Narumol Matsuyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Narumol Matsuyama has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Agnieszka Starek-Wójcicka
Department of Biological Bases of Food and Feed Technologies, Faculty of Production Engineering, University of Life Sciences in Lublin, 20-612 Lublin, Poland
2 shared publications - Joanna Pawłat
Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, Lublin, Poland
2 shared publications - Marta Krajewska
Department of Biological Bases of Food and Feed Technologies, Faculty of Production Engineering, University of Life Sciences in Lublin, 20-612 Lublin, Poland
2 shared publications - Michał Kwiatkowski
Department of Electrical Engineering and Smart Technologies, Lublin University of Technology, Nadbystrzycka Street 38A, 20-618 Lublin, Poland
2 shared publications - Nobuya Hayashi
Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka 816-8580, Japan
2 shared publications - Piotr Terebun
Department of Electrical Engineering and Smart Technologies, Lublin University of Technology, Nadbystrzycka Street 38A, 20-618 Lublin, Poland
2 shared publications
Latest Publications
- Open Access
Impact of DBD Plasma Jet Treatment on the Enamel Surface of Primary Teeth
The impact of cold atmospheric plasma (CAP) treatment on the enamel of twelve primary teeth (incisors, canines, and molars) collected from six children was examined in order to evaluate the possibility of using the CAP technique in dental applications. A radio-frequency dielectric barrier discharge (DBD) plasma jet operating at a voltage of 3.25 kV using a mixture of helium and oxygen as the working gas was used for the generation of plasma as part of the electro-technological method for the treatment of biological material. The plasma exposure time for the primary teeth was 5, 10, and 20 min. The properties of tooth enamel (color, contact angles, surface roughness, surface topography, elemental composition) were examined before (control) and after the plasma treatment. As shown by the results, the plasma treatment time is a key parameter that can induce desired features, such as whitening or improved wettability. However, with prolonged plasma treatment (20 min), the enamel surface may be permanently damaged. The cold-plasma-treated samples were characterized by a higher value of the brightness L* parameter and thus a lighter color, compared to the CAP-untreated teeth. It was also evidenced that the plasma treatment increased the hydrophilicity of tooth surfaces, and the contact angles effectively decreased with the time of the CAP treatment. The tooth surface also became much more heterogeneous and rough with much greater amplitudes in heights. The surface of the primary teeth after the CAP treatment lost its homogeneity, as evidenced by the SEM micrographs. The analysis of the elemental composition revealed only minor changes after the plasma process, which may suggest that the observed morphological changes in the enamel surface are mainly physical and are not a consequence of chemical reactions between the enamel and the reactive components of the cold plasma. Plasma treatment of teeth opens up new possibilities of using this method as an alternative to whitening or pre-treatment before other dental procedures.
Open AccessImpact of DBD Plasma Jet Treatment on the Enamel Surface of Primary Teeth
The impact of cold atmospheric plasma (CAP) treatment on the enamel of twelve primary teeth (incisors, canines, and molars) collected from six children was examined in order to evaluate the possibility of using the CAP technique in dental applications. A radio-frequency dielectric barrier discharge (DBD) plasma jet operating at a voltage of 3.25 kV using a mixture of helium and oxygen as the working gas was used for the generation of plasma as part of the electro-technological method for the treatment of biological material. The plasma exposure time for the primary teeth was 5, 10, and 20 min. The properties of tooth enamel (color, contact angles, surface roughness, surface topography, elemental composition) were examined before (control) and after the plasma treatment. As shown by the results, the plasma treatment time is a key parameter that can induce desired features, such as whitening or improved wettability. However, with prolonged plasma treatment (20 min), the enamel surface may be permanently damaged. The cold-plasma-treated samples were characterized by a higher value of the brightness L* parameter and thus a lighter color, compared to the CAP-untreated teeth. It was also evidenced that the plasma treatment increased the hydrophilicity of tooth surfaces, and the contact angles effectively decreased with the time of the CAP treatment. The tooth surface also became much more heterogeneous and rough with much greater amplitudes in heights. The surface of the primary teeth after the CAP treatment lost its homogeneity, as evidenced by the SEM micrographs. The analysis of the elemental composition revealed only minor changes after the plasma process, which may suggest that the observed morphological changes in the enamel surface are mainly physical and are not a consequence of chemical reactions between the enamel and the reactive components of the cold plasma. Plasma treatment of teeth opens up new possibilities of using this method as an alternative to whitening or pre-treatment before other dental procedures.
- Open Access
- 31 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 578
Quality of Tomato Juice as Influenced by Non-Thermal Air Plasma Treatment
This paper presents the results of an experiment based on using a Glide-arc type plasma reactor operating at atmospheric pressure for the quality of fresh pressed tomato juice, variety Bekas. The impact of after-glow plasma gas (air) on the physicochemical, microbiological properties and morphology of the product’s samples was investigated. Five groups of juices characterized by different exposure times (30, 60, 120, 300 and 600 s), as well as untreated juice (as control) were used. The juice quality was assessed on days 1, 3, 5, and 10 of refrigerated storage. Significant increases were observed when Cold Atmospheric Plasma (CAP)-treated tomato juice was tested against total soluble solids, pH, lycopene, and vitamin C in comparison to the control treatments. Moreover, changes in the tested physicochemical values during the storage of juice subjected to the action of cold plasma did not progress as quickly as in the case of the control juice. A significant decrease was observed in total plate count, yeast, and mold after 300–600 s CAP treatment. The findings of the current study suggested that CAP treatment is a promising technique that could provide improved quality and stability during the processing of tomato juice with better physicochemical properties and bioavailable nutrients.
- 31 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 578
Open AccessQuality of Tomato Juice as Influenced by Non-Thermal Air Plasma Treatment
This paper presents the results of an experiment based on using a Glide-arc type plasma reactor operating at atmospheric pressure for the quality of fresh pressed tomato juice, variety Bekas. The impact of after-glow plasma gas (air) on the physicochemical, microbiological properties and morphology of the product’s samples was investigated. Five groups of juices characterized by different exposure times (30, 60, 120, 300 and 600 s), as well as untreated juice (as control) were used. The juice quality was assessed on days 1, 3, 5, and 10 of refrigerated storage. Significant increases were observed when Cold Atmospheric Plasma (CAP)-treated tomato juice was tested against total soluble solids, pH, lycopene, and vitamin C in comparison to the control treatments. Moreover, changes in the tested physicochemical values during the storage of juice subjected to the action of cold plasma did not progress as quickly as in the case of the control juice. A significant decrease was observed in total plate count, yeast, and mold after 300–600 s CAP treatment. The findings of the current study suggested that CAP treatment is a promising technique that could provide improved quality and stability during the processing of tomato juice with better physicochemical properties and bioavailable nutrients.