Xiang Li
Xiang Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Boyang Huang
CSG Electric Power Research Institute Co., Ltd., Guangzhou 510663, China
1 shared publication - Dahui Yang
School of Electrical Engineering, Guizhou University, Guiyang 550025, China
1 shared publication - Jing Yang
Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Jing-Liang Zhong
Electric Power Scientific Research Institute of Guizhou Power Grid Guizhou, Guiyang 550000, China
1 shared publication - Qijun Ren
Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication - Qinghui Chen
Guizhou Power Grid Co., Ltd., Guiyang 550002, China
1 shared publication
Latest Publications
- Open Access
- 13 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3599
A Joint Estimation Algorithm for Dual-Mode Channel Fading and Power Line Impulse Noise in Low-Voltage Station Areas
Channel fading and impulse noise in low-voltage station areas severely hinder data acquisition, and effective estimation of dual-mode channel data and state is the critical prerequisite for adaptive transmission. To address the impact of impulse noise on the performance of Orthogonal Frequency Division Multiplexing (OFDM) power line communication systems, this paper proposes a wireless-assisted joint estimation algorithm of channel fading and impulse noise in dual-mode OFDM systems. Firstly, a model of the dual-mode OFDM system combining power line and wireless links is established, and the initial channel estimation is obtained based on Linear Minimum Mean Square Error (LMMSE), the wireless link is used as an aid to provide a relatively reliable initial symbol estimation for the power line link. Then, a two-stage approach for initial impulse noise estimation is proposed: firstly, the possible impulse noise is located based on constructed residuals to form a support set, followed by refinement of the impulse amplitude using Single Measurement Vector Sparse Bayesian Learning (SMV-SBL). Finally, a decision-feedback iterative update is performed to iteratively optimize the symbol detection, channel estimation, and impulse noise estimation processes. Combined with adaptive dual-mode fusion, this approach improves estimation accuracy. Simulation results demonstrate that the proposed algorithm achieves significant improvements in estimation accuracy and bit error rate.
- 13 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3599
Open AccessA Joint Estimation Algorithm for Dual-Mode Channel Fading and Power Line Impulse Noise in Low-Voltage Station Areas
Channel fading and impulse noise in low-voltage station areas severely hinder data acquisition, and effective estimation of dual-mode channel data and state is the critical prerequisite for adaptive transmission. To address the impact of impulse noise on the performance of Orthogonal Frequency Division Multiplexing (OFDM) power line communication systems, this paper proposes a wireless-assisted joint estimation algorithm of channel fading and impulse noise in dual-mode OFDM systems. Firstly, a model of the dual-mode OFDM system combining power line and wireless links is established, and the initial channel estimation is obtained based on Linear Minimum Mean Square Error (LMMSE), the wireless link is used as an aid to provide a relatively reliable initial symbol estimation for the power line link. Then, a two-stage approach for initial impulse noise estimation is proposed: firstly, the possible impulse noise is located based on constructed residuals to form a support set, followed by refinement of the impulse amplitude using Single Measurement Vector Sparse Bayesian Learning (SMV-SBL). Finally, a decision-feedback iterative update is performed to iteratively optimize the symbol detection, channel estimation, and impulse noise estimation processes. Combined with adaptive dual-mode fusion, this approach improves estimation accuracy. Simulation results demonstrate that the proposed algorithm achieves significant improvements in estimation accuracy and bit error rate.
- Open Access
Compressed Air Energy Storage System with Burner and Ejector
The timescale of the energy-release process of an energy storage system has put forward higher requirements with the increasing proportion of new energy power generation in the power grid. In this paper, a new type of compressed-air energy storage system with an ejector and combustor is proposed in order to realize short-timescale and long-timescale energy-release processes under the non-supplementary combustion condition and ejector supplementary combustion condition, respectively. A simulation model of the new system is established in APROS software. The results of this study show that the new system can realize continuous power output when energy storage and energy release operate simultaneously, and especially when the ejector coefficient is 0.8 and burner thermal power is 10 MW, the power-generation time is 12.45 h and the total generated power is 140,052 kW∙h, which are 15.6 and 17.5 times greater those of the short-timescale condition, respectively. In summary, the compressed-air energy storage system with an ejector and combustor that is proposed in this paper can flexibly meet the demands of multiple timescales’ power generation.
Open AccessCompressed Air Energy Storage System with Burner and Ejector
The timescale of the energy-release process of an energy storage system has put forward higher requirements with the increasing proportion of new energy power generation in the power grid. In this paper, a new type of compressed-air energy storage system with an ejector and combustor is proposed in order to realize short-timescale and long-timescale energy-release processes under the non-supplementary combustion condition and ejector supplementary combustion condition, respectively. A simulation model of the new system is established in APROS software. The results of this study show that the new system can realize continuous power output when energy storage and energy release operate simultaneously, and especially when the ejector coefficient is 0.8 and burner thermal power is 10 MW, the power-generation time is 12.45 h and the total generated power is 140,052 kW∙h, which are 15.6 and 17.5 times greater those of the short-timescale condition, respectively. In summary, the compressed-air energy storage system with an ejector and combustor that is proposed in this paper can flexibly meet the demands of multiple timescales’ power generation.