximately 81.0-89.5%, which was enhanced compared to without any additional implementation. Accordingly, this study highlighted the completion of the PACMAN framework to detect and read digits in real-world datasets. The proposed framework has been currently integrated into the patient monitoring system utilized by hospitals nationwide.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (15) , 13196-13204
PACMAN: A Framework for Pulse Oximeter Digit Detection and Reading in a Low-Resource Setting
In light of the COVID-19 pandemic, patients were required to manually input their daily oxygen saturation (SpO2) and pulse rate (PR) values into a health monitoring system—unfortunately, such a process trend to be an error in typing. Several studies attempted to detect the physiological value from the captured image using optical character recognition (OCR). However, the technology has limited availability with high cost. Thus, this study aimed to propose a novel framework called PACMAN (Pandemic Accelerated Human-Machine Collaboration) with a low-resource deep learning-based computer vision. We compared state-of-the-art object detection algorithms (scaled YOLOv4, YOLOv5, and YOLOR), including the commercial OCR tools for digit recognition on the captured images from the pulse oximeter display. All images were derived from crowdsourced data collection with varying quality and alignment. YOLOv5 was the best-performing model against the given model comparison across all datasets, notably the correctly orientated image dataset. We further improved the model performance with the digits auto-orientation algorithm and applied a clustering algorithm to extract SpO2 and PR values. The accuracy performance of YOLOv5 with the implementations was approximately 81.0-89.5%, which was enhanced compared to without any additional implementation. Accordingly, this study highlighted the completion of the PACMAN framework to detect and read digits in real-world datasets. The proposed framework has been currently integrated into the patient monitoring system utilized by hospitals nationwide.
- 26 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1931-1942
OCTAve: 2D En Face Optical Coherence Tomography Angiography Vessel Segmentation in Weakly-Supervised Learning With Locality Augmentation
Objective: While the microvasculature annotation within Optical Coherence Tomography Angiography (OCTA) can be leveraged using deep-learning techniques, expensive annotation processes are required to create sufficient training data. One way to avoid the expensive annotation is to use a type of weak annotation in which only the center of the vessel is annotated. However, retaining the final segmentation quality with roughly annotated data remains a challenge. Methods: Our proposed methods, called OCTAve, provide a new way of using weak-annotation for microvasculature segmentation. Since the centerline labels are similar to scribble annotations, we attempted to solve this problem by using the scribble-based weakly-supervised learning method. Even though the initial results look promising, we found that the method could be significantly improved by adding our novel self-supervised deep supervision method based on Kullback-Liebler divergence. Results: The study on large public datasets with different annotation styles (i.e., ROSE, OCTA-500) demonstrates that our proposed method gives better quantitative and qualitative results than the baseline methods and a naive approach, with a p-value less than 0.001 on dice's coefficient and a lot fewer artifacts. Conclusion: The segmentation results are both qualitatively and quantitatively superior to baseline weakly-supervised methods when using scribble-based weakly-supervised learning augmented with self-supervised deep supervision, with an average drop in segmentation performance of less than 10%. Significance: This work gives a new perspective on how weakly-supervised learning can be used to reduce the cost of annotating microvasculature, which can make the annotating process easier and reduce the amount of work for domain experts.
- 26 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1931-1942
OCTAve: 2D En Face Optical Coherence Tomography Angiography Vessel Segmentation in Weakly-Supervised Learning With Locality Augmentation
Objective: While the microvasculature annotation within Optical Coherence Tomography Angiography (OCTA) can be leveraged using deep-learning techniques, expensive annotation processes are required to create sufficient training data. One way to avoid the expensive annotation is to use a type of weak annotation in which only the center of the vessel is annotated. However, retaining the final segmentation quality with roughly annotated data remains a challenge. Methods: Our proposed methods, called OCTAve, provide a new way of using weak-annotation for microvasculature segmentation. Since the centerline labels are similar to scribble annotations, we attempted to solve this problem by using the scribble-based weakly-supervised learning method. Even though the initial results look promising, we found that the method could be significantly improved by adding our novel self-supervised deep supervision method based on Kullback-Liebler divergence. Results: The study on large public datasets with different annotation styles (i.e., ROSE, OCTA-500) demonstrates that our proposed method gives better quantitative and qualitative results than the baseline methods and a naive approach, with a p-value less than 0.001 on dice's coefficient and a lot fewer artifacts. Conclusion: The segmentation results are both qualitatively and quantitatively superior to baseline weakly-supervised methods when using scribble-based weakly-supervised learning augmented with self-supervised deep supervision, with an average drop in segmentation performance of less than 10%. Significance: This work gives a new perspective on how weakly-supervised learning can be used to reduce the cost of annotating microvasculature, which can make the annotating process easier and reduce the amount of work for domain experts.
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 24550-24558
Prescreening MCI and Dementia Using Shank-Mounted IMU During TUG Task
Detection of mild cognitive impairment (MCI) and dementia (DEM) is an important topic because, unless it is treated early, MCI can progress to DEM, which is an untreatable disease. This paper proposes a timed-up-and-go (TUG) task features analysis and classification of MCI and DEM using inertial measurement units (IMU) in wearable devices. Our goal is to create a generalized model that can be used for pre-clinical screening. As a result, rather than classifying only one subtype of dementia, such as Alzheimer’s disease (AD) or Parkinson’s disease (PD), we classify all subtypes as DEM. We also utilize feature selection methods on features from TUG tasks to optimize the MCI and DEM classification performance. From the results, our generalized model can outperform other works in NC-MCI&DEM classification with accuracy of 86.94% and sensitivity of 97.40%. For NC-DEM classification, the performance of our generalized model is slightly lower than that of specific-subtype models (e.g., NC vs. AD). However, our generalized model can outperform the specific-subtype models when using with a diverse variety of subtypes. It is a reasonable trade-off, and it can be a good first step toward a future where the patient can pre-clinically self-screening the cognitive impairments using wearable devices in free-living environments. This could allow patients to notice the cognitive impairment early on and seek a comprehensive diagnosis from a doctor.
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 24550-24558
Prescreening MCI and Dementia Using Shank-Mounted IMU During TUG Task
Detection of mild cognitive impairment (MCI) and dementia (DEM) is an important topic because, unless it is treated early, MCI can progress to DEM, which is an untreatable disease. This paper proposes a timed-up-and-go (TUG) task features analysis and classification of MCI and DEM using inertial measurement units (IMU) in wearable devices. Our goal is to create a generalized model that can be used for pre-clinical screening. As a result, rather than classifying only one subtype of dementia, such as Alzheimer’s disease (AD) or Parkinson’s disease (PD), we classify all subtypes as DEM. We also utilize feature selection methods on features from TUG tasks to optimize the MCI and DEM classification performance. From the results, our generalized model can outperform other works in NC-MCI&DEM classification with accuracy of 86.94% and sensitivity of 97.40%. For NC-DEM classification, the performance of our generalized model is slightly lower than that of specific-subtype models (e.g., NC vs. AD). However, our generalized model can outperform the specific-subtype models when using with a diverse variety of subtypes. It is a reasonable trade-off, and it can be a good first step toward a future where the patient can pre-clinically self-screening the cognitive impairments using wearable devices in free-living environments. This could allow patients to notice the cognitive impairment early on and seek a comprehensive diagnosis from a doctor.