Ziwen Shang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ziwen Shang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Li
Changchun Institute of Technology Changchun China
2 shared publications - Minzhen Wang
National Local Joint Engineering Research Center for Smart Distribution grid Measurement and control with Safety Operation Technology, Changchun Institute of Technology, Changchun 130012, China
2 shared publications - Xinheng Wang
School of Advanced Technology, Xian Jiaotong-Liverpool University, Suzhou, China
2 shared publications - Yongsheng Yang
National Local Joint Engineering Research Center for Smart Distribution grid Measurement and control with Safety Operation Technology, Changchun Institute of Technology, Changchun 130012, China
2 shared publications - Liying Zhao
National Local Joint Engineering Research Center for Smart Distribution grid Measurement and control with Safety Operation Technology, Changchun Institute of Technology, Changchun 130012, China
1 shared publication - Qi Zhang
National Local Joint Engineering Research Center for Smart Distribution grid Measurement and control with Safety Operation Technology, Changchun Institute of Technology, Changchun 130012, China
1 shared publication
Latest Publications
- Open Access
Research on Comprehensive Evaluation and Early Warning of Transmission Lines’ Operation Status Based on Dynamic Cloud Computing
The current methods for evaluating the operating condition of electricity transmission lines (ETLs) and providing early warning have several problems, such as the low correlation of data, ignoring the influence of seasonal factors, and strong subjectivity. This paper analyses the sensitive factors that influence dynamic key evaluation indices such as grounding resistance, sag, and wire corrosion, establishes the evaluation criteria of the ETL operation state, and proposes five ETL status levels and seven principles for selecting evaluation indices. Nine grade I evaluation indices and twenty-nine grade II evaluation indices, including passageway and meteorological environments, are determined. The cloud model theory is embedded and used to propose a warning technology for the operation state of ETLs based on inspection defect parameters and the cloud model. Combined with the inspection defect parameters of a line in the Baicheng district of Jilin Province and the critical evaluation index data such as grounding resistance, sag, and wire corrosion, which are used to calculate the timeliness of the data, the solid line is evaluated. The research shows that the dynamic evaluation model is correct and that the ETL status evaluation and early warning method have reasonable practicability.
Open AccessResearch on Comprehensive Evaluation and Early Warning of Transmission Lines’ Operation Status Based on Dynamic Cloud Computing
The current methods for evaluating the operating condition of electricity transmission lines (ETLs) and providing early warning have several problems, such as the low correlation of data, ignoring the influence of seasonal factors, and strong subjectivity. This paper analyses the sensitive factors that influence dynamic key evaluation indices such as grounding resistance, sag, and wire corrosion, establishes the evaluation criteria of the ETL operation state, and proposes five ETL status levels and seven principles for selecting evaluation indices. Nine grade I evaluation indices and twenty-nine grade II evaluation indices, including passageway and meteorological environments, are determined. The cloud model theory is embedded and used to propose a warning technology for the operation state of ETLs based on inspection defect parameters and the cloud model. Combined with the inspection defect parameters of a line in the Baicheng district of Jilin Province and the critical evaluation index data such as grounding resistance, sag, and wire corrosion, which are used to calculate the timeliness of the data, the solid line is evaluated. The research shows that the dynamic evaluation model is correct and that the ETL status evaluation and early warning method have reasonable practicability.
- Open Access
- 28 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 407
A Novel Monocular Vision Technique for the Detection of Electric Transmission Tower Tilting Trend
Transmission lines are primarily deployed overhead, and the transmission tower, acting as the fulcrum, can be affected by the unbalanced force of the wire and extreme weather, resulting in the transmission tower tilt, deformation, or collapse. This can jeopardize the safe operation of the power grid and even cause widespread failures, resulting in significant economic losses. Given the limitations of current tower tilt detection methods, this paper proposes a tower tilt detection and analysis method based on monocular vision images. The monocular camera collects the profile and contour features of the tower, and the tower tilt model is combined to realize the calculation and analysis of the tower tilt. Through this improved monocular visual monitoring method, the perception accuracy of the tower tilt is improved by 7.5%, and the axial eccentricity is accurate to ±2 mm. The method provides real-time reliability and simple operation for detecting tower inclination, significantly reducing staff inspection intensity and ensuring the power system operates safely and efficiently.
- 28 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 407
Open AccessA Novel Monocular Vision Technique for the Detection of Electric Transmission Tower Tilting Trend
Transmission lines are primarily deployed overhead, and the transmission tower, acting as the fulcrum, can be affected by the unbalanced force of the wire and extreme weather, resulting in the transmission tower tilt, deformation, or collapse. This can jeopardize the safe operation of the power grid and even cause widespread failures, resulting in significant economic losses. Given the limitations of current tower tilt detection methods, this paper proposes a tower tilt detection and analysis method based on monocular vision images. The monocular camera collects the profile and contour features of the tower, and the tower tilt model is combined to realize the calculation and analysis of the tower tilt. Through this improved monocular visual monitoring method, the perception accuracy of the tower tilt is improved by 7.5%, and the axial eccentricity is accurate to ±2 mm. The method provides real-time reliability and simple operation for detecting tower inclination, significantly reducing staff inspection intensity and ensuring the power system operates safely and efficiently.