OROlga Reynbakh

Olga Reynbakh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Olga Reynbakh has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ablation of atrial fibrillation beyond pulmonary vein isolation: Do additional ablation lesions impact left atrial function?

    by Olga Reynbakh, Mario Garcia, Jorge Romero, Hardikkumar Patel, Eric D. Braunstein, Melissa Fazzari, Luigi Di Biase

    Introduction: Electrical isolation of pulmonary veins (PVI) is a cornerstone for atrial fibrillation (AF) ablation. The overall effect of AF ablation, and especially lesions beyond PVI, on left atrial (LA) function is currently poorly understood. Our aim was to determine if LA function is different in patients after extensive LA ablation compared to PVI only. We performed non‐inferiority analysis of LA function after PVI with additional nonpulmonary vein ablation lesions in LA (PVI+) and PVI alone.Methods: We studied 68 patients consecutive patients who underwent AF ablation and who had complete transthoracic echocardiogram (TTE) within 12 months before AF ablation and 1−12 months after the procedure. Patients were stratified into two groups: PVI only and PVI+. Primary outcome was change in LA reservoir strain (LASr). Noninferiority margin was defined at 6%.Results: The PVI only group had a higher proportion of patients with paroxysmal AF (70% vs. 30%). The PVI+ group was observed to have a slightly higher increase in LASr compared to PVI alone (5.0% vs. 4.3%, p < .01 for noninferiority). LASr noninferiority was confirmed when adjusted for age, sex, coronary artery disease, hyperlipidemia, and AF type, rhythm at preprocedure TTE in a multivariable linear regression model, 90% CI (−5.46 to 2.04), p < .01.Conclusion: LA functional improvement evaluated by LASr was noninferior after PVI with additional LA ablation lesions compared to PVI alone. These findings were confirmed when adjusted for confounding clinical variables, suggesting that more extensive ablation does not negatively affect LA function.


  • Open Access

    Arrhythmia patterns in patients with COVID-19 infection during and post hospitalization detected via a patch-based mobile cardiac telemetry system

    by O Reynbakh, E D Braunstein, M Hsu, J Ellis, L Crosson, J Lenane, A Krumerman, L Di Biase, K J Ferrick

    Background: Coronavirus infection (COVID-19) is the cause of the current world-wide pandemic. Cardiovascular complications occur in 20–30% of patients with COVID-19 infection including myocardial injury and arrhythmias. Current understanding of specific arrhythmia type and frequency is limited. In response to COVID-19 pandemic and overwhelmed hospital critical care and telemetry recourses, patch-based cardiac monitoring system received emergency Food and Drug Administration (FDA) approval for inpatient monitoring. A patch-based cardiac telemetry system has been shown to be useful for patient management during the COVID-19 pandemic and provides detailed analysis of cardiac rhythms. Purpose: To analyze arrhythmia type and frequency in patients with COVID-19 infection, identifying arrhythmia patterns over time during hospitalization and after discharge. Methods: A prospective cohort study during the COVID-19 pandemic was performed. We included patients hospitalized with COVID-19 infection who had a patch-based mobile telemetry device placed for cardiac monitoring. A quantitative analysis including type, frequency and duration of detected arrhythmias was performed at the end of the monitoring period. Results: A total of 103 patients hospitalized with COVID-19 diagnosis underwent monitoring. Quantitative reports for 59 patients were available for analysis, among those 59% were males, median age 65 (IQR 56–76) yrs. Mean wear time was 6.8±5.0 days. Arrhythmias were detected in 72.9% of patients. Majority of arrhythmias were SVT (59.3% of patients) and AF (22.0%). Episodes of AF duration >30 min were detected in 12 patients. New onset AF was noted in 15.0% of patients and was significantly associated with age (OR 1.4 for 5 yrs difference; 95% CI 1.01–2.05). Brady arrhythmias (2nd degree, 3rd degree AV bock, pause≥3 seconds) were seen in 18.7% of patients. Arrhythmias were consistently detected throughout the monitoring period in 52.9%-89.5% of patients daily (Figure 1). In 9 patients who were discharged with continued patch monitoring, 3 patients (33.3%) had arrhythmic events during their outpatient monitoring period. Conclusion: A majority of patients hospitalized with COVID-19 infection had arrhythmias detected by patch cardiac monitor. Arrhythmias were observed throughout hospitalization with a consistent daily frequency. Patients continued to exhibit cardiac arrhythmias after hospital discharge of a type similar to that seen during hospitalization. New onset AF often occurred and was associated with older age. Inpatient application of a patch cardiac telemetry with continued monitoring as outpatient is feasible and effective in detecting occult arrhythmias in patients with COVID-19 infection. Funding Acknowledgement: Type of funding sources: None. Daily frequency of arrhythmias detected