Dino Vasquez

Dino Vasquez

*This is an algorithmically generated author record based on publicly available information.

Dino Vasquez has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessing the Effect of Insulation Materials Used for Energy Conservation in Buildings on Indoor Radon—The Scale Model Room Approach

    by Ilaria Rocchetti, Manuela Portaro, Paola Tuccimei, Gianfranco Galli, Michele Soligo, Cristina Longoni, Dino Vasquez

    This study investigates how external insulation materials used for energy efficiency affect indoor radon accumulation, using a scale model room built with ignimbrite, a highly radon-emitting volcanic rock. Two insulation materials—mineral wool (open-cell, 98% porosity) and extruded polystyrene (XPS, closed-cell, >95%)—were applied to the outer walls of the model room. Their effects were tested in combination with three internal radon barriers (silane-terminated membrane, silicone sealant, bitumen membrane) and under varying ventilation rates (0.11 h−1 and 0.44 h−1). Radon concentrations were measured using calibrated detectors over five experimental phases. Without ventilation, XPS increased indoor radon by up to +351%, while mineral wool showed a milder effect (+26%). The silicone sealant reduced radon by up to 90%, outperforming other barriers. Ventilation significantly lowered radon levels, simulating the “flushing” effect of wind. The combination of impermeable insulation and lack of air exchange led to the highest radon accumulation. High-performance insulation can compromise indoor air quality by trapping radon, especially in buildings with high geogenic radon potential. Effective mitigation requires pairing insulation with high-performing radon barriers and adequate ventilation. These findings highlight the need to balance energy efficiency with indoor environmental safety.


  • Open Access

    A new methodology for the evaluation of radon diffusion coefficients in anti-radon membranes

    by Manuela Portaro, Ilaria Rocchetti, Gianfranco Galli, Paola Tuccimei, Michele Soligo, Cristina Longoni, Dino Vasquez


  • Open Access

    The Scale Model Room Approach to Test the Performance of Airtight Membranes to Control Indoor Radon Levels and Radiation Exposure

    by Manuela Portaro, Ilaria Rocchetti, Paola Tuccimei, Gianfranco Galli, Michele Soligo, Cristina Longoni, Dino Vasquez

    Indoor radon is one of the most significant contributors to lung cancer after smoking. Mitigation strategies based on protecting buildings with radon barrier materials, combined with home ventilation or room pressurization, are regularly used. A scale model room made from a porous ignimbrite rich in radon precursors was used as an analogue to test the efficiency of fifteen airtight membranes to reduce radon levels, also in combination with room pressurization. The results of these experiments were considered together with previous ones to propose the scale model room approach as a tool for rapidly evaluating the performance of specially designed radon barrier materials, and for radiation exposure assessment. Relative reduction of indoor radon (RIR) ranges from −20 to −94%. The most effective materials were FPO membrane, single-component silane-terminated polymer membranes and synthetic resins. The presence of additives likely modified the composition and structure of some products, improving their radon barrier capacity. The introduction of room pressurization further reduced radon levels in the model room where the membranes were applied. The overpressure necessary to reach RIRs of the order of 85–90% is very low for materials that powerfully stop radon even without ventilation, but necessarily higher for poorer membranes.


  • Open Access

    Indoor Radon Surveying and Mitigation in the Case-Study of Celleno Town (Central Italy) Located in a Medium Geogenic Radon Potential Area

    by Manuela Portaro, Ilaria Rocchetti, Paola Tuccimei, Gianfranco Galli, Michele Soligo, Giancarlo Ciotoli, Cristina Longoni, Dino Vasquez, Federica Sola

    Indoor radon surveying and remediation were implemented in a single-family home affected by high levels of indoor radon in the Celleno municipality (central Italy) with the aim of identifying the contribution of radon sources, evaluating the factors affecting radon entry into the building, and reducing radon risk. Average radon levels were relatively low at the ground floor (286 ± 202 Bq m−3) and first floor (167 ± 84 Bq m−3) in autumn when the temperature was still warm and the windows were open, but increased up to 2776 ± 1768 Bq m−3 and 970 ± 202 Bq m−3 in the first half of December, when the heating system was on and the windows were closed. The inner walls of the pilot room at the ground floor, semi buried on one side, were then treated with a waterproof product (a silane terminated polymer) and the average radon was halved (1475 ± 1092 Bq m−3) in the following month, which was still characterised by winter conditions. Radon entry in the room was identified and sealed with the same product, and a radon accumulation space behind a NE-SW oriented wall was naturally ventilated, reducing radon below the reference level in April with northerly winds conditions.


  • Open Access

    Testing the Properties of Radon Barrier Materials and Home Ventilation to Mitigate Indoor Radon

    by Manuela Portaro, Paola Tuccimei, Gianfranco Galli, Michele Soligo, Cristina Longoni, Dino Vasquez

    Indoor radon is the second cause of lung cancer. Mitigation strategies are based on (i) building protection with radon barrier materials, (ii) increasing home ventilation or (iii) room pressurization. A scale model room created with a porous ignimbrite rich in radon precursors was used as an analogue to test the indoor radon reduction ability of various radon barrier materials in a real room. The properties of these materials were tested with and without room pressurization by introducing outdoor air at different flow rates. The best materials reduced indoor radon up to 80% and, when the highest pressurization was applied, to 93%.