Yeonhee Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yeonhee Chang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Cheol Song
Department of Robotics and Mechatronics Engineering, DGIST, Daegu, South Korea
4 shared publications - Jintaek Im
Department of Robotics and Mechatronics Engineering, DGIST, Daegu, South Korea
3 shared publications - Myung Ho Lee
Department of Robotics and Mechatronics Engineering, DGIST, Daegu, Republic of Korea
2 shared publications - Chaebeom Yeo
Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu 42988, Republic of Korea
1 shared publication Daegab Gweon
Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea
1 shared publication- Dukho Do
Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea
1 shared publication
Latest Publications
- 11 February 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 401
Lissajous multi-modal endomicroscopy with optical coherence tomography and confocal fluorescence microscopy
- 11 February 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 401
Lissajous multi-modal endomicroscopy with optical coherence tomography and confocal fluorescence microscopy
- Open Access
- 25 October 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (4) , 045024
Machine-learning-based diabetes classification method using blood flow oscillations and Pearson correlation analysis of feature importance
Diabetes is a global health issue affecting millions of people and is related to high morbidity and mortality rates. Current diagnostic methods are primarily invasive, involving blood sampling, which can lead to infection and increased patient stress. As a result, there is a growing need for noninvasive diabetes diagnostic methods that are both accurate and fast. High measurement accuracy and fast measurement time are essential for effective noninvasive diabetes diagnosis; these can be achieved using diffuse speckle contrast analysis (DSCA) systems and artificial intelligence algorithms. In this study, we use a machine learning algorithm to analyze rat blood flow signals measured using a DSCA system with simple operation, easy fabrication, and fast measurement for helping diagnose diabetes. The results confirmed that the machine learning algorithm for analyzing blood flow oscillation data shows good potential for diabetes classification. Furthermore, analyzing the blood flow reactivity test revealed that blood flow signals can be quickly measured for diabetes classification. Finally, we evaluated the influence of each blood flow oscillation data on diabetes classification through feature importance and Pearson correlation analysis. The results of this study should provide a basis for the future development of hemodynamic-based disease diagnostic methods.
- 25 October 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (4) , 045024
Open AccessMachine-learning-based diabetes classification method using blood flow oscillations and Pearson correlation analysis of feature importance
Diabetes is a global health issue affecting millions of people and is related to high morbidity and mortality rates. Current diagnostic methods are primarily invasive, involving blood sampling, which can lead to infection and increased patient stress. As a result, there is a growing need for noninvasive diabetes diagnostic methods that are both accurate and fast. High measurement accuracy and fast measurement time are essential for effective noninvasive diabetes diagnosis; these can be achieved using diffuse speckle contrast analysis (DSCA) systems and artificial intelligence algorithms. In this study, we use a machine learning algorithm to analyze rat blood flow signals measured using a DSCA system with simple operation, easy fabrication, and fast measurement for helping diagnose diabetes. The results confirmed that the machine learning algorithm for analyzing blood flow oscillation data shows good potential for diabetes classification. Furthermore, analyzing the blood flow reactivity test revealed that blood flow signals can be quickly measured for diabetes classification. Finally, we evaluated the influence of each blood flow oscillation data on diabetes classification through feature importance and Pearson correlation analysis. The results of this study should provide a basis for the future development of hemodynamic-based disease diagnostic methods.
- Open Access
- 26 July 2023
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 17 (1)
Lissajous confocal fluorescent endomicroscopy with a lever mechanism and a frequency separation by an asymmetric polymer tube
- 26 July 2023
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 17 (1)
Open AccessLissajous confocal fluorescent endomicroscopy with a lever mechanism and a frequency separation by an asymmetric polymer tube
- Open Access
- 27 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 4829-4839
Modified Phase-Offset-Driven Lissajous Scanning Endomicroscopy With a Polyimide-Film-Based Frequency Separator
This article presents a Lissajous scanning confocal endomicroscopy comprising an easily manufacturable thin polyimide (PI) film and modified phase-offset-driven scanning. The Lissajous scanning confocal probe has a piezoelectric tube actuator and the PI film-attached fiber cantilever designed to resonate with the lever mechanism. Data from a finite element analysis and experiments are used to optimize the dimensions of the PI film, which produces a frequency separation and field of view of $195\;{\bf{Hz}}$ and $180\;\mu {\bf{m}}\; \times \;180\;\mu {\bf{m}}$ , respectively, at driving voltages less than $30\;{{\bf{V}}_{pp}}$ . The best combination of decimal frequencies with optimized driving phase offsets is determined to achieve a scanning density (SD) exceeding $80\% $ consistently with an imaging speed of $8\;{\bf{Hz}}$ . By analyzing the Lissajous patterns at different decimal frequency combinations via time-delay analysis, it is possible to find more diverse combinations that meet the SD criterion. When the scanning patterns deviate from the desired paths, the proposed modified phase-offset-driven method is applied to maintain the best scanning pattern. The USAF 1951 test pattern, several plants, and rat gastrointestinal tract were imaged successfully using the confocal endomicroscopic system with the PI film and modified phase-offset-driven scanning.- 27 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 4829-4839
Open AccessModified Phase-Offset-Driven Lissajous Scanning Endomicroscopy With a Polyimide-Film-Based Frequency Separator
This article presents a Lissajous scanning confocal endomicroscopy comprising an easily manufacturable thin polyimide (PI) film and modified phase-offset-driven scanning. The Lissajous scanning confocal probe has a piezoelectric tube actuator and the PI film-attached fiber cantilever designed to resonate with the lever mechanism. Data from a finite element analysis and experiments are used to optimize the dimensions of the PI film, which produces a frequency separation and field of view of $195\;{\bf{Hz}}$ and $180\;\mu {\bf{m}}\; \times \;180\;\mu {\bf{m}}$ , respectively, at driving voltages less than $30\;{{\bf{V}}_{pp}}$ . The best combination of decimal frequencies with optimized driving phase offsets is determined to achieve a scanning density (SD) exceeding $80\% $ consistently with an imaging speed of $8\;{\bf{Hz}}$ . By analyzing the Lissajous patterns at different decimal frequency combinations via time-delay analysis, it is possible to find more diverse combinations that meet the SD criterion. When the scanning patterns deviate from the desired paths, the proposed modified phase-offset-driven method is applied to maintain the best scanning pattern. The USAF 1951 test pattern, several plants, and rat gastrointestinal tract were imaged successfully using the confocal endomicroscopic system with the PI film and modified phase-offset-driven scanning.