Ruitong Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruitong Yang has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Dong Li
6 shared publications- Dong Li
School of Architecture and Civil Engineering, Northeast Petroleum University, Daqing 163318, China
5 shared publications - Müslüm Arıcı
Mechanical Engineering Department, Engineering Faculty, Kocaeli University, Kocaeli 41001, Turkey
5 shared publications Chengjun Zhang
3 shared publicationsSamanta López Salazar
3 shared publications- Xinpeng Yang
School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
3 shared publications
Latest Publications
- Open Access
- 22 February 2026
- Published by Union of Mechanical and Electrotechnical Engineers and Technicians of Serbia (SMEITS)
- Vol. 56 (1) , 305-316
Numerical study on latent heat storage and energy saving potential of PCM walls
The goal of this study is to numerically investigate the effects of different phase change material (PCM) types, thicknesses, and placement positions within the external wall structure on latent heat storage and, consequently, on heating and cooling energy savings in residential buildings. Three different PCM types were analyzed and compared with a phase stabilized material (PSM), which possesses identical thermal properties but does not undergo phase transition, to isolate and quantify the specific contribution of latent heat. In addition, comparisons with a conventional wall without PCM were carried out, enabling the evaluation of both latent heat contribution and the overall effect on thermal inertia. The analyses were conducted under the climatic condition of Istanbul, Turkey, which is classified as a Csa (hot-summer Mediterranean) climate according to the Koppen-Geiger classification. This study addresses not only annual and monthly analyses but also daily and hourly assessments, enabling a deeper understanding of the transient thermal behavior and thermal inertia of PCMs. The findings underline the importance of optimizing PCM type, thickness, and placement in building envelope design to maximize energy efficiency. The results reveal that placing PCM closer to the inner surface provides the most effective latent heat utilization and the highest energy savings, with 30mm RT18 reducing annual heating and cooling energy demand by up to 4% compared to the base case. While increasing PCM thickness from 1 mm to 30 mm generally reduced total annual energy demand (by 2.5% on average), the cooling load response was not consistent. For instance, when RT18 was placed near the outer surface, a 1 mm layer has same cooling demand as base case while an 18 mm layer increased it by 1% due to delayed heat release during peak cooling periods. For some cases, such as when RT21 and RT25 PCMs were positioned near the outer surface, the latent heat effect was negligible, resulting in nearly the same total annual load as the reference case. Moreover, when PCMs were placed closer to the inner surface, the latent heat contribution remained consistently positive across all thicknesses.
- 22 February 2026
- Published by Union of Mechanical and Electrotechnical Engineers and Technicians of Serbia (SMEITS)
- Vol. 56 (1) , 305-316
Open AccessNumerical study on latent heat storage and energy saving potential of PCM walls
The goal of this study is to numerically investigate the effects of different phase change material (PCM) types, thicknesses, and placement positions within the external wall structure on latent heat storage and, consequently, on heating and cooling energy savings in residential buildings. Three different PCM types were analyzed and compared with a phase stabilized material (PSM), which possesses identical thermal properties but does not undergo phase transition, to isolate and quantify the specific contribution of latent heat. In addition, comparisons with a conventional wall without PCM were carried out, enabling the evaluation of both latent heat contribution and the overall effect on thermal inertia. The analyses were conducted under the climatic condition of Istanbul, Turkey, which is classified as a Csa (hot-summer Mediterranean) climate according to the Koppen-Geiger classification. This study addresses not only annual and monthly analyses but also daily and hourly assessments, enabling a deeper understanding of the transient thermal behavior and thermal inertia of PCMs. The findings underline the importance of optimizing PCM type, thickness, and placement in building envelope design to maximize energy efficiency. The results reveal that placing PCM closer to the inner surface provides the most effective latent heat utilization and the highest energy savings, with 30mm RT18 reducing annual heating and cooling energy demand by up to 4% compared to the base case. While increasing PCM thickness from 1 mm to 30 mm generally reduced total annual energy demand (by 2.5% on average), the cooling load response was not consistent. For instance, when RT18 was placed near the outer surface, a 1 mm layer has same cooling demand as base case while an 18 mm layer increased it by 1% due to delayed heat release during peak cooling periods. For some cases, such as when RT21 and RT25 PCMs were positioned near the outer surface, the latent heat effect was negligible, resulting in nearly the same total annual load as the reference case. Moreover, when PCMs were placed closer to the inner surface, the latent heat contribution remained consistently positive across all thicknesses.
- 1 January 2025
- Published by Springer Nature
- p. 396-405
Optimization of Architectural Design to Improve Thermal Performance in Standard Housing in Daqing, China
- 1 January 2025
- Published by Springer Nature
- p. 396-405
Optimization of Architectural Design to Improve Thermal Performance in Standard Housing in Daqing, China
- 26 September 2024
- Published by Elsevier in Energy and Buildings
- Vol. 324
Thermal performance of multifunctional louver window integrated phase change material and spherical louver
- 26 September 2024
- Published by Elsevier in Energy and Buildings
- Vol. 324
Thermal performance of multifunctional louver window integrated phase change material and spherical louver
- 29 July 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 442
Thermal performance of glazing envelopes embedded with nano-enhanced paraffin: a comparative study
- 29 July 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 442
Thermal performance of glazing envelopes embedded with nano-enhanced paraffin: a comparative study
- Open Access
Economic Optimization of Thermal Insulation Thickness for Insulated and Electrically Traced Pipelines in Drilling Applications
This study presents an economic optimization model for determining the optimal insulation thickness for both thermal insulation and electric tracing pipelines. Using Life-Cycle Cost (LCC) analysis, optimization research was conducted under various working conditions to identify the most cost-effective insulation thickness. Factors such as pipe diameter, operational duration, drilling fluid temperature, and heat cost were analyzed to assess their impact on the economic thickness of the insulation layer, specifically within the unique environment of drilling sites. The results provide the economic thickness and total cost for both insulated and electrically traced pipelines under different scenarios. For instance, for a DN100 pipe with rock wool insulation operating for 3600 h, the economic thickness of the electrically traced pipe insulation was determined to be 5.18 cm greater per unit length compared to the non-electrically traced pipe, resulting in an additional cost of 19.36 CNY/m. These findings offer valuable insights for optimizing pipeline insulation in drilling applications.
Open AccessEconomic Optimization of Thermal Insulation Thickness for Insulated and Electrically Traced Pipelines in Drilling Applications
This study presents an economic optimization model for determining the optimal insulation thickness for both thermal insulation and electric tracing pipelines. Using Life-Cycle Cost (LCC) analysis, optimization research was conducted under various working conditions to identify the most cost-effective insulation thickness. Factors such as pipe diameter, operational duration, drilling fluid temperature, and heat cost were analyzed to assess their impact on the economic thickness of the insulation layer, specifically within the unique environment of drilling sites. The results provide the economic thickness and total cost for both insulated and electrically traced pipelines under different scenarios. For instance, for a DN100 pipe with rock wool insulation operating for 3600 h, the economic thickness of the electrically traced pipe insulation was determined to be 5.18 cm greater per unit length compared to the non-electrically traced pipe, resulting in an additional cost of 19.36 CNY/m. These findings offer valuable insights for optimizing pipeline insulation in drilling applications.
- 27 June 2024
- Published by Elsevier in Energy and Buildings
- Vol. 318
Optimizing the indoor thermal environment and daylight performance of buildings with PCM glazing
- 27 June 2024
- Published by Elsevier in Energy and Buildings
- Vol. 318
Optimizing the indoor thermal environment and daylight performance of buildings with PCM glazing
- Open Access
Advancing Sustainable Energy Solutions: Innovations in Clean Energy Applications and Conventional Energy Efficiency Upgrade
The transition to clean and low-carbon energy sources is an imperative driven by the urgent challenges of climate change, energy security, and environmental sustainability
Open AccessAdvancing Sustainable Energy Solutions: Innovations in Clean Energy Applications and Conventional Energy Efficiency Upgrade
The transition to clean and low-carbon energy sources is an imperative driven by the urgent challenges of climate change, energy security, and environmental sustainability