YJYuxuan Jiang

Yuxuan Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuxuan Jiang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Congbiao Lei

    Key Laboratory of Optoelectronic Materials and Devices, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, China

    7 shared publications
  • Liang Xie

    Key Laboratory of Optoelectronic Materials and Devices, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, China

    6 shared publications
  • Mingqi Jiao

    Zhengzhou University

    3 shared publications
  • Ping Gong

    State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China

    3 shared publications
  • Guangcheng Zhong

    Key Laboratory of Optoelectronic Materials and Devices, Institute of Semiconductors Chinese Academy of Sciences, Beijing, China

    2 shared publications
  • Jiaqi Yao

    State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China

    2 shared publications

Latest Publications

  • An Improved Multimode TRL Calibration Method to 110 GHz Based on Coplanar Grounded Waveguides

    by Yuxuan Jiang, Changming Liu, Shirong Lv, Congbiao Lei, Guangcheng Zhong, Ping Gong, Shengli Zhang, Liang Xie

    The multimode thru-reflect-line (TRL) algorithm is widely used for on-wafer differential circuit calibration. This paper presents the design and calibration of coplanar grounded waveguide (GCPW) based calibration kits. Based on the original algorithm, we optimise the reflect standard symbol determination algorithm. The impedance transformation algorithm is added so that the algorithm can be applied to calibrating strongly coupled devices. An improved algorithm and the designed calibration kits enabled precise calibration from 0.1 GHz to 110 GHz. The conventional multimode TRL algorithm line standards have a narrow calibration range and require manual selection. In this paper, an algorithm for selecting line standards is proposed, which automatically selects line standards with minor errors and expands the calibration frequency of line standards. Finally, the error of the improved multimode TRL algorithm is quantitatively analysed and discussed.


  • Photonic scheme for the simultaneous measurement of Doppler frequency shift and angle of arrival based on optical frequency shift heterodyne and power mapping

    by Mingqi Jiao, Lei Li, Yuxuan Jiang, Congbiao Lei, Liang Xie

    A photonic-assisted scheme based on optical frequency shift heterodyne and low-frequency power mapping is proposed and experimentally demonstrated to measure the Doppler frequency shift (DFS) and Angle-of-arrival (AOA) of the microwave signals. In the proposed system, the optical signal is divided into two paths. The upper optical signal is injected into a dual-drive Mach-Zehnder modulator (DDMZM) and modulated by the two echo signals with a phase difference. The lower path optical signal is frequency-shifted by an acousto-optic modulator (AOM) and then modulated by the transmitted signal via a Mach-Zehnder modulator (MZM). After an optical filter, the two first-order sideband optical signals heterodyne in the photodetector. The DFS without direction ambiguity and AOA are mapped to the frequency shift and power of the low-frequency microwave signal. By adjusting the DC bias of the DDMZM, two power-phase mapping curves are obtained to eliminate phase ambiguity in AOA measurement. The measurement accuracy is enhanced by adjusting the identity of the two power mapping curves in different measurement ranges. A proof-of-concept experiment demonstrates a DFS measurement at 20 GHz with errors less than ± 8 Hz in the range of ±100 kHz and an AOA measurement from −62.5° to 62.5° with no more than ±2.5° errors.


  • Calibration-free scheme for frequency response measurement of a Mach–Zehnder modulator with low-frequency detection

    by Mingqi Jiao, Lei Li, Yuxuan Jiang, Congbiao Lei, Liang Xie

    This paper presents a novel, to the best of our knowledge, calibration-free scheme for measuring the frequency response of Mach–Zehnder modulation (MZM) using low-frequency detection. An auxiliary MZM1 modulated by a MHz-level electrical signal f1 is utilized to generate a double-sideband optical signal, which is subsequently directed into the device under test (MZM2). The MZM2 is biased at its minimum point and driven by a frequency-swept microwave signal f m . After photoelectric converting, a fixed low-frequency electrical signal f L carrying the frequency response information of the MZM2 is generated. By sweeping f m while extracting the amplitude of f L , the frequency response of the MZM2 free from the response of the photodetector (PD) is thus determined. In the experiment, the frequency response of a commercial MZM is characterized in the frequency range from 0.1 GHz to 20 GHz with a resolution of 50 MHz. The measurement result is consistent with the vector network analyzer swept method. In addition, the new method eliminates errors introduced by the PD and reduces the requirement for a high-bandwidth PD.

  • Open Access

    A TO-CAN DFB Laser With Transmission Line Impedance Transformer for Analog Optical Link

    by Congbiao Lei, Yuxuan Jiang, Guangcheng Zhong, Liang Xie

    A transmission line(TL) impedance transformer of through-hole (TO)-CAN distributed feedback (DFB) laser is proposed and fabricated. The gain and noise factor(NF) of analog optical link can be improved by optimizing the laser impedance matching network. The radio frequency(RF) package of DFB is optimized to extend bandwidth and reduce return loss. In this paper, a flexible printed circuit(FPC) with low-loss impedance matching network is designed to improved the RF characteristics of TO-CAN DFB laser. The return path between FPC and TO-CAN is optimized to eliminate microwave resonances. The small signal model of an analog optical link is analyzed in detail. The measured frequency response of the TO-CAN DFB is 18.4 GHz. The microwave reflection is below -10 dB. The measured results correlates perfectly with the simulated results. The gain of analog optical link is increased by 3 dB. The NF is also reduced by about 2.5 dB.


  • Open Access

    A Compact NO2 Gas Sensor with an Optimized Photoacoustic Cell and 450 nm-LD

    by Wenyang Yuan, Jiaqi Yao, Ping Gong, Mingqi Jiao, Congbiao Lei, Yuxuan Jiang, Liang Xie

    In this paper, a compact ambient gas sensor with an optimized photoacoustic cell is reported. The relationship between the geometric dimensions (usually radius and length) of the photoacoustic cell (PAC) and the acoustic signal was studied through theoretical and finite element analysis. Then an optimized H-type PAC with a volume of 80 mm × 30 mm × 30 mm was machined out. The gas capacity is only 18.85 millilitres. The performance of the photoacoustic cell has been verified experimentally by the detection of nitrogen dioxide (NO2) standard gas. With an electret microphone and an economically self-designed 450 nm laser module, the detection of NO2 concentration was executed. The experimental results show good linearity with a fitting R-square of 0.9991. With an SNR (signal-to-noise ratio) of 41.247, the minimum detection limit (MDL) of the system can reach 4.85 ppb (1σ). With an analysis of allan variance, the MDL can achieve 0.11 ppb with a 228 s integration time. By replacing the light source, the system shows great potential for sensitive and compact detectors for other ambient gasses as well.


  • Open Access

    Optical Microwave Waveforms Generation Based on the Round-Trip Phase of the DFB Laser

    by Congbiao Lei, Wenyang Yuan, Guangcheng Zhong, Yuxuan Jiang, Mingqi Jiao, Jiaqi Yao, Liang Xie

    In this paper, we theoretically and experimentally analyze the influence of the round-trip phase of distributed feedback (DFB) lasers on the harmonic-phase of photocurrent, caused by the external injection current. The results indicate that the harmonic-phase of photocurrent introduced by the round-trip phase (HPIRP) reduces with the increase of modulation depth at a fixed frequency. Then, based on the HPIRP of the DFB laser, a simple photonic generation method of optical microwave waveforms is proposed and verified. In this scheme, three lasers with different wavelengths are mainly used. By adjusting the tunable optical delay lines and attenuators, the amplitude and phase of the photocurrent of the three branches converted by the photodetector (PD) can be controlled individually. The photocurrent of the superposition of the three branches can be controlled properly to form the target waveform. Dispersive elements and complex microwave photonic filtering are not required. Through experiments, rectangular and triangular waveforms with a repetition frequency of 3.75 GHz are generated.


  • Frequency Response Measurement Method of Photodetector Based on Multiple Harmonics

    by Yuxuan Jiang, Mingqi Jiao, Congbiao Lei, Jiaqi Yao, Wenyang Yuan, Ping Gong, Liang Xie

    This letter proposes a simple method for measuring frequency responses of photodetectors (PDs) based on the multiple harmonic responses of a direct-modulated laser (DML). This method provides numerous harmonics as carriers for subsequent Mach–Zehnder modulator (MZM) modulation based on the nonlinear effect of the direct modulation laser. The modulated signal is injected into the photodetector under test, and the frequency response of the photodetector detector is obtained by sampling the MZM modulation component around multiple harmonics on the electronics spectrum analyzer (ESA). By measuring the relative amplitude of the modulation components around different harmonics, measurement error caused by harmonic amplitude differences can be eliminated. This method greatly expands the measurement range of the frequency response from DC to 2nfm. Moreover, since the modulator modulation frequency range occupies only $\frac {1}{2{\mathrm {n}}}$ of the entire measurement range, the uneven frequency response caused by the modulator is reduced, and extra calibration is avoided. According to this method, we use a 35GHz Mach-Zehnder modulator to measure the frequency response of photodetectors with the bandwidth of 35GHz and 50GHz, respectively. We also compared our method with those conventional methods, and the results show that the method which has a wide frequency response can accurately measure the frequency response of the PD under the condition of the method.