Joel G. Opon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joel G. Opon has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Cyma Adoracion Natividad
Center for Structural Engineering and Informatics, MSU—Iligan Institute of Technology, Iligan City 9200, Lanao del Norte, Philippines
1 shared publication - Jerson N. Orejudos
Civil Engineering Department, Mindanao State University—Iligan Institute of Technology, Iligan City 9200, Philippines
1 shared publication - Jun L. Mata
Graduate School of Engineering, Mindanao State University—Iligan Institute of Technology, Iligan City 9200, Philippines
1 shared publication - Sherwin A. Guirnaldo
Department of Mechanical Engineering and Technology, Mindanao State University—Iligan Institute of Technology, Iligan City 9200, Philippines
1 shared publication
Latest Publications
- Open Access
- 24 April 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (9) , 4260
Sustainability-Qualified IEQ Indicators for Academic Buildings: A Systematic Review (2010–2025) and SDG-Aligned Framework
Indoor Environmental Quality (IEQ) strongly influences health, comfort, and learning performance in academic buildings, yet assessment practices remain fragmented and rarely aligned with sustainability goals. This study conducted a PRISMA 2020-guided systematic literature review to identify, screen, and map IEQ indicators for educational facilities and to develop a sustainability-aligned framework for classroom evaluation. Searches of Google Scholar, Scopus, and Web of Science (2010–2025) yielded 365 records; after de-duplication and eligibility screening, 142 peer-reviewed studies were included. From these, 118 unique IEQ indicators were extracted and classified into six domains: thermal comfort, indoor air quality, acoustic quality, visual comfort, environmental quality, and spatial quality. Using sustainability-oriented screening criteria (measurability, relevance, reliability, data accessibility, understandability, and long-term applicability), 50 indicators (42%) were retained as methodologically robust, while 68 (58%) were excluded due to weak standardization or limited practical applicability. The retained indicators were systematically mapped to the environmental, social, and economic pillars and aligned with key SDGs (3, 4, 7, 11, and 13). The resulting Sustainability-Aligned IEQ Indicator Framework integrates quality-screened indicators with pillar/SDG alignment and a mixed-method pathway that combines objective monitoring and occupant perception, supporting context-sensitive evaluation, particularly for naturally ventilated and tropical learning environments.
- 24 April 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (9) , 4260
Open AccessSustainability-Qualified IEQ Indicators for Academic Buildings: A Systematic Review (2010–2025) and SDG-Aligned Framework
Indoor Environmental Quality (IEQ) strongly influences health, comfort, and learning performance in academic buildings, yet assessment practices remain fragmented and rarely aligned with sustainability goals. This study conducted a PRISMA 2020-guided systematic literature review to identify, screen, and map IEQ indicators for educational facilities and to develop a sustainability-aligned framework for classroom evaluation. Searches of Google Scholar, Scopus, and Web of Science (2010–2025) yielded 365 records; after de-duplication and eligibility screening, 142 peer-reviewed studies were included. From these, 118 unique IEQ indicators were extracted and classified into six domains: thermal comfort, indoor air quality, acoustic quality, visual comfort, environmental quality, and spatial quality. Using sustainability-oriented screening criteria (measurability, relevance, reliability, data accessibility, understandability, and long-term applicability), 50 indicators (42%) were retained as methodologically robust, while 68 (58%) were excluded due to weak standardization or limited practical applicability. The retained indicators were systematically mapped to the environmental, social, and economic pillars and aligned with key SDGs (3, 4, 7, 11, and 13). The resulting Sustainability-Aligned IEQ Indicator Framework integrates quality-screened indicators with pillar/SDG alignment and a mixed-method pathway that combines objective monitoring and occupant perception, supporting context-sensitive evaluation, particularly for naturally ventilated and tropical learning environments.
- Open Access
Optimizing Building Orientation and Roof Angle of a Typhoon-Resilient Single-Family House Using Genetic Algorithm and Computational Fluid Dynamics
In the event of a typhoon, the majority of houses suffer from large amounts of damage because they were not built with typhoon resilience in mind. For instance, the Philippines is one of the world’s most vulnerable countries to typhoons. Often, roof structures are ripped off during typhoons with average or more vigorous wind gustiness, and houses are easily ruined. This situation led us to search for the appropriate building orientation and roof angle of single-family residential houses through simulations using MATLAB’s genetic algorithm (GA) and SolidWorks’ computational fluid dynamics (CFD). The GA provides the set of design points, while CFD generates a fitness score for each design point. The goal of the optimization is to determine the orientation and roof angle while minimizing the drag force along the direction of a constant wind speed (315 km/h). The lower and upper bounds for house orientation are 0 and 90, respectively; the roof angle is between 3 and 60. After 100 generations, the GA converged to values equal to an 80 orientation and 11 roof angle. The final results provide a good standpoint for future experiments on physical structures.Open AccessOptimizing Building Orientation and Roof Angle of a Typhoon-Resilient Single-Family House Using Genetic Algorithm and Computational Fluid Dynamics
In the event of a typhoon, the majority of houses suffer from large amounts of damage because they were not built with typhoon resilience in mind. For instance, the Philippines is one of the world’s most vulnerable countries to typhoons. Often, roof structures are ripped off during typhoons with average or more vigorous wind gustiness, and houses are easily ruined. This situation led us to search for the appropriate building orientation and roof angle of single-family residential houses through simulations using MATLAB’s genetic algorithm (GA) and SolidWorks’ computational fluid dynamics (CFD). The GA provides the set of design points, while CFD generates a fitness score for each design point. The goal of the optimization is to determine the orientation and roof angle while minimizing the drag force along the direction of a constant wind speed (315 km/h). The lower and upper bounds for house orientation are 0 and 90, respectively; the roof angle is between 3 and 60. After 100 generations, the GA converged to values equal to an 80 orientation and 11 roof angle. The final results provide a good standpoint for future experiments on physical structures.