IVIasmin Oliveira de Sousa Viana

Iasmin Oliveira de Sousa Viana

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iasmin Oliveira de Sousa Viana has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Working memory: Development, test-retest reliability, and sensitivity of the Digit Span computerized task during physical exercise

    by Thais Frois, Ligia Linhares, Andressa Eliza, Iasmin Oliveira, Tércio Apolinário-Souza, Maicon R. Albuquerque

    Working memory, inhibitory control, and cognitive flexibility are the core components of executive functions, which play a crucial role in sports and physical exercise by influencing problem-solving, logical reasoning, and decision-making. Physical activity also triggers neurobiological changes in the brain, such as increased oxygenation, neurotransmitter release, and elevated body temperature. Therefore, developing tests that assess specific executive function components during exercise is essential for understanding brain behavior in this context. This study aimed to evaluate the reliability and sensitivity of the computerized Digit Span task in assessing working memory during physical exercise. Eleven healthy men participated on three days with a one-week interval between visits. Participants completed questionnaires, anthropometric measurements, and a maximal cardiopulmonary exercise test during the first visit. On the second and third visits, they familiarized themselves with the computerized digit span before engaging in a 30 minute moderate exercise protocol. The task was then performed during exercise for an average of 10 minutes. The results demonstrated good reliability for minimum heart rate (HR) and excellent reliability for maximum and average HR. However, the reliability of the computerized digit span measures was moderate. Sensitivity analysis showed that typical error of measurement values were lower than the smallest worthwhile change thresholds of 0.2, 0.6, and 1.2 for the variables correct trials × span, correct trials, and Span, respectively. This study focused on adapting the traditional digit span for use during physical exercise, evaluating its reliability and sensitivity. HR measures remained consistent, but task reliability was moderate, particularly in the backward condition. These findings highlight the need for methodological improvements to enhance the task's reliability in sports contexts.


  • Do executive function performance, gaze behavior, and pupil size change during incremental acute physical exercise?

    by Maicon Rodrigues Albuquerque, Beatriz Hooper, Iasmin Oliveira de Sousa Viana, Paulo H. C. Mesquita, Tony Meireles Santos, Tércio Apolinário‐Souza, Leonardo de Sousa Fortes, Dawit Albieiro Pinheiro Gonçalves

    Several studies have investigated the interaction between acute physical exercise and cognitive performance. However, few studies have investigated this issue during acute high‐intensity exercise. In the present study, we evaluated executive functions (EFs) during incremental exercise in three different intensities [below lactate threshold (LT), at LT, and above LT], measuring EFs performance, gaze behavior, and pupil diameter. Twenty subjects were familiarized with the EFs test and participated in a graded maximal exercise test on a cycle ergometer on the first visit. On the second visit, they performed the EFs task at rest and while exercising at three different intensities using mobile eye‐tracking glasses. Our results showed that the psychophysiological measures differed between the conditions. Regarding EFs performance, during exercise above LT, the subjects showed worse accuracy when compared with rest (p < .001) and below LT (p < .001). In addition, the response time (RT) at LT and above LT was shorter than in the rest condition (p < .050). Further, RT was faster (p = .002) in the above LT than in the below LT condition. In addition, the gaze behavior measures indicated that exercise, independently of the intensity, improves the number of fixations with shorter fixation durations compared to the rest condition (p < .050). Additionally, we found no significant differences in average and peak pupil diameter between conditions. In conclusion, exercise at LT improves the EFs performance while exercising above LT worsens EFs performance. However, there were no significant differences in average and peak pupil diameter between conditions.