Zhide Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhide Zhou has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Guiyin Li
College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, China
12 shared publications Guiyin Li
College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong, China
10 shared publications- Zhongmin Wang
Guangxi Academy of Sciences
7 shared publications - Jintao Liang
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, China
5 shared publications Xiaojuan Li
School of Materials Science and Engineering, Guilin University of Electronic Technology, Guilin, Guangxi 541004, China
5 shared publicationsJintao Liang
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, China
4 shared publications
Latest Publications
- Open Access
- 28 October 2023
- Published by Atlantis Press SARL
- p. 358-362
Analysis of attribution of liability for ecological damage torts
- 28 October 2023
- Published by Atlantis Press SARL
- p. 358-362
Open AccessAnalysis of attribution of liability for ecological damage torts
- Open Access
- 28 October 2023
- Published by Atlantis Press SARL
- p. 234-240
Copyright Protection of Live Sports Programs
- 28 October 2023
- Published by Atlantis Press SARL
- p. 234-240
Open AccessCopyright Protection of Live Sports Programs
- Open Access
- 28 October 2023
- Published by Atlantis Press SARL
- p. 375-380
Determination of the Subjective Application of Punitive Damages for Patent Infringement
- 28 October 2023
- Published by Atlantis Press SARL
- p. 375-380
Open AccessDetermination of the Subjective Application of Punitive Damages for Patent Infringement
- Open Access
- 28 October 2023
- Published by Atlantis Press SARL
- p. 337-343
Issues and suggestions on the calculation of patent open license fees
- 28 October 2023
- Published by Atlantis Press SARL
- p. 337-343
Open AccessIssues and suggestions on the calculation of patent open license fees
- Open Access
- 8 September 2023
- Published by Atlantis Press SARL
- p. 1827-1832
Analysis on the Standard of Deep Link Behavior Infringement
- 8 September 2023
- Published by Atlantis Press SARL
- p. 1827-1832
Open AccessAnalysis on the Standard of Deep Link Behavior Infringement
- Open Access
H-rGO-Pd NPs Nanozyme Enhanced Silver Deposition Strategy for Electrochemical Detection of Glypican-3
Glypican-3 (GPC3), as an emerging biomarker, has been shown to be beneficial for the early diagnosis and treatment of hepatocellular carcinoma (HCC). In this study, an ultrasensitive electrochemical biosensor for GPC3 detection has been constructed based on the hemin-reduced graphene oxide-palladium nanoparticles (H-rGO-Pd NPs) nanozyme-enhanced silver deposition signal amplification strategy. When GPC3 specifically interacted with GPC3 antibody (GPC3Ab) and GPC3 aptamer (GPC3Apt), an “H-rGO-Pd NPs-GPC3Apt/GPC3/GPC3Ab” sandwich complex was formed with peroxidase-like properties which enhanced H2O2 to reduce the silver (Ag) ions in solution to metallic Ag, resulting in the deposition of silver nanoparticles (Ag NPs) on the surface of the biosensor. The amount of deposited Ag, which was derived from the amount of GPC3, was quantified by the differential pulse voltammetry (DPV) method. Under ideal circumstances, the response value was linearly correlated with GPC3 concentration at 10.0–100.0 μg/mL with R2 of 0.9715. When the GPC3 concentration was in the range from 0.01 to 10.0 μg/mL, the response value was logarithmically linear with the GPC3 concentration with R2 of 0.9941. The limit of detection was 3.30 ng/mL at a signal-to-noise ratio of three and the sensitivity was 1.535 μAμM−1cm−2. Furthermore, the electrochemical biosensor detected the GPC3 level in actual serum samples with good recoveries (103.78–106.52%) and satisfactory relative standard deviations (RSDs) (1.89–8.81%), which confirmed the applicability of the sensor in practical applications. This study provides a new analytical method for measuring the level of GPC3 in the early diagnosis of HCC.
Open AccessH-rGO-Pd NPs Nanozyme Enhanced Silver Deposition Strategy for Electrochemical Detection of Glypican-3
Glypican-3 (GPC3), as an emerging biomarker, has been shown to be beneficial for the early diagnosis and treatment of hepatocellular carcinoma (HCC). In this study, an ultrasensitive electrochemical biosensor for GPC3 detection has been constructed based on the hemin-reduced graphene oxide-palladium nanoparticles (H-rGO-Pd NPs) nanozyme-enhanced silver deposition signal amplification strategy. When GPC3 specifically interacted with GPC3 antibody (GPC3Ab) and GPC3 aptamer (GPC3Apt), an “H-rGO-Pd NPs-GPC3Apt/GPC3/GPC3Ab” sandwich complex was formed with peroxidase-like properties which enhanced H2O2 to reduce the silver (Ag) ions in solution to metallic Ag, resulting in the deposition of silver nanoparticles (Ag NPs) on the surface of the biosensor. The amount of deposited Ag, which was derived from the amount of GPC3, was quantified by the differential pulse voltammetry (DPV) method. Under ideal circumstances, the response value was linearly correlated with GPC3 concentration at 10.0–100.0 μg/mL with R2 of 0.9715. When the GPC3 concentration was in the range from 0.01 to 10.0 μg/mL, the response value was logarithmically linear with the GPC3 concentration with R2 of 0.9941. The limit of detection was 3.30 ng/mL at a signal-to-noise ratio of three and the sensitivity was 1.535 μAμM−1cm−2. Furthermore, the electrochemical biosensor detected the GPC3 level in actual serum samples with good recoveries (103.78–106.52%) and satisfactory relative standard deviations (RSDs) (1.89–8.81%), which confirmed the applicability of the sensor in practical applications. This study provides a new analytical method for measuring the level of GPC3 in the early diagnosis of HCC.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (1) , 111-118
Colorimetric Aptasensor for Sensitive Glypican-3 Detection Based on Hemin-Reduced Oxide Graphene-Platinum@Palladium Nanoparticles With Peroxidase-Like Activity
In recent years, nanozymes-based sensing platforms have been attracted for their excellent performances in practical applications. Glypican-3 (GPC3) has been extensively regarded as a sensitive biomarker for hepatocellular carcinoma (HCC). In this work, the Hemin-reduced oxide graphene-platinum@palladium NPs (H-R-Pt@Pd NPs) with the peroxidase-like activity has been used to construct a facile colorimetric aptasensor for GPC3 detection. GPC3 aptamer (Apt) conjugated to the surface of H-R-Pt@Pd NPs serves as a signal probe, and GPC3 antibody (Ab) uses as a capture probe. In the presence of GPC3, it was recognized by the Ab and the Apt on the H-R-Pt@Pd NPs and initiated the formation of an H-R-Pt@Pd NPs-Apt/GPC3/Ab sandwich structure complex. Taking advantage of the excellent enzymatic catalytic properties, H-R-Pt@Pd NPs can oxidase colorless 3,3’,5,5’-tetramethylbenzidine (TMB) into blue oxTMB with the presence of H 2 O 2 , the absorbance of the system at 652 nm changed consequently, which realize the sensitive colorimetric detection of GPC3. In addition, the catalytic mechanism of H-R-Pt@Pd NPs was confirmed by free radical experiments to be induced by hydroxyl radicals (∙OH). Under optimal conditions, the aptasensor has a linear range of 10.0 to 300.0 ng/mL, and a limit of detection (LOD) of 5.06 ng/mL. Furthermore, the aptasensor is employed to detect GPC3 in human serum samples with the recoveries of 105.94%-116.33% and RSDs of 0.93%-3.08%. Overall, this assay possesses high selectivity and operability, and good sensitivity, indicating the potential for GPC3 detection in the field of clinical HCC diagnosis.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (1) , 111-118
Colorimetric Aptasensor for Sensitive Glypican-3 Detection Based on Hemin-Reduced Oxide Graphene-Platinum@Palladium Nanoparticles With Peroxidase-Like Activity
In recent years, nanozymes-based sensing platforms have been attracted for their excellent performances in practical applications. Glypican-3 (GPC3) has been extensively regarded as a sensitive biomarker for hepatocellular carcinoma (HCC). In this work, the Hemin-reduced oxide graphene-platinum@palladium NPs (H-R-Pt@Pd NPs) with the peroxidase-like activity has been used to construct a facile colorimetric aptasensor for GPC3 detection. GPC3 aptamer (Apt) conjugated to the surface of H-R-Pt@Pd NPs serves as a signal probe, and GPC3 antibody (Ab) uses as a capture probe. In the presence of GPC3, it was recognized by the Ab and the Apt on the H-R-Pt@Pd NPs and initiated the formation of an H-R-Pt@Pd NPs-Apt/GPC3/Ab sandwich structure complex. Taking advantage of the excellent enzymatic catalytic properties, H-R-Pt@Pd NPs can oxidase colorless 3,3’,5,5’-tetramethylbenzidine (TMB) into blue oxTMB with the presence of H 2 O 2 , the absorbance of the system at 652 nm changed consequently, which realize the sensitive colorimetric detection of GPC3. In addition, the catalytic mechanism of H-R-Pt@Pd NPs was confirmed by free radical experiments to be induced by hydroxyl radicals (∙OH). Under optimal conditions, the aptasensor has a linear range of 10.0 to 300.0 ng/mL, and a limit of detection (LOD) of 5.06 ng/mL. Furthermore, the aptasensor is employed to detect GPC3 in human serum samples with the recoveries of 105.94%-116.33% and RSDs of 0.93%-3.08%. Overall, this assay possesses high selectivity and operability, and good sensitivity, indicating the potential for GPC3 detection in the field of clinical HCC diagnosis.
- 9 July 2022
- Published by Elsevier in Bioelectrochemistry
- Vol. 147, 108204
Nanozyme-mediated cascade reaction system for electrochemical detection of 1,5-anhydroglucitol
- 9 July 2022
- Published by Elsevier in Bioelectrochemistry
- Vol. 147, 108204
Nanozyme-mediated cascade reaction system for electrochemical detection of 1,5-anhydroglucitol
- 5 July 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (22) , 6441-6453
A highly sensitive strategy for glypican-3 detection based on aptamer/gold carbon dots/magnetic graphene oxide nanosheets as fluorescent biosensor
Hepatocellular carcinoma (HCC) is the second leading cause of cancer-related deaths in China. Glypican-3 (GPC3) is a specific antigen related to HCC, which is widely used in clinical detection as a reliable marker of HCC. In this paper, a highly sensitive homogeneous apatasensor was designed for GPC3 detection based on fluorescence resonance energy transfer (FRET) where the GPC3 aptamer labelled gold carbon dots (AuCDs-GPC3Apt) are used as a donor and magnetic graphene oxide (Fe3O4/GO) nanosheets are used as an acceptor. A one-step hydrothermal method was used to synthesize AuCDs to provide sufficient fluorescence. The FRET phenomenon exists between AuCDs-GPC3Apt and Fe3O4/GO, which weakens the fluorescence intensity of the whole system. When the target GPC3 is added to the FRET system, the fluorescent AuCDs-GPC3Apt binds to the GPC3 and forms a folded structure, which leads to AuCDs-GPC3Apt separation from Fe3O4/GO nanosheets. The Fe3O4/GO is then magnetically separated so that the fluorescence of free labelled AuCDs-GPC3Apt is restored. Under the optimum conditions, the fluorescence recovery rate is linearly correlated with the concentration of GPC3 (5–100 ng·mL−1) and the detection limit is 3.01 ng·mL−1 (S/N = 3). This strategy shows recoveries from 98.76 to 101.29% in real human serum samples and provides an immediate and effective detection method for the quantification of GPC3 with great potential applications for early diagnosis of HCC. Graphical abstract A sensitive homogeneous FRET-based apatasensor was designed for GPC3 detection where the AuCDs-GPC3Apt is a donor and Fe3O4/GO nanosheets are an acceptor. The GPC3 fluorescent aptasensor combines wider output range with low cost, high specificity, and good anti-interference.
- 5 July 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (22) , 6441-6453
A highly sensitive strategy for glypican-3 detection based on aptamer/gold carbon dots/magnetic graphene oxide nanosheets as fluorescent biosensor
Hepatocellular carcinoma (HCC) is the second leading cause of cancer-related deaths in China. Glypican-3 (GPC3) is a specific antigen related to HCC, which is widely used in clinical detection as a reliable marker of HCC. In this paper, a highly sensitive homogeneous apatasensor was designed for GPC3 detection based on fluorescence resonance energy transfer (FRET) where the GPC3 aptamer labelled gold carbon dots (AuCDs-GPC3Apt) are used as a donor and magnetic graphene oxide (Fe3O4/GO) nanosheets are used as an acceptor. A one-step hydrothermal method was used to synthesize AuCDs to provide sufficient fluorescence. The FRET phenomenon exists between AuCDs-GPC3Apt and Fe3O4/GO, which weakens the fluorescence intensity of the whole system. When the target GPC3 is added to the FRET system, the fluorescent AuCDs-GPC3Apt binds to the GPC3 and forms a folded structure, which leads to AuCDs-GPC3Apt separation from Fe3O4/GO nanosheets. The Fe3O4/GO is then magnetically separated so that the fluorescence of free labelled AuCDs-GPC3Apt is restored. Under the optimum conditions, the fluorescence recovery rate is linearly correlated with the concentration of GPC3 (5–100 ng·mL−1) and the detection limit is 3.01 ng·mL−1 (S/N = 3). This strategy shows recoveries from 98.76 to 101.29% in real human serum samples and provides an immediate and effective detection method for the quantification of GPC3 with great potential applications for early diagnosis of HCC. Graphical abstract A sensitive homogeneous FRET-based apatasensor was designed for GPC3 detection where the AuCDs-GPC3Apt is a donor and Fe3O4/GO nanosheets are an acceptor. The GPC3 fluorescent aptasensor combines wider output range with low cost, high specificity, and good anti-interference.
- 20 June 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1221, 340102
Dual-signal sandwich-type aptasensor based on H-rGO-Mn3O4 nanozymes for ultrasensitive Golgi protein 73 determination
- 20 June 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1221, 340102
Dual-signal sandwich-type aptasensor based on H-rGO-Mn3O4 nanozymes for ultrasensitive Golgi protein 73 determination