XGXiaojie Gao

Xiaojie Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaojie Gao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on Single-Loop FCS-MPC for DC-Based DFIG System

    by Shaomin Yan, Xiaojie Gao, Yonghao Lu, Yue Cui, Yuhan Cai

    Doubly fed induction generator (DFIG) system suffers from complex control structure, slow dynamic response speed and cumbersome parameter design due to its traditional cascaded dual-loop control strategy. A single-loop finite control set model predictive control (SLMPC) is proposed in the paper for DC-based DFIG in DC grid, which simplifies its control structure and parameter design, and enhances system dynamic response. There are three improved aspects. First, the single-loop control structure is proposed to eliminate intermediate link in dual-loop cascaded structure, and enhance system dynamic response. Second, system reduced-order discretization algorithm is proposed by differential and integral discretization method to reduce finite control set model predictive control strategy (FCS-MPC) design difficulty. Third, cost function with nonlinear additional current limiting function is designed to protect system from overcurrent effectively. Finally, the feasibility of proposed strategy is verified by simulations and experiments.


  • Open Access

    Study on Distributed Power-Collection and Cascaded Boosting-Voltage Topology and Strategy for Offshore DC Station

    by Shaomin Yan, Xiaojie Gao, Yue Cui, Hao Zhang, Qingyun Yang

    Different from traditional concentrated power-collection and boosting-voltage (CPCB) topology adopted by HVDC station, this paper adopts a distributed power-collection and cascaded boosting-voltage (DPCB) topology for offshore DC station to collect DC power and boost DC voltage, which consists of multiple cascaded single active bridges (SABs). It has merits of strong DC-voltage boosting ability, low design difficulty and cost, and low system error rate. Three aspects are studied as follows. First, DPCB topology with its circuit equations is deduced step by step, and its operational mechanism is analysed under phase-shifting control method further. Second, PI control strategy is designed based on system small signal model, and system performance is analyzed by Bode diagram. Third, fault tolerance strategy with predicted power ratio is designed to keep DPCB station from breakdown when some SABs and generators are out of order, and enormous power difference occurs due to the factors of wind turbine location and windward. Finally, the feasibility and effectiveness of designed DPCB station with its strategy are verified by experiment results.


  • An Improved FCS-MPC Based on Novel Sector Optimization and Capacitor Charge Balance Algorithm for T-Type 3P-3L Converters

    by Shaomin Yan, Yue Cui, Chengmin Li, Xiaojie Gao, Yuhan Cai

    Conventional finite control set model predictive control (FCS-MPC) suffers from the high computational burden and cumbersome weight factor design, especially for three-phase three-level (3P-3L) converters. In this article, an improved FCS-MPC is proposed for T-type 3P-3L converters to reduce the computational burden, eliminate the weight factor, and improve system performance. Three improvements are as follows. First, a sector optimization method based on effective vector radiation range is proposed to determine the optimal vector for current tracking without vector enumeration, and a combined virtual vector is adopted to supersede the basic vector and avoid affecting neutral-point (NP) potential. Second, a capacitor charge balance algorithm is proposed to determine the optimal vector for NP potential balance without weight factor, which minimizes negative effects on current tracking. Third, a hybrid vector output mode is proposed to give full consideration to current tracking and NP potential balance performance. Finally, the advantages of the proposed MPC are verified in simulation and experiment, where code execution time and current THD are reduced by 16.1 μ s and 1.27%, steady-state current error and capacitor voltage deviation are experimentally reduced by 0.8 A and 0.6 V, and transient dc voltage recovery time and capacitor voltage deviation are experimentally reduced by 2 ms and 0.4 V compared with conventional FCS-MPC.