Alexander John Headley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexander John Headley has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Michael Alexander Meehan
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
2 shared publications - Ala' E. Qatramez
Department of Mechanical Engineering, University of Memphis , Memphis, TN 38152
1 shared publication - Ala' Qatramez
University of Memphis
1 shared publication Albuquerque Sandia National Laboratories (Snl-Nm)
1 shared publication- Andrew Kurzawski
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
1 shared publication - Andrew Kurzawski
Fire Science and Technology Department, Sandia National Laboratories , Albuquerque, NM 87185
1 shared publication
Latest Publications
- 6 February 2025
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 147 (5) , 1-20
Predictions of Cell-to-Cell Propagation and Vent Gas Production in the Thermal Runaway of Lithium-Ion Battery Stacks
This work presents the thermal runaway propagation model LIM1TR (Lithium-ion Modeling with 1-D Thermal Runaway) as an efficient tool to predict different cell-to-cell thermal runaway propagation scenarios. We explored the vent gas volume production and reaction duration highlighting the relationship between these parameters and thermal runaway propagation due to convection by the vented gases. Two metrics based on gas production rate and heating rate are utilized as good indicators of the start and end of thermal runaway. LIM1TR results are compared with and validated by experiments from the literature for single-cell and multicell array experiments of 5 Ah and 10 Ah cells. By accounting for intraparticle diffusion of reacting species in the electrodes, we were able to capture the general dynamics of thermal runaway propagation and estimate acceptable reaction durations compared with the experimental values. Simulation results further demonstrated that varying heating modes lead to distinct reaction durations, consistent with experimental observations. Vent gas volume predictions indicate the need to consider both full and partial oxidation of the electrolyte. The outcomes of this work are building blocks for further investigations of module-to-module propagation by vented gases through convective heat transfer.
- 6 February 2025
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 147 (5) , 1-20
Predictions of Cell-to-Cell Propagation and Vent Gas Production in the Thermal Runaway of Lithium-Ion Battery Stacks
This work presents the thermal runaway propagation model LIM1TR (Lithium-ion Modeling with 1-D Thermal Runaway) as an efficient tool to predict different cell-to-cell thermal runaway propagation scenarios. We explored the vent gas volume production and reaction duration highlighting the relationship between these parameters and thermal runaway propagation due to convection by the vented gases. Two metrics based on gas production rate and heating rate are utilized as good indicators of the start and end of thermal runaway. LIM1TR results are compared with and validated by experiments from the literature for single-cell and multicell array experiments of 5 Ah and 10 Ah cells. By accounting for intraparticle diffusion of reacting species in the electrodes, we were able to capture the general dynamics of thermal runaway propagation and estimate acceptable reaction durations compared with the experimental values. Simulation results further demonstrated that varying heating modes lead to distinct reaction durations, consistent with experimental observations. Vent gas volume predictions indicate the need to consider both full and partial oxidation of the electrolyte. The outcomes of this work are building blocks for further investigations of module-to-module propagation by vented gases through convective heat transfer.
- Open Access
- 1 August 2024
- Published by Office of Scientific and Technical Information (OSTI)
Safety Hazards Associated with Li-ion Batteries Thermal Runaway Vent Gas due to Heat Transfer
Motivations and Objectives • Li-ion batteries can fail catastrophically at high temperatures in a process called thermal runaway. • Serious safety issues are associated with thermal runaway propagation. • Li-ion batteries vent high-temperature, combustible gases during thermal runaway. • Objective: Estimate heat flux from impinging vent gases for different module geometries and venting speeds.
- 1 August 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessSafety Hazards Associated with Li-ion Batteries Thermal Runaway Vent Gas due to Heat Transfer
Motivations and Objectives • Li-ion batteries can fail catastrophically at high temperatures in a process called thermal runaway. • Serious safety issues are associated with thermal runaway propagation. • Li-ion batteries vent high-temperature, combustible gases during thermal runaway. • Objective: Estimate heat flux from impinging vent gases for different module geometries and venting speeds.
- 24 January 2023
- Published by ASME International in ASME Journal of Engineering for Sustainable Buildings and Cities
- Vol. 4 (1) , 1-56
Optimization of Energy Storage Systems and Demand Side Management to Maximize Water Utility Savings: A Hawaii Case Study
Energy conservation is a concern in many industries, and consequently, facility operators are turning to various efficiency measures or alternative power sources to reduce electricity costs. With the expanding use of intermittent resources, energy storage systems (ESSs) and demand side management (DSM) options are also gaining interest to maximize potential energy savings. Here, we study the potential of ESSs versus DSM for water utilities through a case study of the National Energy Laboratory of the Hawaii Authority (NELHA). NELHA is a multizone water utility in which most of its electricity usage is dedicated to pumping water. In this study, the optimization of the overall electricity charges for NELHA, using both ESSs or DSM via pump load shifting and optimization of pump house output is investigated. An optimization algorithm is created to determine the optimal size of the batteries for installation considering the water demand and energy costs in each zone. An extended approach of considering the characteristics of individual pumps on each pump house in the optimization model is applied to provide insight into the proper optimization framework for dispatching pumps depending on the current zonal load, given pump efficiencies, and maximum flowrates from each pump. The outcome from mathematical models using general quadratic pump efficiency functions and a simplified linear version of pump efficiency is compared to determine the significance of this difference in modeling methodology in estimations and evaluations. Additionally, the effect of increasing solar power on electricity purchased is analyzed. This work will help to establish the role of ESS and DSM in energy savings for water utility industry as well as show what methods should be used for evaluation of the potential of ESS and DSM interventions.
- 24 January 2023
- Published by ASME International in ASME Journal of Engineering for Sustainable Buildings and Cities
- Vol. 4 (1) , 1-56
Optimization of Energy Storage Systems and Demand Side Management to Maximize Water Utility Savings: A Hawaii Case Study
Energy conservation is a concern in many industries, and consequently, facility operators are turning to various efficiency measures or alternative power sources to reduce electricity costs. With the expanding use of intermittent resources, energy storage systems (ESSs) and demand side management (DSM) options are also gaining interest to maximize potential energy savings. Here, we study the potential of ESSs versus DSM for water utilities through a case study of the National Energy Laboratory of the Hawaii Authority (NELHA). NELHA is a multizone water utility in which most of its electricity usage is dedicated to pumping water. In this study, the optimization of the overall electricity charges for NELHA, using both ESSs or DSM via pump load shifting and optimization of pump house output is investigated. An optimization algorithm is created to determine the optimal size of the batteries for installation considering the water demand and energy costs in each zone. An extended approach of considering the characteristics of individual pumps on each pump house in the optimization model is applied to provide insight into the proper optimization framework for dispatching pumps depending on the current zonal load, given pump efficiencies, and maximum flowrates from each pump. The outcome from mathematical models using general quadratic pump efficiency functions and a simplified linear version of pump efficiency is compared to determine the significance of this difference in modeling methodology in estimations and evaluations. Additionally, the effect of increasing solar power on electricity purchased is analyzed. This work will help to establish the role of ESS and DSM in energy savings for water utility industry as well as show what methods should be used for evaluation of the potential of ESS and DSM interventions.