Yongrui Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yongrui Guo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Nana Zhang
College of Optoelectronics Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China
3 shared publications Hongxin Wang
School of Optoelectronic Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China
1 shared publicationHuiqi Yang
School of Artificial Intelligence, Chongqing Technology and Business University, Chongqing, China
1 shared publicationJunhong Yu
School of Optoelectronic Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China
1 shared publicationLei Huang
School of Optoelectronic Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China
1 shared publicationPengliang Guo
Department of Physics Taiyuan Normal University Taiyuan 030619 China
1 shared publication
Latest Publications
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (18) , 1141-1144
Estimation Method for Surface and Medium Loss of Fabry-Pérot Etalon
Fabry-Pérot (FP) etalon is widely applied in experimental research across various fields. In most experiments, the etalon is generally regarded as an ideal optical device. However, if there is any loss in the FP etalon, its parameters including transmittance, linewidth, and finesse will be affected, which will in turn affect the experimental results. In this paper, we propose an estimation method for surface and medium losses of FP etalon. When the FP etalon is not filled with any medium, we establish a relationship between the peak transmittance of the etalon and the surface loss through theoretical calculations. When the FP etalon is filled with a medium, we derive a relationship between the peak transmittance of the etalon and both the surface and the medium loss through calculations. The two functional relationships we established provide a theoretical foundation for experimental measurements of the surface and medium loss of the FP etalon. Based on these functional relationships, we propose a method for estimating the surface and medium losses of FP etalon. Our loss estimation method is also applicable to the FP interferometer.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (18) , 1141-1144
Estimation Method for Surface and Medium Loss of Fabry-Pérot Etalon
Fabry-Pérot (FP) etalon is widely applied in experimental research across various fields. In most experiments, the etalon is generally regarded as an ideal optical device. However, if there is any loss in the FP etalon, its parameters including transmittance, linewidth, and finesse will be affected, which will in turn affect the experimental results. In this paper, we propose an estimation method for surface and medium losses of FP etalon. When the FP etalon is not filled with any medium, we establish a relationship between the peak transmittance of the etalon and the surface loss through theoretical calculations. When the FP etalon is filled with a medium, we derive a relationship between the peak transmittance of the etalon and both the surface and the medium loss through calculations. The two functional relationships we established provide a theoretical foundation for experimental measurements of the surface and medium loss of the FP etalon. Based on these functional relationships, we propose a method for estimating the surface and medium losses of FP etalon. Our loss estimation method is also applicable to the FP interferometer.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 59 (2) , 1-6
Stimulated Emission Cross-Section Measurement for Laser Crystals of High-Power Solid-State Lasers Using Relaxation Oscillation Frequency
We demonstrate a new method for measuring the stimulated emission cross-section ( $\sigma _{s}$ ) of laser crystals for high-power solid-state lasers at working state using the relaxation oscillation frequency (ROF). The method is implemented by measuring the ROF of the laser together with making the relation curve between the ROF and $\sigma _{s}$ of the laser. The stimulated emission cross-section of the laser crystal can be obtained when the ROF in the relation curve equals to that of the measured value. Employing the method, the actual $\sigma _{s}$ of the Nd:YVO4 crystals with doping concentrations and pumping powers of 0.2 at.% and 51.5 W at 808 nm, 0.8 at.% and 80 W at 888 nm, and 0.8 at.% and 113 W at 888 nm are measured upon considering the influence of concentration quenching and energy transfer upconversion of the lasers. The measured results are $23.34\times 10^{-19}$ , $23.77\times 10^{-19}$ , and $23.42\times 10^{-19}$ cm2, respectively. The results are further compared and analysed with considering the temperature gradient of the laser crystals. It is found that the anomalous temperature gradient of the laser crystal at working state can induce an inhomogeneous gain spectral broadening, which can severely impact $\sigma _{s}$ of the laser crystal.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 59 (2) , 1-6
Stimulated Emission Cross-Section Measurement for Laser Crystals of High-Power Solid-State Lasers Using Relaxation Oscillation Frequency
We demonstrate a new method for measuring the stimulated emission cross-section ( $\sigma _{s}$ ) of laser crystals for high-power solid-state lasers at working state using the relaxation oscillation frequency (ROF). The method is implemented by measuring the ROF of the laser together with making the relation curve between the ROF and $\sigma _{s}$ of the laser. The stimulated emission cross-section of the laser crystal can be obtained when the ROF in the relation curve equals to that of the measured value. Employing the method, the actual $\sigma _{s}$ of the Nd:YVO4 crystals with doping concentrations and pumping powers of 0.2 at.% and 51.5 W at 808 nm, 0.8 at.% and 80 W at 888 nm, and 0.8 at.% and 113 W at 888 nm are measured upon considering the influence of concentration quenching and energy transfer upconversion of the lasers. The measured results are $23.34\times 10^{-19}$ , $23.77\times 10^{-19}$ , and $23.42\times 10^{-19}$ cm2, respectively. The results are further compared and analysed with considering the temperature gradient of the laser crystals. It is found that the anomalous temperature gradient of the laser crystal at working state can induce an inhomogeneous gain spectral broadening, which can severely impact $\sigma _{s}$ of the laser crystal.
- 14 December 2022
- Published by Wiley in Annalen der Physik
- Vol. 535 (1)
Quantum‐Error‐Rejection for Hyperentanglement Transmission without Calibrated Reference Frames
In quantum communication, the channel noise and the misalignment of the reference frames between the communication parties will lead to the failure of quantum state transmission. Here an alignment‐free spatial‐polarization hyperentanglement transmission scheme is provided for hyperentangled photons. In this scheme, before the spatial‐polarization hyperentanglement is transmitted through the fiber channel, it is first encoded as a time‐bin entanglement with the same polarization. After the photons pass through the noise channel, the polarization errors caused by reference frames misalignment and channel noise can be corrected by time‐bin entanglement. In principle, by implementing this scheme, the communication parties can share the original hyperentangled state, and the success probability can approach unity. The scheme is robust to random channel noise and reference frames misalignment, and the decoherence effect caused by the misalignment of the reference frames between the communication parties can be completely suppressed by implementing this scheme.
- 14 December 2022
- Published by Wiley in Annalen der Physik
- Vol. 535 (1)
Quantum‐Error‐Rejection for Hyperentanglement Transmission without Calibrated Reference Frames
In quantum communication, the channel noise and the misalignment of the reference frames between the communication parties will lead to the failure of quantum state transmission. Here an alignment‐free spatial‐polarization hyperentanglement transmission scheme is provided for hyperentangled photons. In this scheme, before the spatial‐polarization hyperentanglement is transmitted through the fiber channel, it is first encoded as a time‐bin entanglement with the same polarization. After the photons pass through the noise channel, the polarization errors caused by reference frames misalignment and channel noise can be corrected by time‐bin entanglement. In principle, by implementing this scheme, the communication parties can share the original hyperentangled state, and the success probability can approach unity. The scheme is robust to random channel noise and reference frames misalignment, and the decoherence effect caused by the misalignment of the reference frames between the communication parties can be completely suppressed by implementing this scheme.