Jiande Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiande Zhang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Baoliang Qian
College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha, Hunan, CHINA
2 shared publications Bing Bai
Xi’an Electronic Engineering Research Institute 3 , Xi’an 710100, China
1 shared publication- Bo Zhao
School of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou, China
1 shared publication Che-Bo Liu
Department of Applied Physics, National University of Defense Technology, Changsha 410073, Hunan, People’s Republic of China
1 shared publicationChuan-Lu Li
Department of Applied Physics, National University of Defense Technology, Changsha 410073, Hunan, People’s Republic of China
1 shared publicationCun-Hua Liu
Department of Applied Physics, National University of Defense Technology, Changsha 410073, Hunan, People’s Republic of China
1 shared publication
Latest Publications
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Ku-band 300 kW high power ferrite phase shifter
Phase shifter (PS) is a key component of a phased array antenna (PAA) system, which controls the microwave phase and realizes the antenna beam forming and scanning. A ferrite PS (FPS) is a current-controlled PS that uses the ferrite’s gyromagnetic properties to realize phase shifting. It has the advantages of short phase switching time, low microwave loss, and high reliability and, therefore, has been widely used in low-power PAA systems. However, the power handling capability of the traditional Ku-band FPS is only a few kW, prohibiting FPS from being used in high-power microwave (HPM) PAA systems. Spurred by this concern, this paper proposes a new dual-toroid FPS structure with an external magnetic excitation. By optimizing the PS configuration, improving the integration process, and enhancing the performance of ferrite materials, a single FPS in the Ku band has reached the power handling capability of more than 300 kW with an insertion loss of less than −1.2 dB, the phase shift range of 0°–360°, the width less than 11.5 mm, and the ability of a one-dimensional array. The FPS has the potential to be used in the PAA of an HPM system, laying a foundation for the research of the HPM PAA system.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Ku-band 300 kW high power ferrite phase shifter
Phase shifter (PS) is a key component of a phased array antenna (PAA) system, which controls the microwave phase and realizes the antenna beam forming and scanning. A ferrite PS (FPS) is a current-controlled PS that uses the ferrite’s gyromagnetic properties to realize phase shifting. It has the advantages of short phase switching time, low microwave loss, and high reliability and, therefore, has been widely used in low-power PAA systems. However, the power handling capability of the traditional Ku-band FPS is only a few kW, prohibiting FPS from being used in high-power microwave (HPM) PAA systems. Spurred by this concern, this paper proposes a new dual-toroid FPS structure with an external magnetic excitation. By optimizing the PS configuration, improving the integration process, and enhancing the performance of ferrite materials, a single FPS in the Ku band has reached the power handling capability of more than 300 kW with an insertion loss of less than −1.2 dB, the phase shift range of 0°–360°, the width less than 11.5 mm, and the ability of a one-dimensional array. The FPS has the potential to be used in the PAA of an HPM system, laying a foundation for the research of the HPM PAA system.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (2)
Preliminary study of dual annular multiple-beam cathode for V-band coaxial transit-time oscillator
Since the research toward high-power millimeter-wave generator becomes a tendency in high-power microwave, overmoded structure with the high-order mode has been a considerable interest because of its potential to increase power handling capacity (PHC). To expand the PHC of V-band transit-time oscillator and excite higher mode TM03, a dual annular multiple-beam cathode has been proposed. In the geometric structure of the dual annular multiple-beam diode, cathode rods around two concentric circles are uniformly placed on cathode base, and each circle has several graphite rods. Because of space charge shielding effect and fluctuation of electron beam, explosive emission current of inner and outer cathode circles is difficult to be balanced, and the electron beam transmission rate is not very high. To solve those two problems, the relative length (ΔL) and the relative radius (Δr) between the inner and outer cathode circles are optimized to obtain balanced currents of inner and outer beams and a good transmission rate. In this paper, the preliminary study of a dual annular multiple-beam cathode is carried out by optimizing the cathode structure. When ΔL and Δr are equal to 2.5 and 4 mm, respectively, the dual annular multiple-beams cathode can provide 2.71 kA uniform intense relativistic electron beams under 421 kV, and the magnetic field is 1.2T. As a simulation result, explosively emitted and the 95.2% of total beam current transmission rate can be reached.
- 1 February 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (2)
Open AccessPreliminary study of dual annular multiple-beam cathode for V-band coaxial transit-time oscillator
Since the research toward high-power millimeter-wave generator becomes a tendency in high-power microwave, overmoded structure with the high-order mode has been a considerable interest because of its potential to increase power handling capacity (PHC). To expand the PHC of V-band transit-time oscillator and excite higher mode TM03, a dual annular multiple-beam cathode has been proposed. In the geometric structure of the dual annular multiple-beam diode, cathode rods around two concentric circles are uniformly placed on cathode base, and each circle has several graphite rods. Because of space charge shielding effect and fluctuation of electron beam, explosive emission current of inner and outer cathode circles is difficult to be balanced, and the electron beam transmission rate is not very high. To solve those two problems, the relative length (ΔL) and the relative radius (Δr) between the inner and outer cathode circles are optimized to obtain balanced currents of inner and outer beams and a good transmission rate. In this paper, the preliminary study of a dual annular multiple-beam cathode is carried out by optimizing the cathode structure. When ΔL and Δr are equal to 2.5 and 4 mm, respectively, the dual annular multiple-beams cathode can provide 2.71 kA uniform intense relativistic electron beams under 421 kV, and the magnetic field is 1.2T. As a simulation result, explosively emitted and the 95.2% of total beam current transmission rate can be reached.
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 124704
Development of a high-power pulse-forming network Marx generator with a long pulse duration
To meet the application needs for producing long-pulse electron beams and high-power microwaves, a pulse-forming network Marx generator with a pulse duration of 260 ns is presented in this paper. This generator is composed of 20 stages of pulse-forming network modules. Each module is formed with nine capacitors connected in parallel. The generator functions at 44 kV, which is lower than the rated voltage of the mica paper capacitor, to improve the lifetime. The impedance of the generator is designed to reach 45 Ω. To avoid the strong coupling between the adjacent stages, the physical layout of the generator adopts a zigzag design. The generator is housed in a gas pressurized vessel of 600 mm in diameter and 580 mm in length. Across a 50 Ω load, it can deliver quasi-rectangular pulses with a pulse duration of 260 ns and an amplitude of 500 kV for a single shot. The output pulse features a plateau duration of 160 ns and a leading edge of 45 ns. In burst mode, it can steadily output ten pulses of 450 kV at a repetition rate of 10 Hz on either a resistive load or a diode.
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 124704
Development of a high-power pulse-forming network Marx generator with a long pulse duration
To meet the application needs for producing long-pulse electron beams and high-power microwaves, a pulse-forming network Marx generator with a pulse duration of 260 ns is presented in this paper. This generator is composed of 20 stages of pulse-forming network modules. Each module is formed with nine capacitors connected in parallel. The generator functions at 44 kV, which is lower than the rated voltage of the mica paper capacitor, to improve the lifetime. The impedance of the generator is designed to reach 45 Ω. To avoid the strong coupling between the adjacent stages, the physical layout of the generator adopts a zigzag design. The generator is housed in a gas pressurized vessel of 600 mm in diameter and 580 mm in length. Across a 50 Ω load, it can deliver quasi-rectangular pulses with a pulse duration of 260 ns and an amplitude of 500 kV for a single shot. The output pulse features a plateau duration of 160 ns and a leading edge of 45 ns. In burst mode, it can steadily output ten pulses of 450 kV at a repetition rate of 10 Hz on either a resistive load or a diode.
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 131-684
Accurate measurement of strain parameters for spacecraft structure based on optical fiber sensing
In order to achieve the high accuracy measurement of strain parameters of spacecraft structure with optical fiber sensors, a demodulation approach based on the composite wavelength reference of Fabry-Perot(F-P) etalon and acetylene(C2H2) gas cell is presented. In the approach, an adaptive threshold method is used to resolve the difficulty of peaks searching of F-P etalon waveform, which is caused by poor flatness of light source. Meanwhile, the strain sensitivity coefficient of optical fiber sensors is accurately obtained by a two-step method, so as to eliminate the influences of the sensor substrate and the bonding layer on the measurement. Finally, the measuring results of strain sensors are compensated with the temperature sensor to improve the measurement precision of strain parameters. The experiments results show that when the temperature variation range is 85°C(-25°C~60°C), the FBG wavelength demodulation deviation of the approach in this paper is within 3pm, while the relative measuring error of strain parameters is within 4%, which can realize the stable and high-precision measurement of the strain parameters of spacecraft structure.
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 131-684
Accurate measurement of strain parameters for spacecraft structure based on optical fiber sensing
In order to achieve the high accuracy measurement of strain parameters of spacecraft structure with optical fiber sensors, a demodulation approach based on the composite wavelength reference of Fabry-Perot(F-P) etalon and acetylene(C2H2) gas cell is presented. In the approach, an adaptive threshold method is used to resolve the difficulty of peaks searching of F-P etalon waveform, which is caused by poor flatness of light source. Meanwhile, the strain sensitivity coefficient of optical fiber sensors is accurately obtained by a two-step method, so as to eliminate the influences of the sensor substrate and the bonding layer on the measurement. Finally, the measuring results of strain sensors are compensated with the temperature sensor to improve the measurement precision of strain parameters. The experiments results show that when the temperature variation range is 85°C(-25°C~60°C), the FBG wavelength demodulation deviation of the approach in this paper is within 3pm, while the relative measuring error of strain parameters is within 4%, which can realize the stable and high-precision measurement of the strain parameters of spacecraft structure.
- 24 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (10) , 4512-4517
Development of a GW-Level Solid-State Long Pulse Generator
- 24 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (10) , 4512-4517
Development of a GW-Level Solid-State Long Pulse Generator
- 1 September 2000
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 88 (5) , 3059-3063
Experiment on the plasma-loaded backward-wave oscillator using a gas-loaded foil-less diode
High-power microwave radiation of 9.5–13.4 GHz was generated in a plasma-loaded backward-wave oscillator employing a relativistic electron beam of 400–500 keV and 1–3 kA. This experiment was to re-examine and confirm the previous works that had been done in other various institutions. The relativistic electron beam, which was produced from a helium gas-loaded foil-less diode, was injected into the helium gas-loaded rippled-wall waveguide of the backward-wave oscillator, generating a plasma in the waveguide and then the high-power microwave radiation. A sharp increase in the output microwave power has been observed in a narrow range of the helium gas pressure, and two dips in the microwave emission have also been found in a certain range of the axial magnetic field. Additionally, at certain values of the helium gas pressure and guide magnetic field, the total microwave emission of the plasma-loaded backward-wave oscillator was found to be seven times as large as that of the vacuum case. The highest interaction efficiency was estimated to be about 29% for the present experiment.
- 1 September 2000
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 88 (5) , 3059-3063
Experiment on the plasma-loaded backward-wave oscillator using a gas-loaded foil-less diode
High-power microwave radiation of 9.5–13.4 GHz was generated in a plasma-loaded backward-wave oscillator employing a relativistic electron beam of 400–500 keV and 1–3 kA. This experiment was to re-examine and confirm the previous works that had been done in other various institutions. The relativistic electron beam, which was produced from a helium gas-loaded foil-less diode, was injected into the helium gas-loaded rippled-wall waveguide of the backward-wave oscillator, generating a plasma in the waveguide and then the high-power microwave radiation. A sharp increase in the output microwave power has been observed in a narrow range of the helium gas pressure, and two dips in the microwave emission have also been found in a certain range of the axial magnetic field. Additionally, at certain values of the helium gas pressure and guide magnetic field, the total microwave emission of the plasma-loaded backward-wave oscillator was found to be seven times as large as that of the vacuum case. The highest interaction efficiency was estimated to be about 29% for the present experiment.