Yun Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yun Song has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- André Messiaen
Laboratory for Plasma Physics, ERM/KMS, Brussels, Belgium
1 shared publication C.C. Zhu
School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026, People’s Republic of China
1 shared publication- Chao Yu
ASIPP - Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
1 shared publication - Frederic Durodié
Laboratory for Plasma Physics, LPP-ERM/KMS, 1000 Brussels, Belgium
1 shared publication G. Lombard
CEA, IRFM, F-13108, Saint Paul-lez-Durance, France
1 shared publication- Hao Xu
LinkedIn Corporation, Mountain View, CA, USA
1 shared publication
Latest Publications
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2031-2039
Optimization of Excitation Coil in Pulsed Eddy Current Testing of a Pipe Based on the Incident Field
Pulsed eddy current testing (PECT) is widely used to detect corrosion in industrial pipelines with coatings; however, the energy dissipation caused by liftoff limits the detection capability for small-sized pipes, especially the non-ferromagnetic pipes recently installed in various industrial scenarios. Since the magnetic field is not concentrated within non-ferromagnetic pipes due to their low permeability, energy dissipation is particularly large, which makes the PECT challenging. Aiming at such energy dissipation problem, this paper investigates the excitation process of PECT and proposes an optimization method for excitation coils. The proposed optimization aims to increase the incident field intensity, which is then decoupled from the PECT analytical solution, thereby allowing the solution to have only electromagnetic coupling relationship between the excitation coil and the specimen. Theoretical calculations are verified by the finite element method (FEM) simulations, followed by the experimental validation of optimized coils which verified their advantages in enhancing the specimen-related components in signals. Furthermore, PECT performance improvement is also discussed when the average incident field of different surfaces is enhanced. Results show that the coils designed based on the average incident field of modified footprint have good performance.
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2031-2039
Optimization of Excitation Coil in Pulsed Eddy Current Testing of a Pipe Based on the Incident Field
Pulsed eddy current testing (PECT) is widely used to detect corrosion in industrial pipelines with coatings; however, the energy dissipation caused by liftoff limits the detection capability for small-sized pipes, especially the non-ferromagnetic pipes recently installed in various industrial scenarios. Since the magnetic field is not concentrated within non-ferromagnetic pipes due to their low permeability, energy dissipation is particularly large, which makes the PECT challenging. Aiming at such energy dissipation problem, this paper investigates the excitation process of PECT and proposes an optimization method for excitation coils. The proposed optimization aims to increase the incident field intensity, which is then decoupled from the PECT analytical solution, thereby allowing the solution to have only electromagnetic coupling relationship between the excitation coil and the specimen. Theoretical calculations are verified by the finite element method (FEM) simulations, followed by the experimental validation of optimized coils which verified their advantages in enhancing the specimen-related components in signals. Furthermore, PECT performance improvement is also discussed when the average incident field of different surfaces is enhanced. Results show that the coils designed based on the average incident field of modified footprint have good performance.
- Open Access
Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
Nondestructive testing (NDT) is an essential method for assessing structural integrity in the oil and gas industry. Electromagnetic acoustic transducers (EMATs) have been extensively used to detect the wall-thickness reduction of plate-like structures, because they do not require direct contact. The pulse intervals of echoes are used to calculate the remnant thickness of structures. If the width of a single pulse is too large, multiple pulses will be superimposed, making it more difficult to extract the pulse interval. Thus, the width of a single pulse affects the resolution of measurements. This paper investigates the impacts of the backplate position on the pulse width and amplitude of thickness-measurement signals, using EMATs. By means of impedance modeling and measurement, it can be shown that the output impedance of the receiving coil is strongly influenced by the coil-backplate gap. With the increment in the coil-backplate gap, the signal amplitude and damping coefficient increase, while the self-resonant frequency decreases. By means of signal measurements on the specimen, it is shown that the pulse width and the signal amplitude can be significantly influenced by the backplate position. By reducing the coil–backplate gap, the pulse width can be reduced by over 80%, and by increasing the gap, the signal amplitude can be increased by over 300%. These research results can be used to optimize EMAT design, thereby suppressing the superposition of pulse echoes.
Open AccessStudy of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
Nondestructive testing (NDT) is an essential method for assessing structural integrity in the oil and gas industry. Electromagnetic acoustic transducers (EMATs) have been extensively used to detect the wall-thickness reduction of plate-like structures, because they do not require direct contact. The pulse intervals of echoes are used to calculate the remnant thickness of structures. If the width of a single pulse is too large, multiple pulses will be superimposed, making it more difficult to extract the pulse interval. Thus, the width of a single pulse affects the resolution of measurements. This paper investigates the impacts of the backplate position on the pulse width and amplitude of thickness-measurement signals, using EMATs. By means of impedance modeling and measurement, it can be shown that the output impedance of the receiving coil is strongly influenced by the coil-backplate gap. With the increment in the coil-backplate gap, the signal amplitude and damping coefficient increase, while the self-resonant frequency decreases. By means of signal measurements on the specimen, it is shown that the pulse width and the signal amplitude can be significantly influenced by the backplate position. By reducing the coil–backplate gap, the pulse width can be reduced by over 80%, and by increasing the gap, the signal amplitude can be increased by over 300%. These research results can be used to optimize EMAT design, thereby suppressing the superposition of pulse echoes.
- 1 July 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 168, 112615
RF network analysis of the WEST TWA mock-up in TITAN
- 1 July 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 168, 112615
RF network analysis of the WEST TWA mock-up in TITAN
- 1 April 2016
- Published by Elsevier in Fusion Engineering and Design
- Vol. 105, 15-21
Thermo-mechanical and damage analyses of EAST carbon divertor under type-I ELMy H-mode operation
- 1 April 2016
- Published by Elsevier in Fusion Engineering and Design
- Vol. 105, 15-21
Thermo-mechanical and damage analyses of EAST carbon divertor under type-I ELMy H-mode operation