KKKyung Su Kim

Kyung Su Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kyung Su Kim has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sacrificial‐Template Fabrication of Orientation‐Controlled Porous Titanium Lattices With Bioactive Surfaces

    by Woo‐Youl Maeng, Jung‐Bin Lee, Tae Wan Park, Jaewon Choi, Kyung Su Kim, Yerim Lee, Hyeongu Hwang, Nayoung Lee, Sejin Choi, Minho Kang, et al.

    Porous titanium scaffolds for bone repair require coordinated control of pore architecture, mechanical behavior, and surface bioactivity. Here, we report a sacrificial‐template route based on polymer 3D printing that produces orientation‐controlled porous titanium scaffolds with hierarchical macro‐ and microporosity without direct metal additive manufacturing. Polylactic acid lattices printed by fused deposition modeling are infiltrated with a titanium powder slurry and then subjected to template removal and sintering. The process yields ortho‐grid, tri‐lattice, and quad‐lattice structures with approximately 26% isotropic linear shrinkage, 65%–67% porosity, preserved geometric fidelity, and a relative density of approximately 95% in the sintered strut walls. Uniaxial compression tests reveal architecture‐dependent behavior along the tested loading direction, whereas finite element simulations predict lower directional sensitivity under off‐axis loading as strut‐orientation diversity increases. Micro‐arc oxidation forms a Ca–P‐containing microporous oxide layer and improves cell spreading, proliferation, and alkaline phosphatase activity relative to untreated titanium scaffolds in vitro. In a rat calvarial defect model, uncoated titanium scaffolds achieve bone regeneration comparable to commercial porous tantalum, while micro‐arc oxidation further enhances bone formation. Fabrication of cone augments and other non‐prismatic geometries further demonstrates the adaptability of the approach to complex implant‐relevant structures.

  • Open Access

    The Efficacy of Minimally Invasive Implantable Wireless Electrical Stimulation for the Treatment of Stress Urinary Incontinence in a Rat Model

    by Miho Song, Jong Hyun Yun, Hyun Young Lee, Kyung Su Kim, Jahyun Koo, In Ho Choi, Franklin Don Bien, Jae Heon Kim, Seung Whan Doo

    Purpose: Current therapies using midurethral sling mesh to treat stress urinary incontinence (SUI) are often considered insufficient. This study aims to evaluate the therapeutic efficacies of a minimally invasive implantable wireless electrical stimulator as an alternative treatment of SUI.Methods: SUI was induced in 12 female, 12-week-old Sprague-Dawley rats with a deteriorated urethral sphincter complex by mechanical dilatation of the vagina. Six rats underwent sham operations. Four weeks after inducing SUI, 12 rats with SUI were divided into 2 groups. One group received a transplantation of an implantable wireless electrical stimulator, and the other midline incision and suturing. A total of 4 electrical stimulations were applied for 30 minutes twice weekly for 4 weeks in implantation model. Cystometric parameters including leak point pressure, urethral pressure and electromyography, histological examinations, immunostaining for Masson trichrome stain were measured at 4 weeks after intervention.Results: After SUI induction, mean leak point pressure (LPP) was significantly lower in SUI groups than in controls (25.0±6.9 cm H2O vs. 62.6±4.1 cm H2O, P=0.012). At 4-week postintervention, the +ES group (SUI rat model with stimulation) demonstrated significantly higher LPP than the −ES group (48.8±8.4 cm H2O vs. 26.0±6.6 cm H2O, P=0.002). Urethral pressure showed a nonsignificant upward trend in the +ES group (SUI rat model without stimulation) compared with −ES (20.5±1.4 cm H2O vs. 18.1±1.1 cm H2O, P=0.070). Histology showed improved tissue organization with reduced inflammatory infiltration, and Masson staining demonstrated a trend toward higher collagen density in +ES (bladder: 28.3%±5.2% vs. 32.5%±7.6%, P=0.292; urethra: 44.2%±8.6% vs. 51.7%±8.2%, P=0.153).Conclusions: These results indicate that an implantation of a wireless electrical stimulator can help to improve urethral sphincter function in SUI rat model. Moreover, the minimally invasive wireless electrical strategy may represent a promising therapeutic modality for pelvic floor muscle rehabilitation in the treatment of SUI with potential for clinical translation.


  • Open Access

    3D printed biodegradable hydrogel-based multichannel nerve conduits mimicking peripheral nerve fascicules

    by Woo-Youl Maeng, Yerim Lee, Szu-Han Chen, Kyung Su Kim, Daeun Sung, Wan-Ling Tseng, Gyu-Nam Kim, Young-Hag Koh, Yuan-Yu Hsueh, Jahyun Koo


  • Open Access

    Simultaneous electromechanical monitoring in engineered heart tissues using a mesoscale framework

    by Dominic E. Fullenkamp, Woo-Youl Maeng, Seyong Oh, Haiwen Luan, Kyung Su Kim, Ivana A. Chychula, Jin-Tae Kim, Jae-Young Yoo, Cory W. Holgren, Alexis R. Demonbreun, et al.

    Engineered heart tissues (EHTs) generated from human induced pluripotent stem cell–derived cardiomyocytes (hiPSC-CMs) represent powerful platforms for human cardiac research, especially in drug testing and disease modeling. Here, we report a flexible, three-dimensional electronic framework that enables real-time, spatiotemporal analysis of electrophysiologic and mechanical signals in EHTs under physiological loading conditions for dynamic, noninvasive, longer-term assessments. These electromechanically monitored EHTs support multisite measurements throughout the tissue under baseline conditions and in response to stimuli. Demonstrations include uses in tracking physiological responses to pharmacologically active agents and in capturing electrophysiological characteristics of reentrant arrhythmias. This platform facilitates precise analysis of signal location and conduction velocity in human cardiomyocyte tissues, as the basis for a broad range of advanced cardiovascular studies.


  • Open Access

    Isotropic conductive paste for bioresorbable electronics

    by Kyung Su Kim, Woo-Youl Maeng, Seongchan Kim, Gyubok Lee, Minki Hong, Ga-Been Kim, Jaewon Kim, Sungeun Kim, Seunghun Han, Jaeyoung Yoo, et al.