Marcin Stański
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marcin Stański has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Katarzyna Katulska
Department of General Radiology and Neuroradiology, Poznań University of Medical Sciences, Przybyszewskiego 49, Poznan 60-355, Poland
3 shared publications- Katarzyna Katulska
Department of General Radiology and Neuroradiology, Poznan University of Medical Sciences, Poznan, Poland
3 shared publications Jacek Wątorek
Department of General Radiology and Neuroradiology, Poznań University of Medical Sciences, Przybyszewskiego 49, Poznan 60-355, Poland
2 shared publicationsJakub Moskal
Department of Neurosurgery, Poznań University of Medical Sciences, Przybyszewskiego 49, Poznan 60-355, Poland
2 shared publicationsMikołaj Goralewski
Department of Neurosurgery, Poznań University of Medical Sciences, Przybyszewskiego 49, Poznan 60-355, Poland
2 shared publications- Natalia Krystyna Majewska
Department of General Radiology and Neuroradiology, Poznan University of Medical Sciences, Poznan, Poland
2 shared publications
Latest Publications
- 20 May 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 433, 110808
Surface-based morphometry in lesioned brains after virtual brain grafting: CAT12 versus FreeSurfer in low-grade glioma
- 20 May 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 433, 110808
Surface-based morphometry in lesioned brains after virtual brain grafting: CAT12 versus FreeSurfer in low-grade glioma
- 16 March 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1343-1351
Contra-lesional hippocampus in low grade glioma patients with no hippocampal infiltration - a study of structural remodelling
- 16 March 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1343-1351
Contra-lesional hippocampus in low grade glioma patients with no hippocampal infiltration - a study of structural remodelling
- Open Access
- 27 May 2025
- Published by Elsevier in European Journal of Radiology Open
- Vol. 14, 100660
Brain MRI morphometry for structural alterations in patients with glioma – A systematic review
- 27 May 2025
- Published by Elsevier in European Journal of Radiology Open
- Vol. 14, 100660
Open AccessBrain MRI morphometry for structural alterations in patients with glioma – A systematic review
- Open Access
- 11 June 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (12) , 1223
Dual-Energy and Photon-Counting Computed Tomography in Vascular Applications—Technical Background and Post-Processing Techniques
The field of computed tomography (CT), which is a basic diagnostic tool in clinical practice, has recently undergone rapid technological advances. These include the evolution of dual-energy CT (DECT) and development of photon-counting computed tomography (PCCT). DECT enables the acquisition of CT images at two different energy spectra, which allows for the differentiation of certain materials, mainly calcium and iodine. PCCT is a recent technology that enables a scanner to quantify the energy of each photon gathered by the detector. This method gives the possibility to decrease the radiation dose and increase the spatial and temporal resolutions of scans. Both of these techniques have found a wide range of applications in radiology, including vascular studies. In this narrative review, the authors present the principles of DECT and PCCT, outline their advantages and drawbacks, and briefly discuss the application of these methods in vascular radiology.
- 11 June 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (12) , 1223
Open AccessDual-Energy and Photon-Counting Computed Tomography in Vascular Applications—Technical Background and Post-Processing Techniques
The field of computed tomography (CT), which is a basic diagnostic tool in clinical practice, has recently undergone rapid technological advances. These include the evolution of dual-energy CT (DECT) and development of photon-counting computed tomography (PCCT). DECT enables the acquisition of CT images at two different energy spectra, which allows for the differentiation of certain materials, mainly calcium and iodine. PCCT is a recent technology that enables a scanner to quantify the energy of each photon gathered by the detector. This method gives the possibility to decrease the radiation dose and increase the spatial and temporal resolutions of scans. Both of these techniques have found a wide range of applications in radiology, including vascular studies. In this narrative review, the authors present the principles of DECT and PCCT, outline their advantages and drawbacks, and briefly discuss the application of these methods in vascular radiology.
- Open Access
- 23 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 101
The Usefulness of MRI Dynamic Flow Sequences in Differentiating High- and Low-Flow Vascular Malformations
Peripheral arteriovenous malformations (PVMs) can be classified into high-flow malformations (HFVMs) and low-flow malformations (LFVMs). Adequate distinguishment is crucial for therapeutic decision and can be done using dynamic contrast-enhanced MRI (DCE-MRI). The main aim of this retrospective study was to determine the diagnostic value of quantitative DCE-MRI ratios for differentiation between HFVM and LFVM, their optimal cut-off points, and predictive values. DCE-MRI time-resolved angiography with stochastic trajectory (TWIST) examinations of 90 patients with PVMs were included [28 HFVM (31%), 62 LFVM (69%)]. The measurements of artery-lesion time, maximum lesion enhancement, slope of the enhancement curve, and maximum percentage increase of signal intensity (SI) were obtained. The optimal cut-offs for HFVMs calculated using the Youden index were: for slope of enhancement curve < 8.7 s (sensitivity of 86%, specificity of 89%), artery-lesion time ≤ 5.6 s (sensitivity of 89%, specificity of 77%), time to maximum enhancement ≤ 30 s (sensitivity of 94%, specificity of 100%), and maximum percentage enhancement of the lesion > 662% (sensitivity of 68%, specificity of 69%). To summarize, DCE-MRI is very valuable for differentiation between HFVM and LFVM, especially if quantitative measurements are done.
- 23 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 101
Open AccessThe Usefulness of MRI Dynamic Flow Sequences in Differentiating High- and Low-Flow Vascular Malformations
Peripheral arteriovenous malformations (PVMs) can be classified into high-flow malformations (HFVMs) and low-flow malformations (LFVMs). Adequate distinguishment is crucial for therapeutic decision and can be done using dynamic contrast-enhanced MRI (DCE-MRI). The main aim of this retrospective study was to determine the diagnostic value of quantitative DCE-MRI ratios for differentiation between HFVM and LFVM, their optimal cut-off points, and predictive values. DCE-MRI time-resolved angiography with stochastic trajectory (TWIST) examinations of 90 patients with PVMs were included [28 HFVM (31%), 62 LFVM (69%)]. The measurements of artery-lesion time, maximum lesion enhancement, slope of the enhancement curve, and maximum percentage increase of signal intensity (SI) were obtained. The optimal cut-offs for HFVMs calculated using the Youden index were: for slope of enhancement curve < 8.7 s (sensitivity of 86%, specificity of 89%), artery-lesion time ≤ 5.6 s (sensitivity of 89%, specificity of 77%), time to maximum enhancement ≤ 30 s (sensitivity of 94%, specificity of 100%), and maximum percentage enhancement of the lesion > 662% (sensitivity of 68%, specificity of 69%). To summarize, DCE-MRI is very valuable for differentiation between HFVM and LFVM, especially if quantitative measurements are done.
- Open Access
- 31 December 2021
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 86 (1) , 692-699
COVID-19 pandemic in flu season. Chest computed tomography – what we know so far
Chest computed tomography (CT) is proven to have high sensitivity in COVID-19 diagnosis. It is available in most emergency wards, and in contrast to polymerase chain reaction (PCR) it can be obtained in several minutes. However, its imaging features change during the course of the disease and...
- 31 December 2021
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 86 (1) , 692-699
Open AccessCOVID-19 pandemic in flu season. Chest computed tomography – what we know so far
Chest computed tomography (CT) is proven to have high sensitivity in COVID-19 diagnosis. It is available in most emergency wards, and in contrast to polymerase chain reaction (PCR) it can be obtained in several minutes. However, its imaging features change during the course of the disease and...