Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrzej Lejczak has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Analysis of Gait Kinematics in Older Adults: Free Walking vs. Nordic Walking with Classic and Mechatronic Poles

    by Agnieszka Szpala, Sławomir Winiarski, Małgorzata Kołodziej, Bogdan Pietraszewski, Ryszard Jasiński, Tadeusz Niebudek, Andrzej Lejczak, Karolina Lorek, Jacek Bałchanowski, Sławomir Wudarczyk, et al.

    This investigation aimed to scrutinise the kinematic and spatio-temporal characteristics of free and Nordic walking (NW) in older adults, utilising both traditional and biosensor-integrated mechatronic poles. The hypothesis was that including biosensors for gait analysis in NW poles would not disrupt the walking pattern of older adults compared to standard poles. The study involved seniors aged 65–74 who were amateur Nordic Walking (NW) practitioners. They were instructed to traverse a 100-m distance three times: without poles, with traditional NW poles, and with mechatronic poles. The MyoMOTION MR3 system was used to gather biomechanical data. The study revealed differences in eight kinematic parameters and stride time between free walking and walking with poles. However, no statistically significant differences were observed in any of the parameters, regardless of the pole type used. The findings suggest that older NW practitioners tend to employ free walking patterns even when using poles.


  • Open Access

    Do Mechatronic Poles Change the Gait Technique of Nordic Walking in Patients with Ischemic Heart Disease?

    by Agnieszka Szpala, Sławomir Winiarski, Małgorzata Kołodziej, Bogdan Pietraszewski, Ryszard Jasiński, Tadeusz Niebudek, Andrzej Lejczak, Dariusz Kałka, Karolina Lorek, Krzysztof Bałchanowski, et al.

    The study aimed to compare the technique of normal gait with the Nordic walking (NW) gait with classical and mechatronic poles in patients with ischemic heart disease. It was assumed that equipping classical NW poles with sensors enabling biomechanical gait analysis would not cause a change in the gait pattern. The study involved 12 men suffering from ischemic heart disease (age: 66.2 ± 5.2 years, body height: 173.8 ± 6.74 cm; body mass: 87.3 ± 10.89 kg; disease duration: 12.2 ± 7.5 years). The MyoMOTION 3D inertial motion capture system (Noraxon Inc., Scottsdale, AZ, USA) was used to collect biomechanical variables of gait (spatiotemporal and kinematic parameters). The subject’s task was to cover the 100 m distance with three types of gait-walking without poles (normal gait), walking with classical poles to NW, and walking with mechatronic poles from the so-called preferred velocity. Parameters were measured on the right and left sides of the body. The data were analyzed using two-way repeated measures analysis of variance with the between-subject factor “body side.” Friedman’s test was used when necessary. For most kinematic parameters, with the exception of knee flexion–extension ( ) and shoulder flexion–extension ( ), significant differences were found between normal and walking with poles for both the left and right side of the body and no differences due to the type of pole. Differences between the left and right movement ranges were identified only for the ankle inversion–eversion parameter (gait without poles ; gait with classical poles ). In the case of spatiotemporal parameters, a reduction in the cadence step value using mechatronic poles and the stance phase using classical poles compared to normal walking was observed. There was also an increase in the values for step length and step time regardless of the type of poles, stride length, and swing phase when using classical poles and stride time when using mechatronic poles. The differences between the right and left sides of the measurement occurred when walking with both types of poles for single support (gait with classical poles ; gait with mechatronic poles ), stance phase (gait with classical poles ; gait with mechatronic poles ) and swing phase (gait with classical poles ; gait with mechatronic poles ). Mechatronic poles can be used in the study of the biomechanics of gait in real-time with feedback on its regularity because no statistically significant differences were found between the NW gait with classical and mechatronic poles in the studied men with ischemic heart disease.


  • Open Access

    No Influence of Mechatronic Poles on the Movement Pattern of Professional Nordic Walkers

    by Agnieszka Szpala, Sławomir Winiarski, Małgorzata Kołodziej, Bogdan Pietraszewski, Ryszard Jasiński, Tadeusz Niebudek, Andrzej Lejczak, Karolina Lorek, Jacek Bałchanowski, Sławomir Wudarczyk, et al.

    This study compared selected temporal and kinematic parameters of normal gait and Nordic Walking (NW) performed with classic and mechatronic poles (classic poles equipped with sensors). It was assumed that equipping NW poles with sensors for biomechanical gait analysis would not impair the NW walking technique. Six professional NW instructors and athletes, including three women, participated in the study. The MyoMotion MR3 motion analysis system was used to collect gait kinematic variables. The subject’s task was to cover a 100-m distance with three types of gait: a gait without poles, a gait with classic NW poles, and a gait with mechatronic poles at the preferred speed. Parameters were measured both on the right and left sides of the body. No significant differences were found between gait types for three temporal parameters: step cadence, step, and stride time. For the other variables, all the differences identified were between free-walking and walking with poles, with no differences between standard and mechatronic poles. For nine kinematic parameters, differences between free-walking and walking with poles for both the left and right sides were found, while no differences were due to the pole type. All temporal parameters were characterized by symmetry, while among kinematic parameters, only two were asymmetrical (shoulder abduction–adduction in walking with regular poles and elbow flexion–extension in walking without poles). Equipping classic NW poles with additional signaling and measuring devices (mechatronic poles) does not impair the NW technique, making it possible to use them in further studies of gait biomechanics.