ZAZuraida Ahmad

Zuraida Ahmad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zuraida Ahmad has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of Channel Length Variation on the Electrical Conductivity of Passivated Back-Gated Graphene Field-Effect Transistor (GFET) Using Silvaco TCAD Tools

    by Hazim Guzali, Nur Idayu Ayob, Aliza Aini Md Ralib, Mohamad Adzhar Md Zawawi, Cik Rohaida Che Hak, Zuraida Ahmad

    This paper presents the simulation study of passivated backgated graphene field-effect transistors (GFETs) with different channel lengths using Victory Device tool by Silvaco TCAD. The passivated backgated GFETs were designed for radiation device applications. Six GFETs models with channel lengths ranging from 0.1 µm to 10 µm were analyzed to investigate the influence of variation in channel length on the conductivity of GFET. Nearly all devices with shorter channel lengths exhibit ambipolar characteristics with V-shaped curves, indicating the conductivity of holes and electrons at different bias conditions. Interestingly, GFETs with longer channels, specifically 3 µm, 5 µm, and 10 µm, exhibited unexpected W-shaped transfer characteristic curves, featuring multiple charge neutrality points (CNPs). This behavior is attributed to the non-uniform doping induced by charge interactions between the channel and the passivation layer. The central region of the channel may experience a higher doping effect due to impurity diffusion from the passivation material compared to the region near to the metal electrodes. However, the W-shaped curves of longer channel GFETs become less prominent when compared to smaller channel length devices. This suggests that high conductivity in shorter channel GFETs dominates the overall transfer curve performance. The analysis of output characteristics (I D –V D ) at V G = 10 V further supports the influence of channel length on device performance, with the shortest channel length (0.1 µm) recording the highest saturation current (I SAT ), followed closely by 0.6 µm, aligning with its strong ambipolar transfer characteristics. These findings highlight the importance of channel scaling in designing stable and reliable backgated GFETs for radiation applications.

  • Influence of High-Energy Electron Radiation on the Electrical Properties of Back-gated Graphene Field Effect Transistors (GFETs) with Different Passivation Materials

    by Hazim Guzali, Nur Idayu Ayob, Aliza Aini Md Ralib, Mohamad Adzhar Md Zawawi, Cik Rohaida Che Hak, Zuraida Ahmad

    Back-gated graphene field-effect transistors (GFETs) have attracted significant interest owing to graphene’s exceptional carrier mobility and high sensitivity, making them strong candidates for radiation sensing and detection applications. However, prolonged exposure to a high-energy radiation can degrade the graphene structure and impact device performance. This study presents a simulation-based investigation of back-gated GFETs incorporating different passivation materials (Si₃N₄, SiO₂, and Al₂O₃) under high-energy electron beam irradiation. The device modeling and radiation response was simulated using Victory Device tool by Silvaco TCAD. A 3 MeV electron beam at doses of 50, 100, and 200 kGy was irradiated to both passivated and non-passivated GFET models. All devices retained ambipolar characteristics with drain current increasing at 50 kGy and saturating at higher doses of 100-200 kGy. The non-passivated GFET exhibited the highest conductivity, attributed to radiation-induced electron–hole pair generation dominating over defect-related scattering, in agreement with previously reported experimental observations. In contrast, the passivated GFETs showed a slight reduction in conductivity, which is attributed to hole trapping at the graphene-passivation interface, inducing parasitic fields that hinder electron mobility. The charge trapping mechanisms responsible for this behavior are systematically introduced and discussed in this study. Overall, despite exhibiting higher conductivity, the non-passivated GFET lacks structural protection against radiation-induced damage. These findings identify SiO₂ as a promising radiation-hardened passivation material for GFETs and demonstrate the applicability of TCAD tools in modeling radiation effects on 2D material-based devices.

  • Open Access

    Formulation and Characterization of Sertu Kaolin Clay Paste for Cleaning of Medical Equipment and Wound Treatment

    by Zuraida Ahmad, Noorasikin Samat, Norshahida Sarifuddin, Mohd Shukrimi Awang, Aminudin Che-Ahmad, Abdul Rahman Al-Azmi, Ikhwan Yusuff, Nursyazwana Radzi

    The treatment of the wounds inflicted by dogs and wild boars becoming a significant public concern. From Islamic contexts, it demands effective and Shariah-compliant cleaning methods. Current practices predominantly employ soil-based soap, raising questions about its scientific efficacy and safety for wound treatment and medical equipment cleansing. This study is executed to formulate and characterize a Shariah-compliant kaolin clay paste designed for sertu applications in the medical field, for both wound areas and medical equipment cleansing. Kaolin clay was selected as the soil medium in the formulated sertu clay paste and underwent various characterizations, including X-ray Diffraction (XRD), Scanning Electron Microscope (SEM) and Fourier Transform Infrared (FTIR) analyses. XRD analysis confirmed the presence of kaolinite in the kaolin clay. This is also further evidenced by the presence of bonds between Al and Mg ions and hydroxyl groups in the FTIR spectra. The irregular morphology of the kaolin particles observed through SEM, contributed to an increase in surface area, thereby enhancing the interaction between clay and other components. The formulated clay paste was further evaluated through pH measurement, irritation analysis, antimicrobial testing, and corrosion testing to assess its performance. The results indicated that the formulation produced a stable sertu clay paste, with pH values ranging from 8.34 to 9.52 and a primary irritation index (PII) of 4.38 which is within acceptable range for wound treatment. Additionally, the paste proved suitable for cleansing medical instruments, as no significant corrosion or bacterial growth was observed.

  • High energy electron radiation inducing non-homogeneous structural changes on single layer graphene/SiO2/Si substrate

    by Hazim Guzali, Nur Idayu Ayob, Muhammad Naim Hanif Mohamad, Ahmad Syahmi Zamzuri, Cik Rohaida Che Hak, Zuraida Ahmad, Aliza ‘aIni Md Ralib


  • Electrical Resistance of Fabric Immersed with PEDOT:PSS Doped Ag NPs and DMSO Solution

    by Nur’aIshah Ahmad Shahrim, Zuraida Ahmad, Wan Nur’ Alia Nadhirah Wan Solah, Amelia Wong Azman, Norshahida Sarifuddin, Yose Fachmi Buys

  • Open Access

    Ink based on poly(3,4-ethylene dioxythiophene), poly(sulfonostyrene) and silver nanoparticles (PEDOT/PSS/SNP) blends for fabrics printing

    by Nur'AIshah Ahmad Shahrim, Nur Nadia Mohd Hafiz, Zuraida Ahmad, Yose Fachmi Buys, Norshahida Sarifuddin

    The influence of co-solvents such as: dimethylsulfoxide (DMSO), isopropyl alcohol (IPA), ethylene glycol (EG), ethanol (EtOH) and deionized water (DI) on the properties of ink based on poly(3,4-ethylene dioxythiophene), poly(sulfonostyrene) and silver nanoparticles (PEDOT/PSS/SNP) blends was investigated. The ink was obtained by the ultrasonic dispersion method by mixing PEDOT, PSS and SNP and then adding co-solvents. The ink was applied to the cotton fabric by printing method. The structure, electrical and functional properties of fabrics were investigated. The increase in electrical conductivity was found as a result of the phase separation between PEDOT and PSS due to the use of co-solvents. SEM micrographs showed good adhesion of the ink to the cotton fiber, which was confirmed by the FTIR method. The developed ink has great application potential, especially in electronic devices for biomedical purposes.

  • Top Cited Papers
    Open Access

    Mechanisms for doped PEDOT:PSS electrical conductivity improvement

    by Nur'AIshah Ahmad Shahrim, Zuraida Ahmad, Amelia Wong Azman, Yose Fachmi Buys, Norshahida Sarifuddin

    Due to their good electrical conductivity and versatility, conductive polymers like poly(3,4-ethylene dioxythiophene) (PEDOT):poly(styrene sulphonate) (PSS), have recently attracted considerable research interest in bioelectronics applications.


  • Open Access

    Analysis of design tool attributes with regards to sustainability benefits

    by S Zain, A F Ismail, Z Ahmad, E Y T Adesta

    The trend of global manufacturing competitiveness has shown a significant shift from profit and customer driven business to a more harmonious sustainability paradigm. This new direction, which emphasises the interests of three pillars of sustainability, i.e., social, economic and environment dimensions, has changed the ways products are designed. As a result, the roles of design tools in the product development stage of manufacturing in adapting to the new strategy are vital and increasingly challenging. The aim of this paper is to review the literature on the attributes of design tools with regards to the sustainability perspective. Four well-established design tools are selected, namely Quality Function Deployment (QFD), Failure Mode and Element Analysis (FMEA), Design for Six Sigma (DFSS) and Design for Environment (DfE). By analysing previous studies, the main attributes of each design tool and its benefits with respect to each sustainability dimension throughout four stages of product lifecycle are discussed. From this study, it is learnt that each of the design tools contributes to the three pillars of sustainability either directly or indirectly, but they are unbalanced and not holistic. Therefore, the prospective of improving and optimising the design tools is projected, and the possibility of collaboration between the different tools is discussed.


  • Open Access

    Influence of fiber treatment on dimensional stabilities of rattan waste composite boards

    by A Zuraida, Y Insyirah, T Maisarah, H Zahurin

    The main drawback of using natural fibers in composite boards is its hydrophilic properties which absorb a high volume of moisture. This results in low dimensional stability of the produced composite boards. Hence, the purpose of this study is to investigate the effects of fibers' treatment processes of the rattan waste fibers on the dimensional stabilities of composite boards. The collected fibers underwent two types of retting processes, namely a water treatment and alkaline treatment retting processes; where the fibers were soaked in water and a 1% sodium hydroxide (NaOH) solution, respectively. The fibers were dried and mixed with poly(lactic) acid (PLA) pellets with ratio of 30% fibers: 70% matrix; before being fabricated into composite boards via a hot-pressing process and were labelled as RF/PLA, WRF/PLA, CRF/PLA for untreated rattan, rattan treated by water retting, rattan treated by chemical retting, respectively. The produced composite boards were cut and soaked in water for 24 hours for dimensional stability in terms of water absorption and thickness swelling tests. The results showed that WRF/PLA has the lowest water absorption (3.2%), and the CRF/PLA had the highest water absorption (23.2%). The thickness swelling showed a similar trend as water absorption. The presence of void contents and fibers damaged the insides of the boards, which contributed to low dimensional stabilities of the composite boards. It can be concluded that water retting facilitated in improving dimensional stability of the produced composite board.