MIMohannad Ibrahim

Mohannad Ibrahim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohannad Ibrahim has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of Parameterized Quantum Circuits With Cross-Resonance Pulse-Driven Entanglers

    by Mohannad M. Ibrahim, Hamed Mohammadbagherpoor, Cynthia Rios, Nicholas T. Bronn, Gregory T. Byrd

    Variational Quantum Algorithms (VQAs) have emerged as a powerful class of algorithms that is highly suitable for noisy quantum devices. Therefore, investigating their design has become key in quantum computing research. Previous works have shown that choosing an effective parameterized quantum circuit (PQC) or ansatz for a VQA is crucial to its overall performance, especially on near-term devices. In this paper, we utilize pulse-level access to quantum machines, our understanding of their two-qubit interactions, and, more importantly, our knowledge of VQAs, to customize the design of two-qubit entanglers. Our analysis shows that utilizing customized pulse gates for ansatze reduces state preparation times by more than half, maintains expressibility relative to standard ansatze, and produces PQCs that are more trainable through local cost function analysis. Our algorithm performance results show that in three cases, our PQC configuration outperforms the base implementation. Experiments using IBM Quantum hardware demonstrate that our pulse-based PQC configurations are more capable of solving MaxCut and Chemistry problems compared to a standard configuration.


  • Contrast Pediatric Brain Perfusion

    by Mohannad Ibrahim, Talha Ul Ghazi, Jayapalli Rajiv Bapuraj, Ashok Srinivasan


  • Optimizing Craniofacial CT Technique

    by Hemant A. Parmar, Mohannad Ibrahim, Suresh K. Mukherji


  • Open Access

    Head and Neck Cancers on CT: Preliminary Study of Treatment Response Assessment Based on Computerized Volume Analysis

    by Lubomir Hadjiiski, Suresh K. Mukherji, Mohannad Ibrahim, Berkman Sahiner, Sachin K. Gujar, Jeffrey Moyer, Heang-Ping Chan

    OBJECTIVE. The objective of our study was to investigate the feasibility of computerized segmentation of lesions on head and neck CT scans and evaluate its potential for estimating changes in tumor volume in response to treatment of head and neck cancers. MATERIALS AND METHODS. Twenty-six CT scans were retrospectively collected from the files of 13 patients with 35 head and neck lesions. The CT scans were obtained from an examination performed before treatment (pretreatment scan) and an examination performed after one cycle of chemotherapy (posttreatment scan). Thirteen lesions were primary site cancers and 22 were metastatic lymph nodes. An experienced radiologist (radiologist 1) marked the 35 lesions and outlined each lesion's 2D contour on the best slice on both the pre- and posttreatment scans. Full 3D contours were also manually extracted for the 13 primary tumors. Another experienced radiologist (radiologist 2) verified and modified, if necessary, all manually drawn 2D and 3D contours. An in-house-developed computerized system performed 3D segmentation based on a level set model. RESULTS. The computer-estimated change in tumor volume and percentage change in tumor volume between the pre- and posttreatment scans achieved a high correlation (intraclass correlation coefficient [ICC] = 0.98 and 0.98, respectively) with the estimates from manual segmentation for the 13 primary tumors. The average error in estimating the percentage change in tumor volume by automatic segmentation relative to the radiologists' average error was –1.5% ± 5.4% (SD). For the 35 lesions, the ICC between the automatic and manual estimates of change in pre- to posttreatment tumor area was 0.93 and of percentage change in pre- to posttreatment tumor area was 0.85. The average error in estimating the percentage change in tumor area by automatic segmentation was –3.2% ± 15.3%. CONCLUSION. Preliminary results indicate that this computerized segmentation system can reliably estimate changes in tumor size on CT scans relative to radiologists' manual segmentation. This information can be used to calculate changes in tumor size on pre- and posttreatment scans to assess response to treatment.