Monica M. S. Matsumoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Monica M. S. Matsumoto has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Marcus Victor
Aeronautics Institute of Technology
4 shared publications - Arthur S. Ribeiro
Electronics Engineering Division, Aeronautics Institute of Technology, Sao Paulo, Brazil
2 shared publications - Marcos Ricardo Omena Albuquerque Maximo
Autonomous Computational Systems Lab (LAB-SCA), Computer Science Division, Aeronautics Institute of Technology, São José dos Campos, Brazil
2 shared publications - Alice Nova
Mass General Brigham and Harvard Medical School
1 shared publication - Jean Phelipe de Oliveira Lima
Department of Aeronautical Infrastructure Engineering, Aeronautics Institute of Technology (ITA), São José dos Campos 12228-900, Brazil
1 shared publication - Maurizio Cereda
Department of Anesthesiology, Mass General Brigham, Boston, MA
1 shared publication
Latest Publications
- 13 June 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (4) , 045013
Supervised and unsupervised learning for lung perfusion data segmentation in electrical impedance tomography
Objective: Effective lung gas exchange relies on the balance between alveolar ventilation and perfusion, which can be disrupted in mechanically ventilated patients. Lung perfusion assessment using electrical impedance tomography (EIT) typically involves a sudden injection of a hypertonic saline solution. The large field of view provided by EIT often results in ambivalent behavior of many voxel waveforms following an indicator injection, where some exhibit indicator kinetics solely through the lungs (pulmonary), while others show passage through both the heart and lungs (hybrid). Consequently, a segmentation algorithm is essential for accurate perfusion evaluation. Approach: Sixteen pigs (29–35 kg) were mechanically ventilated and received a 10 ml bolus of 7.5% NaCl solution to assess lung perfusion during a healthy stage and, later, in an injured stage after receiving 3.5 ml kg−1 of HCl to induce acute lung injury. Supervised (Bagged Trees, Neural Networks, and Support Vector Machine) and unsupervised (K-means, Hierarchical, and Principal Component Analysis) learning methods were employed using 115 saline injections comprising voxel waveforms to label voxels as either hybrid or pulmonary. All segmentation methods were compared to a ground-truth mask manually drawn. A training dataset (81 injections) was used to train and cross-validate (five-fold) the supervised methods using previously extracted features. The test dataset (34 injections) was used to test both supervised and unsupervised learning algorithms. Main Results: A Principal Component Analysis (unsupervised learning) method exhibited the best overall performance, achieving 83% sensitivity, 92% specificity, 89% accuracy, and 84% dice similarity coefficient. No significant difference in performance was observed between healthy and injured subsets. Unsupervised methods consistently yielded more physiologically plausible and less scattered regions of interest. Significance: Accurate voxel labeling is crucial for lung perfusion assessment, as it enables discrimination of the indicator passage through the heart and lungs, thereby improving the estimation of regional pulmonary blood flow.
- 13 June 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (4) , 045013
Supervised and unsupervised learning for lung perfusion data segmentation in electrical impedance tomography
Objective: Effective lung gas exchange relies on the balance between alveolar ventilation and perfusion, which can be disrupted in mechanically ventilated patients. Lung perfusion assessment using electrical impedance tomography (EIT) typically involves a sudden injection of a hypertonic saline solution. The large field of view provided by EIT often results in ambivalent behavior of many voxel waveforms following an indicator injection, where some exhibit indicator kinetics solely through the lungs (pulmonary), while others show passage through both the heart and lungs (hybrid). Consequently, a segmentation algorithm is essential for accurate perfusion evaluation. Approach: Sixteen pigs (29–35 kg) were mechanically ventilated and received a 10 ml bolus of 7.5% NaCl solution to assess lung perfusion during a healthy stage and, later, in an injured stage after receiving 3.5 ml kg−1 of HCl to induce acute lung injury. Supervised (Bagged Trees, Neural Networks, and Support Vector Machine) and unsupervised (K-means, Hierarchical, and Principal Component Analysis) learning methods were employed using 115 saline injections comprising voxel waveforms to label voxels as either hybrid or pulmonary. All segmentation methods were compared to a ground-truth mask manually drawn. A training dataset (81 injections) was used to train and cross-validate (five-fold) the supervised methods using previously extracted features. The test dataset (34 injections) was used to test both supervised and unsupervised learning algorithms. Main Results: A Principal Component Analysis (unsupervised learning) method exhibited the best overall performance, achieving 83% sensitivity, 92% specificity, 89% accuracy, and 84% dice similarity coefficient. No significant difference in performance was observed between healthy and injured subsets. Unsupervised methods consistently yielded more physiologically plausible and less scattered regions of interest. Significance: Accurate voxel labeling is crucial for lung perfusion assessment, as it enables discrimination of the indicator passage through the heart and lungs, thereby improving the estimation of regional pulmonary blood flow.
- 4 January 2024
- Published by Springer Nature
- p. 313-323
Evaluation of Explainable AI Methods in CNN Classifiers of COVID-19 CT Images
- 4 January 2024
- Published by Springer Nature
- p. 313-323
Evaluation of Explainable AI Methods in CNN Classifiers of COVID-19 CT Images
- 4 January 2024
- Published by Springer Nature
- p. 167-176
Unsupervised Clustering Methods for Lung Perfusion Data Segmentation in Electrical Impedance Tomography
- 4 January 2024
- Published by Springer Nature
- p. 167-176
Unsupervised Clustering Methods for Lung Perfusion Data Segmentation in Electrical Impedance Tomography
- 22 December 2022
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 39 (1) , e3668
Mixed‐integer quadratic programming approach for noninvasive estimation of respiratory effort profile during pressure support ventilation
Information about respiratory mechanics such as resistance, elastance, and muscular pressure is important to mitigate ventilator‐induced lung injury. Particularly during pressure support ventilation, the available options to quantify breathing effort and calculate respiratory system mechanics are often invasive or complex. We herein propose a robust and flexible estimation of respiratory effort better than current methods. We developed a method for non‐invasively estimating breathing effort using only flow and pressure signals. Mixed‐integer quadratic programming (MIQP) was employed, and the binary variables were the switching moments of the respiratory effort waveform. Mathematical constraints, based on ventilation physiology, were set for some variables to restrict feasible solutions. Simulated and patient data were used to verify our method, and the results were compared to an established estimation methodology. Our algorithm successfully estimated the respiratory effort, resistance, and elastance of the respiratory system, resulting in more robust performance and faster solver times than a previously proposed algorithm that used quadratic programming (QP) techniques. In a numerical simulation benchmark, the worst‐case errors for resistance and elastance were 25% and 23% for QP versus <0.1% and <0.1% for MIQP, whose solver times were 4.7 s and 0.5 s, respectively. This approach can estimate several breathing effort profiles and identify the respiratory system's mechanical properties in invasively ventilated critically ill patients.
- 22 December 2022
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 39 (1) , e3668
Mixed‐integer quadratic programming approach for noninvasive estimation of respiratory effort profile during pressure support ventilation
Information about respiratory mechanics such as resistance, elastance, and muscular pressure is important to mitigate ventilator‐induced lung injury. Particularly during pressure support ventilation, the available options to quantify breathing effort and calculate respiratory system mechanics are often invasive or complex. We herein propose a robust and flexible estimation of respiratory effort better than current methods. We developed a method for non‐invasively estimating breathing effort using only flow and pressure signals. Mixed‐integer quadratic programming (MIQP) was employed, and the binary variables were the switching moments of the respiratory effort waveform. Mathematical constraints, based on ventilation physiology, were set for some variables to restrict feasible solutions. Simulated and patient data were used to verify our method, and the results were compared to an established estimation methodology. Our algorithm successfully estimated the respiratory effort, resistance, and elastance of the respiratory system, resulting in more robust performance and faster solver times than a previously proposed algorithm that used quadratic programming (QP) techniques. In a numerical simulation benchmark, the worst‐case errors for resistance and elastance were 25% and 23% for QP versus <0.1% and <0.1% for MIQP, whose solver times were 4.7 s and 0.5 s, respectively. This approach can estimate several breathing effort profiles and identify the respiratory system's mechanical properties in invasively ventilated critically ill patients.