P. Vaidya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P. Vaidya has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Amanda Thounaojam
Indian Institute for Human Settlements, Bengaluru
2 shared publications - A. De
School of Planning and Architecture, New Delhi
1 shared publication - D. Sinha
Indian Institute for Human Settlements, Bengaluru
1 shared publication - D. Uthej
Indian Institute for Human Settlements, Bengaluru
1 shared publication - Gopikrishna
Indian Institute for Human Settlements, Bengaluru
1 shared publication - M. Maskarenj
Catholic University of Louvain, Louvain-la-Neuve
1 shared publication
Latest Publications
- 27 December 2022
- Published by Sri Lanka Journals Online in FARU Journal
- Vol. 9 (2) , 113-120
Luminance Measurements using Smartphone Cameras
We evaluate the daylight performance visual comfort buildings by measuring light in luminance and illuminance using luminance and lux meter respectively. Detailed measurements of illuminance in a space using these methods on a grid can be time-consuming, while luminance meters to measure luminance values are quite expensive. Recent studies indicate that luminance-based metrics have the best fit to occupant responses in visual comfort surveys. But High Dynamic Range (HDR) techniques can quickly capture a large field of view at a high resolution and can be done with DSLR cameras that are more accessible than luminance meters. This research goes one step further to evaluate the HDR acquisition method using even more accessible smartphone cameras. The method includes calibration of the HDR images using lux meters which are affordable and easily available. A variety of smartphone cameras were evaluated in a wide range of brightness conditions in a scene. The error between the low-cost HDR approach and the conventional approach of HDR imaging is determined and a method for correction factors is proposed. Vignetting corrections for the smartphone camera lens have been demonstrated. A visual comfort survey of a primarily daylit workshop space is done to document as a test case to evaluate the feasibility and accuracy of the low-cost HDR approach. Lux meter for calibration of HDRI images is found to be reasonably accurate (average error of 7%). Of the 6 smartphones studied, the maximum luminance was captured by iPhone 6 and which could only capture 17% of the measured luminance. The fisheye lens used in this study increases the FOV from 68º (no fisheye) to 136° (with fisheye) but the FOV outside 100° was not useful due to large vignetting effect.
- 27 December 2022
- Published by Sri Lanka Journals Online in FARU Journal
- Vol. 9 (2) , 113-120
Luminance Measurements using Smartphone Cameras
We evaluate the daylight performance visual comfort buildings by measuring light in luminance and illuminance using luminance and lux meter respectively. Detailed measurements of illuminance in a space using these methods on a grid can be time-consuming, while luminance meters to measure luminance values are quite expensive. Recent studies indicate that luminance-based metrics have the best fit to occupant responses in visual comfort surveys. But High Dynamic Range (HDR) techniques can quickly capture a large field of view at a high resolution and can be done with DSLR cameras that are more accessible than luminance meters. This research goes one step further to evaluate the HDR acquisition method using even more accessible smartphone cameras. The method includes calibration of the HDR images using lux meters which are affordable and easily available. A variety of smartphone cameras were evaluated in a wide range of brightness conditions in a scene. The error between the low-cost HDR approach and the conventional approach of HDR imaging is determined and a method for correction factors is proposed. Vignetting corrections for the smartphone camera lens have been demonstrated. A visual comfort survey of a primarily daylit workshop space is done to document as a test case to evaluate the feasibility and accuracy of the low-cost HDR approach. Lux meter for calibration of HDRI images is found to be reasonably accurate (average error of 7%). Of the 6 smartphones studied, the maximum luminance was captured by iPhone 6 and which could only capture 17% of the measured luminance. The fisheye lens used in this study increases the FOV from 68º (no fisheye) to 136° (with fisheye) but the FOV outside 100° was not useful due to large vignetting effect.
- 27 December 2022
- Published by Sri Lanka Journals Online in FARU Journal
- Vol. 9 (2) , 12-19
Implementing At-Scale Adaptive Thermal Comfort Controls for Mixed Mode Building Using Machine Learning
With climate change, low carbon space-cooling approaches are becoming more important. The adaptive comfort model for mixed mode operation can be a promising approach to the cooling energy challenge. However, adaptive models use indoor operative temperature, which requires the measurement of air temperature, air velocity, and globe temperature in a space. Collecting real-time and long-term data for these is difficult. We used machine learning to predict operative temperature with minimum measurement equipment, for controls to optimise fan operation and minimise AC energy use. Field measurements and Energy Plus simulation were used to create large datasets, 75 % of which were used to train the machine learning algorithm to predict operating temperature, and the remaining 25% were used for testing the algorithm. The random forest model in R from the tidymodels library using the ranger engine proved successful. The Operative Temperature prediction Root Means Square Error value is 0.090°C. The algorithm classified data for being in/out of the comfort band, and 0.88% of the values are misclassified. While this paper demonstrates the machine learning approach that makes this possible, future work will demonstrate the implementation of the control algorithm and its testing.
- 27 December 2022
- Published by Sri Lanka Journals Online in FARU Journal
- Vol. 9 (2) , 12-19
Implementing At-Scale Adaptive Thermal Comfort Controls for Mixed Mode Building Using Machine Learning
With climate change, low carbon space-cooling approaches are becoming more important. The adaptive comfort model for mixed mode operation can be a promising approach to the cooling energy challenge. However, adaptive models use indoor operative temperature, which requires the measurement of air temperature, air velocity, and globe temperature in a space. Collecting real-time and long-term data for these is difficult. We used machine learning to predict operative temperature with minimum measurement equipment, for controls to optimise fan operation and minimise AC energy use. Field measurements and Energy Plus simulation were used to create large datasets, 75 % of which were used to train the machine learning algorithm to predict operating temperature, and the remaining 25% were used for testing the algorithm. The random forest model in R from the tidymodels library using the ranger engine proved successful. The Operative Temperature prediction Root Means Square Error value is 0.090°C. The algorithm classified data for being in/out of the comfort band, and 0.88% of the values are misclassified. While this paper demonstrates the machine learning approach that makes this possible, future work will demonstrate the implementation of the control algorithm and its testing.