LCLuis Chavez

Luis Chavez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luis Chavez has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Xavier Intes

    Rensselaer Polytechnic Institute, Center for Modeling, Simulation and Imaging in Medicine, Troy, New York, United States

    4 shared publications
  • Saif Ragab

    Center for Modeling, Simulation and Imaging for Medicine Rensselaer Polytechnic Institute, Troy, New York 12180, USA

    3 shared publications
  • Shan Gao

    Rensselaer Polytechnic Institute

    3 shared publications
  • Brendan F. Kennedy

    Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia

    2 shared publications
  • Caroline Edelheit

    Center for Modeling, Simulation and Imaging for Medicine, Rensselaer Polytechnic Institute, Troy, New York 12180, USA

    2 shared publications
  • David T. Corr

    Center for Modeling, Simulation and Imaging for Medicine, Rensselaer Polytechnic Institute, Troy, New York 12180, USA

    2 shared publications

Latest Publications

  • NIR-SWIR Light-Sheet Mesoscopy for 3D Drug Biodistribution and Target Engagement Mapping

    by Luis Chavez, Ismail Erbas, Isaiah Crosbourne, Saif Ragab, Vikas Pandey, Claudio Bruschini, Edoardo Charbon, Margarida Barroso, Xavier Intes

    We report on the application of a NIR-SWIR light-sheet mesoscope for 3D mapping of drug biodistribution and fluorescence lifetime in mesoscale breast cancer tumor models. Our results demonstrate our system’s potential for enabling quantitative drug delivery assessments at the whole tumor level.

  • Evaluating tartrazine as an optical clearing agent for fluorescence lifetime imaging

    by Nanxue Yuan, Saif Ragab, Luis Chavez, Vikas Pandey, Xavier Intes

    Fluorescence lifetime imaging (FLI) offers valuable insights into the molecular and functional properties of biological tissues. However, in deeper tissues, optical properties (scattering and absorption) diminish fluorescence signal significantly and complicate data interpretation. This study explores the potential of tartrazine (FD&C Yellow 5), a biocompatible and FDA-approved food dye, as an optical clearing agent for deep tissue imaging. Despite its own near-infrared (NIR) fluorescence, tartrazine’s ultrashort intrinsic lifetime (∼0.10 ns) allows for effective separation from the longer lifetimes of conventional NIR probes (>0.50 ns) using lifetime-based unmixing. We found that at an optimal concentration (≤ 0.6 M), tartrazine brings down the reduced scattering coefficient ( μ s ′ ) by more than 90%, significantly improving fluorescence signal recovery from deeper tissue regions. Our validation with multi-depth tissue phantoms showed that this method can accurately recover fluorescence signals and lifetimes from targets located more than 1 cm deep, achieving results comparable to low-scattering controls. These findings show that tartrazine is a practical and effective optical clearing agent that can enhance the depth, resolution, and quantitative accuracy of FLI in highly scattering media, such as those used in preclinical imaging studies.


  • Design and characterization of an optical phantom for mesoscopic multimodal fluorescence lifetime imaging and optical coherence elastography

    by Luis Chavez, Shan Gao, Vikas Pandey, Nanxue Yuan, Saif Ragab, Jiayue Li, Matt S. Hepburn, Percy Smith, Caroline Edelheit, David T. Corr, et al.

    We developed a novel methodology for manufacturing multimodal, tissue-mimicking phantoms that exhibit both molecular and biomechanical contrast. This methodology leverages the immiscibility of silicone and hydrogels to create solid mesoscale phantoms with localized regions of precisely controlled fluorescence, including fluorescence lifetime properties, and adjustable stiffness, without requiring physical barriers. Mechanical, fluorescent, and optical characterization confirmed the tunability of the phantoms across a range of values relevant to biomedical applications. A macroscale 3D phantom was fabricated, and its properties were validated through fluorescence lifetime imaging (FLI) and optical coherence elastography (OCE). Validation demonstrated the successful tuning of both mechanical and fluorescence lifetime contrasts within a 3D structure, highlighting the feasibility of multimodal FLI-OCE. This new phantom manufacturing process is expected to support the development and validation of new multimodal imaging approaches to study molecular and biomechanical properties of the tumor microenvironment (TME), as well as their impact on therapeutic efficacy, and to enhance targeted therapies.


  • Multimodal Fluorescence Lifetime Imaging and Optical Coherence Elastography for Mesoscopic Structural, Biomechanical, and Molecular Imaging

    by Luis Chavez, Shan Gao, Vikas Pandey, Nanxue Yuan, Jiayue Li, Matt S. Hepburn, Percy Smith, Caroline Edelheit, David T. Corr, Brendan F. Kennedy, et al.

    We report on a methodology to manufacture multimodal phantoms with fluorescence lifetime imaging and optical coherence elastography contrasts. Phantom validation demonstrates the ability to tune fluorescence and strain properties in 3D using biologically relevant matrices.


  • Open Access

    Characterization of fluorescence lifetime of organic fluorophores for molecular imaging in the shortwave infrared window

    by Luis Chavez, Shan Gao, Xavier Intes

    SignificanceFluorescence lifetime imaging in the shortwave infrared (SWIR) is expected to enable high-resolution multiplexed molecular imaging in highly scattering tissue.AimTo characterize the brightness and fluorescence lifetime of commercially available organic SWIR fluorophores and benchmark them against the tail emission of conventional NIR-excited probes.ApproachCharacterization was performed through our established time-domain mesoscopic fluorescence molecular tomography system integrated around a time-correlated single-photon counting-single-photon avalanche diode array. Brightness and fluorescence lifetime were measured for NIR and SWIR probes >1000 nm. Simultaneous probe imaging was then performed to assess their potential for multiplexed studies.ResultsThe NIR probes outperformed SWIR probes in brightness while the mean fluorescence lifetimes of the SWIR probes were extremely short. The phantom study demonstrated the feasibility of lifetime multiplexing in the SWIR window with both NIR and SWIR probes.ConclusionsLong-tail emission of NIR probes outperformed the SWIR probes in brightness >1000 nm. Fluorescence lifetime was readily detectable in the SWIR window, where the SWIR probes showed shorter lifetimes compared to the NIR probes. We demonstrate the feasibility of lifetime multiplexing in the SWIR window, which paves the way for in vivo multiplexed studies of intact tissues at improved resolution.


  • Open Access

    Characterization of fluorescence lifetime of organic fluorophores for molecular imaging in the SWIR window

    by Luis Chavez, Shan Gao, Xavier Intes

    Significance Fluorescence lifetime imaging in the short-wave infrared (SWIR) is expected to enable high resolution multiplexed molecular imaging in highly scattering tissue. Aim To characterize the brightness and fluorescence lifetime of commercially available organic SWIR fluorophores and benchmark them against the tail emission of conventional NIR-excited probes. Approach Characterization was performed through our established Time-domain Mesoscopic Fluorescence Molecular Tomography (TD-MFMT) system integrated around a TCSPC-SPAD array. Brightness and fluorescence lifetime was measured for NIR and SWIR probes above 1000 nm. Simultaneous probe imaging was then performed to assess their potential for multiplexed studies. Results NIR probes outperformed SWIR probes in brightness while the mean fluorescence lifetimes of the SWIR probes were extremely short. The phantom study demonstrated the feasibility of lifetime multiplexing in the SWIR window with both NIR and SWIR probes. Conclusions Long tail emission of NIR probes outperformed the SWIR probes in brightness beyond 1000 nm. Fluorescence lifetime was readily detectable in the SWIR window, where the SWIR probes showed shorter lifetimes compared to the NIR probes. We demonstrate the feasibility of lifetime multiplexing in the SWIR window, which paves the way for in vivo multiplexed studies of intact tissues at improved resolution.