Xue Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xue Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jin Yang
Chongqing University
3 shared publications - Liang Chen
State Key Laboratory of Coal Mine Disaster Dynamics and Control, Chongqing University, Chongqing 400044, China
2 shared publications - Luna Wang
State Key Laboratory of Coal Mine Disaster Dynamics and Control, Chongqing University, Chongqing 400044, China
2 shared publications - Zhiping Feng
State Key Laboratory of Coal Mine Disaster Dynamics and Control, Chongqing University, Chongqing 400044, China
2 shared publications - Gaoqiang Zhang
State Key Laboratory of Coal Mine Disaster Dynamics and Control, Chongqing University, Chongqing 400044, China
1 shared publication - Jianchao Zhang
College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
1 shared publication
Latest Publications
- Open Access
Echo Frequency Estimation Technology for Passive Surface Acoustic Wave Resonant Sensors Based on a Genetic Algorithm
Passive wireless surface acoustic wave (SAW) resonant sensors are widely used in measuring pressure, temperature, and torque, typically detecting sensing parameters by measuring the echo signal frequency of SAW resonators. Therefore, the accuracy of echo signal frequency estimation directly affects the performance index of the sensor. Due to the exponential attenuation trend of the echo signal, the duration is generally approximately 10 μs, with conventional frequency domain analysis methods limited by the sampling frequency and data points. Thus, the resolution of frequency estimation is limited. Here, signal time-domain fitting combined with a genetic algorithm is used to estimate SAW echo signal frequency. To address the problem of slow estimation speed and poor timeliness caused by a conventional genetic algorithm, which needs to simultaneously estimate multiple parameters, such as signal amplitude, phase, frequency, and envelope, the Hilbert transform is proposed to remove the signal envelope and estimate its amplitude, and the fast Fourier transform subsection method is used to analyze the initial phase of the signal. The genetic algorithm is thereby optimized to realize the frequency estimation of SAW echo signals under a single parameter. The developed digital signal processing frequency detection system was monitored in real time to estimate the frequency of an SAW echo signal lasting 10 μs and found to have only 100 sampling points. The proposed method has a frequency estimation error within 3 kHz and a frequency estimation time of less than 1 s, which is eight times faster than the conventional genetic algorithm.
Open AccessEcho Frequency Estimation Technology for Passive Surface Acoustic Wave Resonant Sensors Based on a Genetic Algorithm
Passive wireless surface acoustic wave (SAW) resonant sensors are widely used in measuring pressure, temperature, and torque, typically detecting sensing parameters by measuring the echo signal frequency of SAW resonators. Therefore, the accuracy of echo signal frequency estimation directly affects the performance index of the sensor. Due to the exponential attenuation trend of the echo signal, the duration is generally approximately 10 μs, with conventional frequency domain analysis methods limited by the sampling frequency and data points. Thus, the resolution of frequency estimation is limited. Here, signal time-domain fitting combined with a genetic algorithm is used to estimate SAW echo signal frequency. To address the problem of slow estimation speed and poor timeliness caused by a conventional genetic algorithm, which needs to simultaneously estimate multiple parameters, such as signal amplitude, phase, frequency, and envelope, the Hilbert transform is proposed to remove the signal envelope and estimate its amplitude, and the fast Fourier transform subsection method is used to analyze the initial phase of the signal. The genetic algorithm is thereby optimized to realize the frequency estimation of SAW echo signals under a single parameter. The developed digital signal processing frequency detection system was monitored in real time to estimate the frequency of an SAW echo signal lasting 10 μs and found to have only 100 sampling points. The proposed method has a frequency estimation error within 3 kHz and a frequency estimation time of less than 1 s, which is eight times faster than the conventional genetic algorithm.
- Open Access
Flexible Sensors Array Based on Frosted Microstructured Ecoflex Film and TPU Nanofibers for Epidermal Pulse Wave Monitoring
Recent advances in flexible pressure sensors have fueled increasing attention as promising technologies with which to realize human epidermal pulse wave monitoring for the early diagnosis and prevention of cardiovascular diseases. However, strict requirements of a single sensor on the arterial position make it difficult to meet the practical application scenarios. Herein, based on three single-electrode sensors with small area, a 3 × 1 flexible pressure sensor array was developed to enable measurement of epidermal pulse waves at different local positions of radial artery. The designed single sensor holds an area of 6 × 6 mm2, which mainly consists of frosted microstructured Ecoflex film and thermoplastic polyurethane (TPU) nanofibers. The Ecoflex film was formed by spinning Ecoflex solution onto a sandpaper surface. Micropatterned TPU nanofibers were prepared on a fluorinated ethylene propylene (FEP) film surface using the electrospinning method. The combination of frosted microstructure and nanofibers provides an increase in the contact separation of the tribopair, which is of great benefit for improving sensor performance. Due to this structure design, the single small-area sensor was characterized by pressure sensitivity of 0.14 V/kPa, a response time of 22 ms, a wide frequency band ranging from 1 to 23 Hz, and stability up to 7000 cycles. Given this output performance, the fabricated sensor can detect subtle physiological signals (e.g., respiration, ballistocardiogram, and heartbeat) and body movement. More importantly, the sensor can be utilized in capturing human epidermal pulse waves with rich details, and the consistency of each cycle in the same measurement is as high as 0.9987. The 3 × 1 flexible sensor array is employed to acquire pulse waves at different local positions of the radial artery. In addition, the time domain parameters including pulse wave transmission time (PTT) and pulse wave velocity (PWV) can be obtained successfully, which holds promising potential in pulse-based cardiovascular system status monitoring.
Open AccessFlexible Sensors Array Based on Frosted Microstructured Ecoflex Film and TPU Nanofibers for Epidermal Pulse Wave Monitoring
Recent advances in flexible pressure sensors have fueled increasing attention as promising technologies with which to realize human epidermal pulse wave monitoring for the early diagnosis and prevention of cardiovascular diseases. However, strict requirements of a single sensor on the arterial position make it difficult to meet the practical application scenarios. Herein, based on three single-electrode sensors with small area, a 3 × 1 flexible pressure sensor array was developed to enable measurement of epidermal pulse waves at different local positions of radial artery. The designed single sensor holds an area of 6 × 6 mm2, which mainly consists of frosted microstructured Ecoflex film and thermoplastic polyurethane (TPU) nanofibers. The Ecoflex film was formed by spinning Ecoflex solution onto a sandpaper surface. Micropatterned TPU nanofibers were prepared on a fluorinated ethylene propylene (FEP) film surface using the electrospinning method. The combination of frosted microstructure and nanofibers provides an increase in the contact separation of the tribopair, which is of great benefit for improving sensor performance. Due to this structure design, the single small-area sensor was characterized by pressure sensitivity of 0.14 V/kPa, a response time of 22 ms, a wide frequency band ranging from 1 to 23 Hz, and stability up to 7000 cycles. Given this output performance, the fabricated sensor can detect subtle physiological signals (e.g., respiration, ballistocardiogram, and heartbeat) and body movement. More importantly, the sensor can be utilized in capturing human epidermal pulse waves with rich details, and the consistency of each cycle in the same measurement is as high as 0.9987. The 3 × 1 flexible sensor array is employed to acquire pulse waves at different local positions of the radial artery. In addition, the time domain parameters including pulse wave transmission time (PTT) and pulse wave velocity (PWV) can be obtained successfully, which holds promising potential in pulse-based cardiovascular system status monitoring.
- Open Access
A Flexible Pressure Sensor with a Mesh Structure Formed by Lost Hair for Human Epidermal Pulse Wave Monitoring
Flexible pressure sensors with the capability of monitoring human vital signs show broad application prospects in personalized healthcare. In this work, a hair-based flexible pressure sensor (HBPS) consisting of lost hair and polymer films was proposed for the continuous monitoring of the human epidermal arterial pulse waveform. A macroscale mesh structure formed by lost hair provides a simplified spacer that endows the triboelectric-based flexible pressure sensor with sufficient contact–separation space. Based on this mesh structure design, the hair-based flexible pressure sensor can respond to the slight pressure change caused by an object with 5 mg weight and hold a stable output voltage under 1–30 Hz external pressure excitation. Additionally, the hair-based flexible pressure sensor showed great sensitivity (0.9 V/kPa) and decent stability after 4500 cycles of operation. Given these compelling features, the HBPS can successfully measure the human epidermal arterial pulses with obvious details at different arteries. The proposed HBPS can also be used to monitor the pulse signals of different subjects. Furthermore, the three different pulse wave transmission time (PTT) values (PTT-foot, PTT-middle, and PTT-peak) can be obtained by simultaneously monitoring human pulse and electrocardiogram signals, which has enormous application potential for assessing cardiovascular system health.
Open AccessA Flexible Pressure Sensor with a Mesh Structure Formed by Lost Hair for Human Epidermal Pulse Wave Monitoring
Flexible pressure sensors with the capability of monitoring human vital signs show broad application prospects in personalized healthcare. In this work, a hair-based flexible pressure sensor (HBPS) consisting of lost hair and polymer films was proposed for the continuous monitoring of the human epidermal arterial pulse waveform. A macroscale mesh structure formed by lost hair provides a simplified spacer that endows the triboelectric-based flexible pressure sensor with sufficient contact–separation space. Based on this mesh structure design, the hair-based flexible pressure sensor can respond to the slight pressure change caused by an object with 5 mg weight and hold a stable output voltage under 1–30 Hz external pressure excitation. Additionally, the hair-based flexible pressure sensor showed great sensitivity (0.9 V/kPa) and decent stability after 4500 cycles of operation. Given these compelling features, the HBPS can successfully measure the human epidermal arterial pulses with obvious details at different arteries. The proposed HBPS can also be used to monitor the pulse signals of different subjects. Furthermore, the three different pulse wave transmission time (PTT) values (PTT-foot, PTT-middle, and PTT-peak) can be obtained by simultaneously monitoring human pulse and electrocardiogram signals, which has enormous application potential for assessing cardiovascular system health.