Chuang Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chuang Wu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Binfeng Yin
School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China
6 shared publications- A. S. M. Muhtasim Fuad Sohan
School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia
5 shared publications - Haithm Yahya Mohammed Almuaalemi
School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China
5 shared publications - Chuang Wu
School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China
3 shared publications - Hanqi Jia
School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China
2 shared publications Haixiang Wang
College of Mechanical Engineering, YangZhou University, Yangzhou, China
1 shared publication
Latest Publications
- RetractionOpen Access
- 28 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 451
RETRACTED: Wu et al. Preparation and Analysis of Structured Color Janus Droplets Based on Microfluidic 3D Droplet Printing. Micromachines 2023, 14, 1911
The Micromachines Editorial Office retracts the article “Preparation and analysis of structured color Janus droplets based on microfluidic 3D droplet printing”
- 28 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 451
RetractionOpen AccessRETRACTED: Wu et al. Preparation and Analysis of Structured Color Janus Droplets Based on Microfluidic 3D Droplet Printing. Micromachines 2023, 14, 1911
The Micromachines Editorial Office retracts the article “Preparation and analysis of structured color Janus droplets based on microfluidic 3D droplet printing”
- RetractedOpen Access
- 7 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1911
RETRACTED: Preparation and Analysis of Structured Color Janus Droplets Based on Microfluidic 3D Droplet Printing
The microfluidic technique for the three-dimensional (3D) printing of Janus droplets offers precise control over their size, orientation, and positioning. The proposed approach investigates the impact of variables such as the volume ratio of the oil phase, droplet size, and the ratio of nonionic surfactants on the dimensions of the structured color apertures of Janus droplets. The findings reveal that structured color apertures modulate accurately. Furthermore, fabricating color patterns facilitates cat, fish, and various other specific shapes using structured color Janus droplets. The color patterns exhibit temperature-sensitive properties, enabling them to transition between display and concealed states. Herein, the adopted microfluidic technique creates Janus droplets with customizable characteristics and uniform size, solving orientation as well as space arrangement problems. This approach holds promising applications for optical devices, sensors, and biomimetic systems.
- 7 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1911
RetractedOpen AccessRETRACTED: Preparation and Analysis of Structured Color Janus Droplets Based on Microfluidic 3D Droplet Printing
The microfluidic technique for the three-dimensional (3D) printing of Janus droplets offers precise control over their size, orientation, and positioning. The proposed approach investigates the impact of variables such as the volume ratio of the oil phase, droplet size, and the ratio of nonionic surfactants on the dimensions of the structured color apertures of Janus droplets. The findings reveal that structured color apertures modulate accurately. Furthermore, fabricating color patterns facilitates cat, fish, and various other specific shapes using structured color Janus droplets. The color patterns exhibit temperature-sensitive properties, enabling them to transition between display and concealed states. Herein, the adopted microfluidic technique creates Janus droplets with customizable characteristics and uniform size, solving orientation as well as space arrangement problems. This approach holds promising applications for optical devices, sensors, and biomimetic systems.
- Open Access
- 10 August 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1577
Structural Optimization Design of Microfluidic Chips Based on Fast Sequence Pair Algorithm
The market for microfluidic chips is experiencing significant growth; however, their development is hindered by a complex design process and low efficiency. Enhancing microfluidic chips’ design quality and efficiency has emerged as an integral approach to foster their advancement. Currently, the existing structural design schemes lack careful consideration regarding the impact of chip area, microchannel length, and the number of intersections on chip design. This inadequacy leads to redundant chip structures resulting from the separation of layout and wiring design. This study proposes a structural optimization method for microfluidic chips to address these issues utilizing a simulated annealing algorithm. The simulated annealing algorithm generates an initial solution in advance using the fast sequence pair algorithm. Subsequently, an improved simulated annealing algorithm is employed to obtain the optimal solution for the device layout. During the wiring stage, an advanced wiring method is used to designate the high wiring area, thereby increasing the success rate of microfluidic chip wiring. Furthermore, the connection between layout and routing is reinforced through an improved layout adjustment method, which reduces the length of microchannels and the number of intersections. Finally, the effectiveness of the structural optimization approach is validated through six sets of test cases, successfully achieving the objective of enhancing the design quality of microfluidic chips.
- 10 August 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1577
Open AccessStructural Optimization Design of Microfluidic Chips Based on Fast Sequence Pair Algorithm
The market for microfluidic chips is experiencing significant growth; however, their development is hindered by a complex design process and low efficiency. Enhancing microfluidic chips’ design quality and efficiency has emerged as an integral approach to foster their advancement. Currently, the existing structural design schemes lack careful consideration regarding the impact of chip area, microchannel length, and the number of intersections on chip design. This inadequacy leads to redundant chip structures resulting from the separation of layout and wiring design. This study proposes a structural optimization method for microfluidic chips to address these issues utilizing a simulated annealing algorithm. The simulated annealing algorithm generates an initial solution in advance using the fast sequence pair algorithm. Subsequently, an improved simulated annealing algorithm is employed to obtain the optimal solution for the device layout. During the wiring stage, an advanced wiring method is used to designate the high wiring area, thereby increasing the success rate of microfluidic chip wiring. Furthermore, the connection between layout and routing is reinforced through an improved layout adjustment method, which reduces the length of microchannels and the number of intersections. Finally, the effectiveness of the structural optimization approach is validated through six sets of test cases, successfully achieving the objective of enhancing the design quality of microfluidic chips.
- Open Access
- 6 July 2023
- Published by MDPI AG in Preprints.org
Structural Optimization Design of Microfluidics Chips Based on Fast Sequence Pair Algorithm
The market for microfluidic chips is experiencing significant growth; however, their development is hindered by a complex design process and low efficiency. Enhancing microfluidic chips’ design quality and efficiency has emerged as an integral approach to foster their advancement. Currently, the existing structural design schemes lack careful consideration regarding the impact of chip area, microchannel length, and the number of intersections on chip design. This inadequacy leads to redundant chip structures resulting from the separation of layout and wiring design. This study proposes a structural optimization method for microfluidic chips to address these issues utilizing a simulated annealing algorithm. The simulated annealing algorithm generates an initial solution in advance using the fast sequence pair algorithm. Subsequently, an improved simulated annealing algorithm is employed to obtain the optimal solution for the device layout. During the wiring stage, an advanced wiring method is used to designate the high wiring area, thereby increasing the success rate of microfluidic chip wiring. Furthermore, the connection between layout and routing is reinforced through an improved layout adjustment method, which reduces the length of microchannels and the number of intersections. Finally, the effectiveness of the structural optimization approach is validated through six sets of test cases, successfully achieving the objective of enhancing the design quality of microfluidic chips.
- 6 July 2023
- Published by MDPI AG in Preprints.org
Open AccessStructural Optimization Design of Microfluidics Chips Based on Fast Sequence Pair Algorithm
The market for microfluidic chips is experiencing significant growth; however, their development is hindered by a complex design process and low efficiency. Enhancing microfluidic chips’ design quality and efficiency has emerged as an integral approach to foster their advancement. Currently, the existing structural design schemes lack careful consideration regarding the impact of chip area, microchannel length, and the number of intersections on chip design. This inadequacy leads to redundant chip structures resulting from the separation of layout and wiring design. This study proposes a structural optimization method for microfluidic chips to address these issues utilizing a simulated annealing algorithm. The simulated annealing algorithm generates an initial solution in advance using the fast sequence pair algorithm. Subsequently, an improved simulated annealing algorithm is employed to obtain the optimal solution for the device layout. During the wiring stage, an advanced wiring method is used to designate the high wiring area, thereby increasing the success rate of microfluidic chip wiring. Furthermore, the connection between layout and routing is reinforced through an improved layout adjustment method, which reduces the length of microchannels and the number of intersections. Finally, the effectiveness of the structural optimization approach is validated through six sets of test cases, successfully achieving the objective of enhancing the design quality of microfluidic chips.
- Open Access
- 25 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1302
Research on Integrated 3D Printing of Microfluidic Chips
Microfluidic chips have the advantages of miniaturization, integration, and portability, and are widely used in the early diagnosis of major diseases, personalized medical treatment, environmental detection, health quarantine, and other fields. The existing microfluidic chip manufacturing process is difficult to operate because of complex three-dimensional channels, complicated manufacturing steps, limited printing materials, the difficulty of operating the bonding process, and the need to purchase expensive new equipment. In this paper, an integrated molding method for microfluidic chips that integrates 3D printing and polymer dissolution technology is proposed. First, the channel mold of poly(vinyl alcohol) (PVA) or high impact polystyrene (HIPS) is dissolved to complete the manufacturing of the microfluidic chip channel. The integrated 3D-forming method of microfluidic chips proposed in this paper can manufacture microchannels inside the microfluidic chip, avoid the bonding process, and eliminate the need for rapid alignment of microchannels, material modification, and other operations, thus improving the stability of the process. Finally, by comparing the microchannels made by PVA and HIPS, it is concluded that the quality of the microchannels made by HIPS is obviously better than that made by PVA. This paper provides a new idea for the fabrication of microfluidic chips and the application of HIPS.
- 25 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1302
Open AccessResearch on Integrated 3D Printing of Microfluidic Chips
Microfluidic chips have the advantages of miniaturization, integration, and portability, and are widely used in the early diagnosis of major diseases, personalized medical treatment, environmental detection, health quarantine, and other fields. The existing microfluidic chip manufacturing process is difficult to operate because of complex three-dimensional channels, complicated manufacturing steps, limited printing materials, the difficulty of operating the bonding process, and the need to purchase expensive new equipment. In this paper, an integrated molding method for microfluidic chips that integrates 3D printing and polymer dissolution technology is proposed. First, the channel mold of poly(vinyl alcohol) (PVA) or high impact polystyrene (HIPS) is dissolved to complete the manufacturing of the microfluidic chip channel. The integrated 3D-forming method of microfluidic chips proposed in this paper can manufacture microchannels inside the microfluidic chip, avoid the bonding process, and eliminate the need for rapid alignment of microchannels, material modification, and other operations, thus improving the stability of the process. Finally, by comparing the microchannels made by PVA and HIPS, it is concluded that the quality of the microchannels made by HIPS is obviously better than that made by PVA. This paper provides a new idea for the fabrication of microfluidic chips and the application of HIPS.
- Open Access
- 21 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1277
Effect of Flow Velocity on Laminar Flow in Microfluidic Chips
Gel fibers prepared based on microfluidic laminar flow technology have important research value in constructing biomimetic scaffolds and tissue engineering. The key point of microfluidic laminar flow technology is to find the appropriate fluid flow rate in the micropipe. In order to explore the influence of flow rate on the laminar flow phenomenon of a microfluidic chip, a microfluidic chip composed of an intermediate main pipe and three surrounding outer pipes are designed, and the chip is prepared by photolithography and the composite molding method. Then, a syringe pump is used to inject different fluids into the microtubing, and the data of fluid motion are obtained through fluid dynamics simulation and finite element analysis. Finally, a series of optimal adjustments are made for different fluid composition and flow rate combinations to achieve the fluid’s stable laminar flow state. It was determined that when the concentration of sodium alginate in the outer phase was 1 wt% and the concentration of CaCl2 in the inner phase was 0.1 wt%, the gel fiber prepared was in good shape, the flow rate was the most stable, and laminar flow was the most obvious when the flow rate of both was 1 mL/h. This study represents a preliminary achievement in exploring the laminar flow rate and fabricating gel fibers, thus offering significant reference value for investigating microfluidic laminar flow technology.
- 21 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1277
Open AccessEffect of Flow Velocity on Laminar Flow in Microfluidic Chips
Gel fibers prepared based on microfluidic laminar flow technology have important research value in constructing biomimetic scaffolds and tissue engineering. The key point of microfluidic laminar flow technology is to find the appropriate fluid flow rate in the micropipe. In order to explore the influence of flow rate on the laminar flow phenomenon of a microfluidic chip, a microfluidic chip composed of an intermediate main pipe and three surrounding outer pipes are designed, and the chip is prepared by photolithography and the composite molding method. Then, a syringe pump is used to inject different fluids into the microtubing, and the data of fluid motion are obtained through fluid dynamics simulation and finite element analysis. Finally, a series of optimal adjustments are made for different fluid composition and flow rate combinations to achieve the fluid’s stable laminar flow state. It was determined that when the concentration of sodium alginate in the outer phase was 1 wt% and the concentration of CaCl2 in the inner phase was 0.1 wt%, the gel fiber prepared was in good shape, the flow rate was the most stable, and laminar flow was the most obvious when the flow rate of both was 1 mL/h. This study represents a preliminary achievement in exploring the laminar flow rate and fabricating gel fibers, thus offering significant reference value for investigating microfluidic laminar flow technology.
- Open Access
- 31 December 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (1) , 1-15
Tween-80 improves single/coaxial electrospinning of three-layered bioartificial blood vessel
Electrospinning is a promising technique for preparing bioartificial blood vessels. Nanofibers prepared by electrospinning can simulate the structure of extracellular matrix to promote cell adhesion and proliferation. However, thorn-like protrusions can appear as defects on electrospun scaffolds and coaxial electrospun nanofibers often have no clear core/shell structure, which can seriously affect the quality of bioartificial blood vessels. To address these problems, Tween 80 is added to the electrospinning solution, which results in a stable Taylor cone, eliminates the thorn-like protrusions on electrospun bioartificial blood vessels, and reduces interfacial effects due to different core/shell solutions during coaxial electrospinning. Simulations, biomechanical tests, and in vivo studies were performed. The results demonstrate the excellent mechanical properties and biocompatibility of the bioartificial blood vessel. This research provides a useful reference for optimizing the electrospinning process for fabricating bioartificial blood vessels. Graphical Abstract
- 31 December 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (1) , 1-15
Open AccessTween-80 improves single/coaxial electrospinning of three-layered bioartificial blood vessel
Electrospinning is a promising technique for preparing bioartificial blood vessels. Nanofibers prepared by electrospinning can simulate the structure of extracellular matrix to promote cell adhesion and proliferation. However, thorn-like protrusions can appear as defects on electrospun scaffolds and coaxial electrospun nanofibers often have no clear core/shell structure, which can seriously affect the quality of bioartificial blood vessels. To address these problems, Tween 80 is added to the electrospinning solution, which results in a stable Taylor cone, eliminates the thorn-like protrusions on electrospun bioartificial blood vessels, and reduces interfacial effects due to different core/shell solutions during coaxial electrospinning. Simulations, biomechanical tests, and in vivo studies were performed. The results demonstrate the excellent mechanical properties and biocompatibility of the bioartificial blood vessel. This research provides a useful reference for optimizing the electrospinning process for fabricating bioartificial blood vessels. Graphical Abstract