Tianyu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tianyu Zhang has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Jinpeng Liao
Healthcare Engineering, School of Physics and Engineering Technology, University of York York UK
8 shared publications - Chunhui Li
Centre for Medical Engineering and Technology (CMET), School of Science and Engineering, University of Dundee, Dundee DD1 4HN, UK
7 shared publications Zhihong Huang
Healthcare Engineering, School of Physics and Engineering Technology, University of York, UK
4 shared publications- Zhihong Huang
School of Physics and Engineering Technology, University of York, York, U.K.
4 shared publications - Yilong Zhang
School of Science and Engineering University of Dundee Dundee UK
3 shared publications Chunhui Li
University of Dundee
2 shared publications
Latest Publications
- 13 August 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (8) , e70337
In Vivo Monitoring of Facial Acne Development by Using Multimodal Functional OCT
Acne is a common inflammatory skin condition and frequently leads to long‐term adverse clinical outcomes including scarring and pigmentation, negatively impacting Health Related Quality of Life (HRQoL). Monitoring of acne progression can improve understanding of lesion evolution, support evaluation of treatment response and provide potential biomarkers for future investigation of acne sequelae. This study presents a multi‐functional optical coherence tomography (OCT) protocol integrating structural imaging, OCT‐based angiography (OCTA), and optical coherence elastography (OCE) for longitudinal in vivo monitoring of acne. Thirteen lesions were evaluated across eight time points over 18 days. Quantitative parameters, including Young's modulus and vascular metrics, captured biomechanical and microvascular changes during acne evolution. The system enables continuous multimodal assessment, showing that stiffness and vascular alterations reflect lesion progression. This pilot longitudinal study establishes a quantitative foundation for dermatological research and suggests that multimodal OCT monitoring may provide biomarkers for assessing lesion progression and long‐term clinical outcomes.
- 13 August 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (8) , e70337
In Vivo Monitoring of Facial Acne Development by Using Multimodal Functional OCT
Acne is a common inflammatory skin condition and frequently leads to long‐term adverse clinical outcomes including scarring and pigmentation, negatively impacting Health Related Quality of Life (HRQoL). Monitoring of acne progression can improve understanding of lesion evolution, support evaluation of treatment response and provide potential biomarkers for future investigation of acne sequelae. This study presents a multi‐functional optical coherence tomography (OCT) protocol integrating structural imaging, OCT‐based angiography (OCTA), and optical coherence elastography (OCE) for longitudinal in vivo monitoring of acne. Thirteen lesions were evaluated across eight time points over 18 days. Quantitative parameters, including Young's modulus and vascular metrics, captured biomechanical and microvascular changes during acne evolution. The system enables continuous multimodal assessment, showing that stiffness and vascular alterations reflect lesion progression. This pilot longitudinal study establishes a quantitative foundation for dermatological research and suggests that multimodal OCT monitoring may provide biomarkers for assessing lesion progression and long‐term clinical outcomes.
- Open Access
- 26 February 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (3) , 1197-1215
Semi-supervised assisted multi-task learning for oral optical coherence tomography image segmentation and denoising
Optical coherence tomography (OCT) is promising to become an essential imaging tool for non-invasive oral mucosal tissue assessment, but it faces challenges like speckle noise and motion artifacts. In addition, it is difficult to distinguish different layers of oral mucosal tissues from gray level OCT images due to the similarity of optical properties between different layers. We introduce the Efficient Segmentation-Denoising Model (ESDM), a multi-task deep learning framework designed to enhance OCT imaging by reducing scan time from ∼8s to ∼2s and improving oral epithelium layer segmentation. ESDM integrates the local feature extraction capabilities of the convolution layer and the long-term information processing advantages of the transformer, achieving better denoising and segmentation performance compared to existing models. Our evaluation shows that ESDM outperforms state-of-the-art models with a PSNR of 26.272, SSIM of 0.737, mDice of 0.972, and mIoU of 0.948. Ablation studies confirm the effectiveness of our design, such as the feature fusion methods, which enhance performance with minimal model complexity increase. ESDM also presents high accuracy in quantifying oral epithelium thickness, achieving mean absolute errors as low as 5 µm compared to manual measurements. This research shows that ESDM can notably improve OCT imaging and reduce the cost of accurate oral epithermal segmentation, improving diagnostic capabilities in clinical settings.
- 26 February 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (3) , 1197-1215
Open AccessSemi-supervised assisted multi-task learning for oral optical coherence tomography image segmentation and denoising
Optical coherence tomography (OCT) is promising to become an essential imaging tool for non-invasive oral mucosal tissue assessment, but it faces challenges like speckle noise and motion artifacts. In addition, it is difficult to distinguish different layers of oral mucosal tissues from gray level OCT images due to the similarity of optical properties between different layers. We introduce the Efficient Segmentation-Denoising Model (ESDM), a multi-task deep learning framework designed to enhance OCT imaging by reducing scan time from ∼8s to ∼2s and improving oral epithelium layer segmentation. ESDM integrates the local feature extraction capabilities of the convolution layer and the long-term information processing advantages of the transformer, achieving better denoising and segmentation performance compared to existing models. Our evaluation shows that ESDM outperforms state-of-the-art models with a PSNR of 26.272, SSIM of 0.737, mDice of 0.972, and mIoU of 0.948. Ablation studies confirm the effectiveness of our design, such as the feature fusion methods, which enhance performance with minimal model complexity increase. ESDM also presents high accuracy in quantifying oral epithelium thickness, achieving mean absolute errors as low as 5 µm compared to manual measurements. This research shows that ESDM can notably improve OCT imaging and reduce the cost of accurate oral epithermal segmentation, improving diagnostic capabilities in clinical settings.
- 6 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 5723-5738
LS-Net: lightweight segmentation network for dermatological epidermal segmentation in optical coherence tomography imaging
Optical coherence tomography (OCT) can be an important tool for non-invasive dermatological evaluation, providing useful data on epidermal integrity for diagnosing skin diseases. Despite its benefits, OCT’s utility is limited by the challenges of accurate, fast epidermal segmentation due to the skin morphological diversity. To address this, we introduce a lightweight segmentation network (LS-Net), a novel deep learning model that combines the robust local feature extraction abilities of Convolution Neural Network and the long-term information processing capabilities of Vision Transformer. LS-Net has a depth-wise convolutional transformer for enhanced spatial contextualization and a squeeze-and-excitation block for feature recalibration, ensuring precise segmentation while maintaining computational efficiency. Our network outperforms existing methods, demonstrating high segmentation accuracy (mean Dice: 0.9624 and mean IoU: 0.9468) with significantly reduced computational demands (floating point operations: 1.131 G). We further validate LS-Net on our acquired dataset, showing its effectiveness in various skin sites (e.g., face, palm) under realistic clinical conditions. This model promises to enhance the diagnostic capabilities of OCT, making it a valuable tool for dermatological practice.
- 6 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 5723-5738
LS-Net: lightweight segmentation network for dermatological epidermal segmentation in optical coherence tomography imaging
Optical coherence tomography (OCT) can be an important tool for non-invasive dermatological evaluation, providing useful data on epidermal integrity for diagnosing skin diseases. Despite its benefits, OCT’s utility is limited by the challenges of accurate, fast epidermal segmentation due to the skin morphological diversity. To address this, we introduce a lightweight segmentation network (LS-Net), a novel deep learning model that combines the robust local feature extraction abilities of Convolution Neural Network and the long-term information processing capabilities of Vision Transformer. LS-Net has a depth-wise convolutional transformer for enhanced spatial contextualization and a squeeze-and-excitation block for feature recalibration, ensuring precise segmentation while maintaining computational efficiency. Our network outperforms existing methods, demonstrating high segmentation accuracy (mean Dice: 0.9624 and mean IoU: 0.9468) with significantly reduced computational demands (floating point operations: 1.131 G). We further validate LS-Net on our acquired dataset, showing its effectiveness in various skin sites (e.g., face, palm) under realistic clinical conditions. This model promises to enhance the diagnostic capabilities of OCT, making it a valuable tool for dermatological practice.
- Open Access
- 4 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1128
Quantitative Optimization of Handheld Probe External Pressure on Dermatological Microvasculature Using Optical Coherence Tomography-Based Angiography
Optical Coherence Tomography (OCT)-based angiography (OCTA) is a high-resolution, high-speed, and non-invasive imaging method that can provide vascular mapping of subcutaneous tissue up to approximately 2 mm. In dermatology applications of OCTA, handheld probes are always designed with a piece of transparent but solid contact window placed at the end of the probe to directly contact the skin for achieving better focusing between the light source and the tissue, reducing noise caused by minor movements. The pressure between the contact window and the skin is usually uncontrollable, and high external pressure affects the quality of microvascular imaging by compressing the vessels and obstructing the underlying blood flow. Therefore, it is necessary to determine a pressure range to ensure that the vessels can be fully imaged in high-quality images. In this paper, two pressure sensors were added to the existing handheld OCT probe, and the imaging probe was fixed to a metal stand and adjusted vertically to change the pressure between the probe and the tested skin site, a gradient of roughly 4 kPa (with 1–2 kPa error) increase was applied in each experiment, and the impact of pressure to the vessel was calculated. The experiment involved a total of five subjects, three areas of which were scanned (palm, back of the hand, and forearm). The vessel density was calculated to evaluate the impact of external pressure on angiography. In addition, PSNR was calculated to ensure that the quality of different tests was at a similar level. The angiography showed the highest density (about 10%) when the pressure between the contact window on the probe and the test area was between 3 and 5 kPa. As the pressure increased, the vascular density decreased, and the rate of decrease varied in different test areas. After fitting all the data points according to the different sites, the slope of the fitted line, i.e., the rate of decrease in density per unit value of pressure, was found to be 4.05% at the palm site, 6.93% at the back of the hand, and 4.55% at the forearm site. This experiment demonstrates that the pressure between the skin and contact window is a significant parameter that cannot be ignored. It is recommended that in future OCTA data collection processes and probe designs, the impact of pressure on the experiment be considered.
- 4 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1128
Open AccessQuantitative Optimization of Handheld Probe External Pressure on Dermatological Microvasculature Using Optical Coherence Tomography-Based Angiography
Optical Coherence Tomography (OCT)-based angiography (OCTA) is a high-resolution, high-speed, and non-invasive imaging method that can provide vascular mapping of subcutaneous tissue up to approximately 2 mm. In dermatology applications of OCTA, handheld probes are always designed with a piece of transparent but solid contact window placed at the end of the probe to directly contact the skin for achieving better focusing between the light source and the tissue, reducing noise caused by minor movements. The pressure between the contact window and the skin is usually uncontrollable, and high external pressure affects the quality of microvascular imaging by compressing the vessels and obstructing the underlying blood flow. Therefore, it is necessary to determine a pressure range to ensure that the vessels can be fully imaged in high-quality images. In this paper, two pressure sensors were added to the existing handheld OCT probe, and the imaging probe was fixed to a metal stand and adjusted vertically to change the pressure between the probe and the tested skin site, a gradient of roughly 4 kPa (with 1–2 kPa error) increase was applied in each experiment, and the impact of pressure to the vessel was calculated. The experiment involved a total of five subjects, three areas of which were scanned (palm, back of the hand, and forearm). The vessel density was calculated to evaluate the impact of external pressure on angiography. In addition, PSNR was calculated to ensure that the quality of different tests was at a similar level. The angiography showed the highest density (about 10%) when the pressure between the contact window on the probe and the test area was between 3 and 5 kPa. As the pressure increased, the vascular density decreased, and the rate of decrease varied in different test areas. After fitting all the data points according to the different sites, the slope of the fitted line, i.e., the rate of decrease in density per unit value of pressure, was found to be 4.05% at the palm site, 6.93% at the back of the hand, and 4.55% at the forearm site. This experiment demonstrates that the pressure between the skin and contact window is a significant parameter that cannot be ignored. It is recommended that in future OCTA data collection processes and probe designs, the impact of pressure on the experiment be considered.
- Open Access
- 12 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (14) , 1509
Robust Ultrafast Projection Pipeline for Structural and Angiography Imaging of Fourier-Domain Optical Coherence Tomography
The current methods to generate projections for structural and angiography imaging of Fourier-Domain optical coherence tomography (FD-OCT) are significantly slow for prediagnosis improvement, prognosis, real-time surgery guidance, treatments, and lesion boundary definition. This study introduced a robust ultrafast projection pipeline (RUPP) and aimed to develop and evaluate the efficacy of RUPP. RUPP processes raw interference signals to generate structural projections without the need for Fourier Transform. Various angiography reconstruction algorithms were utilized for efficient projections. Traditional methods were compared to RUPP using PSNR, SSIM, and processing time as evaluation metrics. The study used 22 datasets (hand skin: 9; labial mucosa: 13) from 8 volunteers, acquired with a swept-source optical coherence tomography system. RUPP significantly outperformed traditional methods in processing time, requiring only 0.040 s for structural projections, which is 27 times faster than traditional summation projections. For angiography projections, the best RUPP variation took 0.15 s, making it 7518 times faster than the windowed eigen decomposition method. However, PSNR decreased by 41–45% and SSIM saw reductions of 25–74%. RUPP demonstrated remarkable speed improvements over traditional methods, indicating its potential for real-time structural and angiography projections in FD-OCT, thereby enhancing clinical prediagnosis, prognosis, surgery guidance, and treatment efficacy.
- 12 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (14) , 1509
Open AccessRobust Ultrafast Projection Pipeline for Structural and Angiography Imaging of Fourier-Domain Optical Coherence Tomography
The current methods to generate projections for structural and angiography imaging of Fourier-Domain optical coherence tomography (FD-OCT) are significantly slow for prediagnosis improvement, prognosis, real-time surgery guidance, treatments, and lesion boundary definition. This study introduced a robust ultrafast projection pipeline (RUPP) and aimed to develop and evaluate the efficacy of RUPP. RUPP processes raw interference signals to generate structural projections without the need for Fourier Transform. Various angiography reconstruction algorithms were utilized for efficient projections. Traditional methods were compared to RUPP using PSNR, SSIM, and processing time as evaluation metrics. The study used 22 datasets (hand skin: 9; labial mucosa: 13) from 8 volunteers, acquired with a swept-source optical coherence tomography system. RUPP significantly outperformed traditional methods in processing time, requiring only 0.040 s for structural projections, which is 27 times faster than traditional summation projections. For angiography projections, the best RUPP variation took 0.15 s, making it 7518 times faster than the windowed eigen decomposition method. However, PSNR decreased by 41–45% and SSIM saw reductions of 25–74%. RUPP demonstrated remarkable speed improvements over traditional methods, indicating its potential for real-time structural and angiography projections in FD-OCT, thereby enhancing clinical prediagnosis, prognosis, surgery guidance, and treatment efficacy.
- 1 January 2024
- Published by University of Dundee
SSEN Annual Postgraduate Research Symposium 2024: Book of Abstracts
- 1 January 2024
- Published by University of Dundee
SSEN Annual Postgraduate Research Symposium 2024: Book of Abstracts
- Open Access
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1179-1190
VET: Vasculature Extraction Transformer for Single-Scan Optical Coherence Tomography Angiography
Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality for analyzing skin microvasculature, enabling non-invasive diagnosis and treatment monitoring. Traditional OCTA algorithms necessitate at least two-repeated scans to generate microvasculature images, while image quality is highly dependent on the repetitions of scans (e.g., 4-8). Nevertheless, a higher repetition count increases data acquisition time, causing patient discomfort and more unpredictable motion artifacts, which can result in potential misdiagnosis. To address these limitations, we proposed a vasculature extraction pipeline based on the novelty vasculature extraction transformer (VET) to generate OCTA images by using a single OCT scan. Distinct from the vision Transformer, VET utilizes convolutional projection to better learn the spatial relationships between image patches. This study recruited 15 healthy participants. The OCT scans were performed in five various skin sites, i.e., palm, arm, face, neck, and lip. Our results show that in comparison to OCTA images obtained by the speckle variance OCTA (peak-signal-to-noise ratio (PSNR): 16.13) and eigen-decomposition OCTA (PSNR: 17.08) using four repeated OCT scans, OCTA images extracted by the proposed pipeline exhibit a better PSNR (18.03) performance while reducing the data acquisition time by 75%. Visual comparisons show that the proposed pipeline outperformed traditional OCTA algorithms, particularly in the imaging of lip and face areas, where artifacts are commonly encountered. This study is the first to demonstrate that the VET can efficiently extract high-quality vasculature images from a single, rapid OCT scan. This capability significantly enhances diagnostic accuracy for patients and streamlines the imaging process.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1179-1190
Open AccessVET: Vasculature Extraction Transformer for Single-Scan Optical Coherence Tomography Angiography
Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality for analyzing skin microvasculature, enabling non-invasive diagnosis and treatment monitoring. Traditional OCTA algorithms necessitate at least two-repeated scans to generate microvasculature images, while image quality is highly dependent on the repetitions of scans (e.g., 4-8). Nevertheless, a higher repetition count increases data acquisition time, causing patient discomfort and more unpredictable motion artifacts, which can result in potential misdiagnosis. To address these limitations, we proposed a vasculature extraction pipeline based on the novelty vasculature extraction transformer (VET) to generate OCTA images by using a single OCT scan. Distinct from the vision Transformer, VET utilizes convolutional projection to better learn the spatial relationships between image patches. This study recruited 15 healthy participants. The OCT scans were performed in five various skin sites, i.e., palm, arm, face, neck, and lip. Our results show that in comparison to OCTA images obtained by the speckle variance OCTA (peak-signal-to-noise ratio (PSNR): 16.13) and eigen-decomposition OCTA (PSNR: 17.08) using four repeated OCT scans, OCTA images extracted by the proposed pipeline exhibit a better PSNR (18.03) performance while reducing the data acquisition time by 75%. Visual comparisons show that the proposed pipeline outperformed traditional OCTA algorithms, particularly in the imaging of lip and face areas, where artifacts are commonly encountered. This study is the first to demonstrate that the VET can efficiently extract high-quality vasculature images from a single, rapid OCT scan. This capability significantly enhances diagnostic accuracy for patients and streamlines the imaging process.
- 5 October 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (11) , 5583-5601
U-shaped fusion convolutional transformer based workflow for fast optical coherence tomography angiography generation in lips
Oral disorders, including oral cancer, pose substantial diagnostic challenges due to late-stage diagnosis, invasive biopsy procedures, and the limitations of existing non-invasive imaging techniques. Optical coherence tomography angiography (OCTA) shows potential in delivering non-invasive, real-time, high-resolution vasculature images. However, the quality of OCTA images are often compromised due to motion artifacts and noise, necessitating more robust and reliable image reconstruction approaches. To address these issues, we propose a novel model, a U-shaped fusion convolutional transformer (UFCT), for the reconstruction of high-quality, low-noise OCTA images from two-repeated OCT scans. UFCT integrates the strengths of convolutional neural networks (CNNs) and transformers, proficiently capturing both local and global image features. According to the qualitative and quantitative analysis in normal and pathological conditions, the performance of the proposed pipeline outperforms that of the traditional OCTA generation methods when only two repeated B-scans are performed. We further provide a comparative study with various CNN and transformer models and conduct ablation studies to validate the effectiveness of our proposed strategies. Based on the results, the UFCT model holds the potential to significantly enhance clinical workflow in oral medicine by facilitating early detection, reducing the need for invasive procedures, and improving overall patient outcomes.
- 5 October 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (11) , 5583-5601
U-shaped fusion convolutional transformer based workflow for fast optical coherence tomography angiography generation in lips
Oral disorders, including oral cancer, pose substantial diagnostic challenges due to late-stage diagnosis, invasive biopsy procedures, and the limitations of existing non-invasive imaging techniques. Optical coherence tomography angiography (OCTA) shows potential in delivering non-invasive, real-time, high-resolution vasculature images. However, the quality of OCTA images are often compromised due to motion artifacts and noise, necessitating more robust and reliable image reconstruction approaches. To address these issues, we propose a novel model, a U-shaped fusion convolutional transformer (UFCT), for the reconstruction of high-quality, low-noise OCTA images from two-repeated OCT scans. UFCT integrates the strengths of convolutional neural networks (CNNs) and transformers, proficiently capturing both local and global image features. According to the qualitative and quantitative analysis in normal and pathological conditions, the performance of the proposed pipeline outperforms that of the traditional OCTA generation methods when only two repeated B-scans are performed. We further provide a comparative study with various CNN and transformer models and conduct ablation studies to validate the effectiveness of our proposed strategies. Based on the results, the UFCT model holds the potential to significantly enhance clinical workflow in oral medicine by facilitating early detection, reducing the need for invasive procedures, and improving overall patient outcomes.
- 12 September 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (18) , 4857-4860
Development of an intraoral handheld optical coherence tomography-based angiography probe for multi-site oral imaging
Oral cancer, primarily oral squamous cell carcinomas (OSCC), is a major health concern worldwide. The current gold standard for the diagnosis of OSCC is biopsy and histopathological analysis, which is invasive and can place a huge financial burden on the healthcare system. Optical coherence tomography-based angiography (OCTA) is a non-invasive imaging technique that shows promise as an imaging modality to aid the diagnosis of OSCC. This Letter outlines the development of a handheld intraoral OCT probe applied to a swept-source OCT system with an angiography function for oral applications. The probe has a thin body with a diameter of 17.8 mm and a two-lens system with a working distance that is adjustable from 20.92 mm to 24.08 mm, a field of view 9 mm in diameter, an imaging depth of ∼1.7 mm, and resolutions of 39.38 µm (laterally) and 33.37 µm (axially). This probe was used to scan 14 oral sites to evaluate its ability to scan various sites in the oral cavity. This system has the potential to reduce invasive procedures and aid early OSCC diagnosis.
- 12 September 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (18) , 4857-4860
Development of an intraoral handheld optical coherence tomography-based angiography probe for multi-site oral imaging
Oral cancer, primarily oral squamous cell carcinomas (OSCC), is a major health concern worldwide. The current gold standard for the diagnosis of OSCC is biopsy and histopathological analysis, which is invasive and can place a huge financial burden on the healthcare system. Optical coherence tomography-based angiography (OCTA) is a non-invasive imaging technique that shows promise as an imaging modality to aid the diagnosis of OSCC. This Letter outlines the development of a handheld intraoral OCT probe applied to a swept-source OCT system with an angiography function for oral applications. The probe has a thin body with a diameter of 17.8 mm and a two-lens system with a working distance that is adjustable from 20.92 mm to 24.08 mm, a field of view 9 mm in diameter, an imaging depth of ∼1.7 mm, and resolutions of 39.38 µm (laterally) and 33.37 µm (axially). This probe was used to scan 14 oral sites to evaluate its ability to scan various sites in the oral cavity. This system has the potential to reduce invasive procedures and aid early OSCC diagnosis.
- Open Access
- 28 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 378
Windowed Eigen-Decomposition Algorithm for Motion Artifact Reduction in Optical Coherence Tomography-Based Angiography
Optical coherence tomography-based angiography (OCTA) has attracted attention in clinical applications as a non-invasive and high-resolution imaging modality. Motion artifacts are the most seen artifact in OCTA. Eigen-decomposition (ED) algorithms are popular choices for OCTA reconstruction, but have limitations in the reduction of motion artifacts. The OCTA data do not meet one of the requirements of ED, which is that the data should be normally distributed. To overcome this drawback, we propose an easy-to-deploy development of ED, windowed-ED (wED). wED applies a moving window to the input data, which can contrast the blood-flow signals with significantly reduced motion artifacts. To evaluate our wED algorithm, pre-acquired dorsal wound healing data in a murine model were used. The ideal window size was optimized by fitting the data distribution with the normal distribution. Lastly, the cross-sectional and en face results were compared among several OCTA reconstruction algorithms, Speckle Variance, A-scan ED (aED), B-scan ED, and wED. wED could reduce the background noise intensity by 18% and improve PSNR by 4.6%, compared to the second best-performed algorithm, aED. This study can serve as a guide for utilizing wED to reconstruct OCTA images with an optimized window size.
- 28 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 378
Open AccessWindowed Eigen-Decomposition Algorithm for Motion Artifact Reduction in Optical Coherence Tomography-Based Angiography
Optical coherence tomography-based angiography (OCTA) has attracted attention in clinical applications as a non-invasive and high-resolution imaging modality. Motion artifacts are the most seen artifact in OCTA. Eigen-decomposition (ED) algorithms are popular choices for OCTA reconstruction, but have limitations in the reduction of motion artifacts. The OCTA data do not meet one of the requirements of ED, which is that the data should be normally distributed. To overcome this drawback, we propose an easy-to-deploy development of ED, windowed-ED (wED). wED applies a moving window to the input data, which can contrast the blood-flow signals with significantly reduced motion artifacts. To evaluate our wED algorithm, pre-acquired dorsal wound healing data in a murine model were used. The ideal window size was optimized by fitting the data distribution with the normal distribution. Lastly, the cross-sectional and en face results were compared among several OCTA reconstruction algorithms, Speckle Variance, A-scan ED (aED), B-scan ED, and wED. wED could reduce the background noise intensity by 18% and improve PSNR by 4.6%, compared to the second best-performed algorithm, aED. This study can serve as a guide for utilizing wED to reconstruct OCTA images with an optimized window size.