Jean Bismuth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean Bismuth has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Dipan J. Shah
Houston Methodist DeBakey Heart & Vascular Center, Houston, Texas, USA
4 shared publications - Christie M. Ballantyne
Department of Medicine, Baylor College of Medicine, Houston, TX (C.M.B.).
3 shared publications - Dean J. Arnaoutakis
Division of Vascular Surgery, University of South Florida College of Medicine, Tampa, FL
3 shared publications - Gerd Brunner
Penn State Heart and Vascular Institute, Pennsylvania State University College of Medicine, Hershey, United States of America
3 shared publications - Maria Katsarou
Department of Vascular Surgery, A. Manzoni Hospital, Lecco, Italy
3 shared publications - Shivam Patel
University of South Florida Morsani College of Medicine, Tampa, USA
3 shared publications
Latest Publications
- 8 September 2026
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (3) , e77
Nonsyndromic familial type B aortic dissection exhibits distinct clinical profiles and operative outcomes
- 8 September 2026
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (3) , e77
Nonsyndromic familial type B aortic dissection exhibits distinct clinical profiles and operative outcomes
- 2 May 2026
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 84 (3) , 571-584.e1
Nonsyndromic familial type B aortic dissection exhibits distinct clinical profiles and operative outcomes
- 2 May 2026
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 84 (3) , 571-584.e1
Nonsyndromic familial type B aortic dissection exhibits distinct clinical profiles and operative outcomes
- 21 August 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
Aortic Compliance: A Narrative Review
Aortic compliance, the ability of the aorta to expand and recoil with each cardiac cycle, plays a crucial role in cardiovascular function and health. The present review explores the physiology of aortic compliance, evolution of various modalities and techniques to evaluate arterial stiffness, factors influencing compliance, and the clinical implications of aortic compliance when performing interventions on the aorta. Clinical Impact: A comprehensive understanding of endovascular approaches to the ascending aorta, including the aortic arch, is fundamental to evaluating the ongoing evolution of device technology and its integration with contemporary surgical strategies.
- 21 August 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
Aortic Compliance: A Narrative Review
Aortic compliance, the ability of the aorta to expand and recoil with each cardiac cycle, plays a crucial role in cardiovascular function and health. The present review explores the physiology of aortic compliance, evolution of various modalities and techniques to evaluate arterial stiffness, factors influencing compliance, and the clinical implications of aortic compliance when performing interventions on the aorta. Clinical Impact: A comprehensive understanding of endovascular approaches to the ascending aorta, including the aortic arch, is fundamental to evaluating the ongoing evolution of device technology and its integration with contemporary surgical strategies.
- 29 July 2025
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 82 (6) , 1957-1965
Differences in aortic remodeling in patients with type 1a and type 5 endoleak who undergo salvage with fenestrated/branched endovascular aortic repair
- 29 July 2025
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 82 (6) , 1957-1965
Differences in aortic remodeling in patients with type 1a and type 5 endoleak who undergo salvage with fenestrated/branched endovascular aortic repair
- 26 June 2025
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 82 (6) , 1947-1956.e3
Large endograft diameter is associated with poor outcomes following thoracic endovascular aortic aneurysm repair in Medicare beneficiaries
- 26 June 2025
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 82 (6) , 1947-1956.e3
Large endograft diameter is associated with poor outcomes following thoracic endovascular aortic aneurysm repair in Medicare beneficiaries
- Open Access
- 14 June 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (6) , 181
Contrast-Enhanced Magnetic Resonance Imaging Based T1 Mapping and Extracellular Volume Fractions Are Associated with Peripheral Artery Disease
Background: Extracellular volume fraction (ECV), measured with contrast-enhanced magnetic resonance imaging (CE-MRI), has been utilized to study myocardial fibrosis, but its role in peripheral artery disease (PAD) remains unknown. We hypothesized that T1 mapping and ECV differ between PAD patients and matched controls. Methods and Results: A total of 37 individuals (18 PAD patients and 19 matched controls) underwent 3.0T CE-MRI. Skeletal calf muscle T1 mapping was performed before and after gadolinium contrast with a motion-corrected modified look–locker inversion recovery (MOLLI) pulse sequence. T1 values were calculated with a three-parameter Levenberg–Marquardt curve fitting algorithm. ECV and T1 maps were quantified in five calf muscle compartments (anterior [AM], lateral [LM], and deep posterior [DM] muscle groups; soleus [SM] and gastrocnemius [GM] muscles). Averaged peak blood pool T1 values were obtained from the posterior and anterior tibialis and peroneal arteries. T1 values and ECV are heterogeneous across calf muscle compartments. Native peak T1 values of the AM, LM, and DM were significantly higher in PAD patients compared to controls (all p < 0.028). ECVs of the AM and SM were significantly higher in PAD patients compared to controls (AM: 26.4% (21.2, 31.6) vs. 17.3% (10.2, 25.1), p = 0.046; SM: 22.7% (19.5, 27.8) vs. 13.8% (10.2, 19.1), p = 0.020). Conclusions: Native peak T1 values across all five calf muscle compartments, and ECV fractions of the anterior muscle group and the soleus muscle were significantly elevated in PAD patients compared with matched controls. Non-invasive T1 mapping and ECV quantification may be of interest for the study of PAD.
- 14 June 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (6) , 181
Open AccessContrast-Enhanced Magnetic Resonance Imaging Based T1 Mapping and Extracellular Volume Fractions Are Associated with Peripheral Artery Disease
Background: Extracellular volume fraction (ECV), measured with contrast-enhanced magnetic resonance imaging (CE-MRI), has been utilized to study myocardial fibrosis, but its role in peripheral artery disease (PAD) remains unknown. We hypothesized that T1 mapping and ECV differ between PAD patients and matched controls. Methods and Results: A total of 37 individuals (18 PAD patients and 19 matched controls) underwent 3.0T CE-MRI. Skeletal calf muscle T1 mapping was performed before and after gadolinium contrast with a motion-corrected modified look–locker inversion recovery (MOLLI) pulse sequence. T1 values were calculated with a three-parameter Levenberg–Marquardt curve fitting algorithm. ECV and T1 maps were quantified in five calf muscle compartments (anterior [AM], lateral [LM], and deep posterior [DM] muscle groups; soleus [SM] and gastrocnemius [GM] muscles). Averaged peak blood pool T1 values were obtained from the posterior and anterior tibialis and peroneal arteries. T1 values and ECV are heterogeneous across calf muscle compartments. Native peak T1 values of the AM, LM, and DM were significantly higher in PAD patients compared to controls (all p < 0.028). ECVs of the AM and SM were significantly higher in PAD patients compared to controls (AM: 26.4% (21.2, 31.6) vs. 17.3% (10.2, 25.1), p = 0.046; SM: 22.7% (19.5, 27.8) vs. 13.8% (10.2, 19.1), p = 0.020). Conclusions: Native peak T1 values across all five calf muscle compartments, and ECV fractions of the anterior muscle group and the soleus muscle were significantly elevated in PAD patients compared with matched controls. Non-invasive T1 mapping and ECV quantification may be of interest for the study of PAD.
- 8 November 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
Sex-Specific Morphometric Analysis of Ascending Aorta and Aortic Arch for Planning Thoracic Endovascular Aortic Repair: A Retrospective Cohort Study
Objective: In many studies on aortic disease, women are underrepresented. The present study aims to assess sex-specific morphometric differences and gain more insight into endovascular treatment of the ascending aorta (AA) and arch. Methods: Electrocardiogram-gated cardiac computed tomography scans of 116 consecutive patients who were evaluated for transcatheter aortic valve replacement were retrospectively reviewed. Measurements of the AA and aortic arch were made in multiplanar views, perpendicular to the semi-automatic centerline. Multiple linear regression analysis was performed to identify predictors affecting AA and aortic arch diameter in men and women. Propensity score matching was used to investigate whether sex influences aortic morphology. Results: In both sexes, body surface area (BSA) was identified as a positive predictor and diabetes as a negative predictor for aortic diameters. In men, age was identified as a positive predictor and smoking as a negative predictor for aortic diameters. Propensity score matching identified 40 pairs. Systolic and diastolic mean diameters and AA length were significantly wider in men. On average, male aortas were 7.4% wider than female aortas, both in systole and diastole. Conclusions: The present analysis demonstrates that, in women, increased BSA is associated with increased aortic arch diameters, while diabetes is associated with decreased AA and arch diameters. In men, increased BSA and age are associated with increased AA and arch diameters, while smoking and diabetes are associated with decreased AA and arch diameters. Men were confirmed to have 7.4% greater AA and arch diameters than women. Clinical Impact: Men had 7.4% greater ascending aorta and arch diameters than women in a retrospective cohort, gated computed tomography-based study of 116 patients. Sex-specific differences in ascending aortic and arch size should be considered by aortic endovascular device manufacturers and physicians when developing ascending and arch endografts and planning aortic interventions.
- 8 November 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
Sex-Specific Morphometric Analysis of Ascending Aorta and Aortic Arch for Planning Thoracic Endovascular Aortic Repair: A Retrospective Cohort Study
Objective: In many studies on aortic disease, women are underrepresented. The present study aims to assess sex-specific morphometric differences and gain more insight into endovascular treatment of the ascending aorta (AA) and arch. Methods: Electrocardiogram-gated cardiac computed tomography scans of 116 consecutive patients who were evaluated for transcatheter aortic valve replacement were retrospectively reviewed. Measurements of the AA and aortic arch were made in multiplanar views, perpendicular to the semi-automatic centerline. Multiple linear regression analysis was performed to identify predictors affecting AA and aortic arch diameter in men and women. Propensity score matching was used to investigate whether sex influences aortic morphology. Results: In both sexes, body surface area (BSA) was identified as a positive predictor and diabetes as a negative predictor for aortic diameters. In men, age was identified as a positive predictor and smoking as a negative predictor for aortic diameters. Propensity score matching identified 40 pairs. Systolic and diastolic mean diameters and AA length were significantly wider in men. On average, male aortas were 7.4% wider than female aortas, both in systole and diastole. Conclusions: The present analysis demonstrates that, in women, increased BSA is associated with increased aortic arch diameters, while diabetes is associated with decreased AA and arch diameters. In men, increased BSA and age are associated with increased AA and arch diameters, while smoking and diabetes are associated with decreased AA and arch diameters. Men were confirmed to have 7.4% greater AA and arch diameters than women. Clinical Impact: Men had 7.4% greater ascending aorta and arch diameters than women in a retrospective cohort, gated computed tomography-based study of 116 patients. Sex-specific differences in ascending aortic and arch size should be considered by aortic endovascular device manufacturers and physicians when developing ascending and arch endografts and planning aortic interventions.
- 21 March 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 31 (4) , 668-674
StemRad MD, An Exoskeleton-Based Radiation Protection System, Reduces Ergonomic Posture Risk Based on a Prospective Observational Study
Objective: Poor ergonomic posture during interventional procedures might lead to increased physical discomfort and work-related musculoskeletal disorders. Adjunctive equipment such as lead aprons (LAs) has been shown to increase ergonomic posture risk (EPR). The objective of this study was to evaluate the effectiveness of StemRad MD (StemRad Ltd., Tel Aviv, Israel), a weightless exoskeleton-based radiation protective ensemble, in reducing EPR on the operator using wearable inertial measurement unit (IMU) sensors. Methods: A prospective, observational study was conducted at an academic hospital. Inertial measurement unit sensors were affixed to the upper back of 9 interventionalists to assess ergonomic risk posture during endovascular procedures while wearing a traditional LA or the StemRad MD radiation protection system. Total fluoroscopy time, procedure type, and ergonomic risk postures were recorded and analyzed. Results: Twenty-one cases were performed with StemRad MD and 30 with LAs. Mean procedure time for the StemRad MD procedures was 48.4±23.3 minutes (range: 24–106 min), and for LA procedures, it was 34.66±25.83 minutes (range: 6–100 min) (p=.060). The operators assumed low-risk ergonomic positions in 96.1% of StemRad MD cases and in 62.9% of LA cases (p=.001), and high-risk ergonomic positions in 0% and 6.2%, respectively (p=.80). Mean EPR score for StemRad MD was 1.16, and for the LA, it was 1.49 (p=.001). Conclusions: StemRad MD significantly reduces the EPR to the torso compared with a LA-based radiation protection system. Clinical Impact: Poor ergonomic posture during interventional procedures might leas to work-related musculoskeletal disorders for healthcare workers. StemRad MD, a weightless, exoskeleton-based radiation protection system was shown to significantly reduce ergonomic posture risk to the torso compared to conventional lead aprons. This might lead to reduced physical discomfort for procedure-based specialists.
- 21 March 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 31 (4) , 668-674
StemRad MD, An Exoskeleton-Based Radiation Protection System, Reduces Ergonomic Posture Risk Based on a Prospective Observational Study
Objective: Poor ergonomic posture during interventional procedures might lead to increased physical discomfort and work-related musculoskeletal disorders. Adjunctive equipment such as lead aprons (LAs) has been shown to increase ergonomic posture risk (EPR). The objective of this study was to evaluate the effectiveness of StemRad MD (StemRad Ltd., Tel Aviv, Israel), a weightless exoskeleton-based radiation protective ensemble, in reducing EPR on the operator using wearable inertial measurement unit (IMU) sensors. Methods: A prospective, observational study was conducted at an academic hospital. Inertial measurement unit sensors were affixed to the upper back of 9 interventionalists to assess ergonomic risk posture during endovascular procedures while wearing a traditional LA or the StemRad MD radiation protection system. Total fluoroscopy time, procedure type, and ergonomic risk postures were recorded and analyzed. Results: Twenty-one cases were performed with StemRad MD and 30 with LAs. Mean procedure time for the StemRad MD procedures was 48.4±23.3 minutes (range: 24–106 min), and for LA procedures, it was 34.66±25.83 minutes (range: 6–100 min) (p=.060). The operators assumed low-risk ergonomic positions in 96.1% of StemRad MD cases and in 62.9% of LA cases (p=.001), and high-risk ergonomic positions in 0% and 6.2%, respectively (p=.80). Mean EPR score for StemRad MD was 1.16, and for the LA, it was 1.49 (p=.001). Conclusions: StemRad MD significantly reduces the EPR to the torso compared with a LA-based radiation protection system. Clinical Impact: Poor ergonomic posture during interventional procedures might leas to work-related musculoskeletal disorders for healthcare workers. StemRad MD, a weightless, exoskeleton-based radiation protection system was shown to significantly reduce ergonomic posture risk to the torso compared to conventional lead aprons. This might lead to reduced physical discomfort for procedure-based specialists.
- Open Access
Contrast-Enhanced Magnetic Resonance Imaging Based T1-Mapping and Extracellular Volume Fractions are Associated with Peripheral Artery Disease
Background Extracellular volume fraction (ECV), measured with contrast-enhanced magnetic resonance imaging (CE-MRI), has been utilized to study myocardial fibrosis but its role in peripheral artery disease (PAD) remains unknown. We hypothesized that T1-mapping and ECV differ between PAD patients and matched-controls. Methods and Results A total of 37 individuals (18 PAD, 19 controls) underwent 3.0T CE-MRI at the mid-calf. T1-mapping was done before and after gadolinium contrast with a motion corrected Modified Look Locker Inversion Recovery (MOLLI) pulse sequence. T1 values were calculated with a 3-parameter Levenberg-Marquardt curve fitting algorithm. T1-maps were quantified in 5 calf muscle compartments (anterior [AM], lateral [LM], and deep posterior [DM] muscle groups; soleus [SM], and gastrocnemius [GM] muscles). Averaged peak blood pool T1 values were obtained from the posterior (PT) and anterior tibialis (AT); and peroneal artery (PE). PAD ECV was calculated for each muscle group. T1 values and ECV are heterogeneous across calf muscle compartments. Native peak T1 values of the AM, LM, and DM were significantly higher in PAD patients compared to controls (all pConclusions Native peak T1 values and ECV fractions of several calf muscle compartments are higher in PAD patients compared with matched-controls. These data suggest a potential utility of ECV to noninvasively determine skeletal muscle fibrosis in PAD.
Open AccessContrast-Enhanced Magnetic Resonance Imaging Based T1-Mapping and Extracellular Volume Fractions are Associated with Peripheral Artery Disease
Background Extracellular volume fraction (ECV), measured with contrast-enhanced magnetic resonance imaging (CE-MRI), has been utilized to study myocardial fibrosis but its role in peripheral artery disease (PAD) remains unknown. We hypothesized that T1-mapping and ECV differ between PAD patients and matched-controls. Methods and Results A total of 37 individuals (18 PAD, 19 controls) underwent 3.0T CE-MRI at the mid-calf. T1-mapping was done before and after gadolinium contrast with a motion corrected Modified Look Locker Inversion Recovery (MOLLI) pulse sequence. T1 values were calculated with a 3-parameter Levenberg-Marquardt curve fitting algorithm. T1-maps were quantified in 5 calf muscle compartments (anterior [AM], lateral [LM], and deep posterior [DM] muscle groups; soleus [SM], and gastrocnemius [GM] muscles). Averaged peak blood pool T1 values were obtained from the posterior (PT) and anterior tibialis (AT); and peroneal artery (PE). PAD ECV was calculated for each muscle group. T1 values and ECV are heterogeneous across calf muscle compartments. Native peak T1 values of the AM, LM, and DM were significantly higher in PAD patients compared to controls (all pConclusions Native peak T1 values and ECV fractions of several calf muscle compartments are higher in PAD patients compared with matched-controls. These data suggest a potential utility of ECV to noninvasively determine skeletal muscle fibrosis in PAD.