Diego Rinaldi Pavesi Nicollete
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Diego Rinaldi Pavesi Nicollete has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Bernardo Montesanti Machado de Almeida
Universidade Federal do Paraná, Brazil
3 shared publications - Erika Bergamo Santiago
Research and Development Department, Hilab Campus, Rua José A. Possebom, 800, Curitiba, Parana 81270-185, Brazil
3 shared publications - Marcus Vinícius Mazega Figueredo
Research and Development Department, Hilab Campus, Rua José A. Possebom, 800, Curitiba, Parana 81270-185, Brazil
3 shared publications - Ava Gevaerd
Research and Development Department, Hilab, Hilab Campus, Rua José A. Possebom, 800, Curitiba, 81270‑185, Parana, Brazil.
2 shared publications Beatriz Arruda Valença
Research and Development Department, Hilab, Hilab Campus, Curitiba, Brazil
2 shared publicationsBernardo Montesanti Machado de Almeida
Research and Development Department, Hilab, Hilab Campus, Curitiba, Brazil
2 shared publications
Latest Publications
- Open Access
Utilizing COVID-19 as a Model for Diagnostics Using an Electrochemical Sensor
This paper reports a rapid and sensitive sensor for the detection and quantification of the COVID-19 N-protein (N-PROT) via an electrochemical mechanism. Single-frequency electrochemical impedance spectroscopy was used as a transduction method for real-time measurement of the N-PROT in an immunosensor system based on gold-conjugate-modified carbon screen-printed electrodes (Cov-Ag-SPE). The system presents high selectivity attained through an optimal stimulation signal composed of a 0.0 V DC potential and 10 mV RMS−1 AC signal at 100 Hz over 300 s. The Cov-Ag-SPE showed a log response toward N-PROT detection at concentrations from 1.0 ng mL−1 to 10.0 μg mL−1, with a 0.977 correlation coefficient for the phase (θ) variation. An ML-based approach could be created using some aspects observed from the positive and negative samples; hence, it was possible to classify 252 samples, reaching 83.0, 96.2 and 91.3% sensitivity, specificity, and accuracy, respectively, with confidence intervals (CI) ranging from 73.0 to 100.0%. Because impedance spectroscopy measurements can be performed with low-cost portable instruments, the immunosensor proposed here can be applied in point-of-care diagnostics for mass testing, even in places with limited resources, as an alternative to the common diagnostics methods.
Open AccessUtilizing COVID-19 as a Model for Diagnostics Using an Electrochemical Sensor
This paper reports a rapid and sensitive sensor for the detection and quantification of the COVID-19 N-protein (N-PROT) via an electrochemical mechanism. Single-frequency electrochemical impedance spectroscopy was used as a transduction method for real-time measurement of the N-PROT in an immunosensor system based on gold-conjugate-modified carbon screen-printed electrodes (Cov-Ag-SPE). The system presents high selectivity attained through an optimal stimulation signal composed of a 0.0 V DC potential and 10 mV RMS−1 AC signal at 100 Hz over 300 s. The Cov-Ag-SPE showed a log response toward N-PROT detection at concentrations from 1.0 ng mL−1 to 10.0 μg mL−1, with a 0.977 correlation coefficient for the phase (θ) variation. An ML-based approach could be created using some aspects observed from the positive and negative samples; hence, it was possible to classify 252 samples, reaching 83.0, 96.2 and 91.3% sensitivity, specificity, and accuracy, respectively, with confidence intervals (CI) ranging from 73.0 to 100.0%. Because impedance spectroscopy measurements can be performed with low-cost portable instruments, the immunosensor proposed here can be applied in point-of-care diagnostics for mass testing, even in places with limited resources, as an alternative to the common diagnostics methods.
- Open Access
- 11 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1695
Hilab System Device in an Oncological Hospital: A New Clinical Approach for Point of Care CBC Test, Supported by the Internet of Things and Machine Learning
The complete blood count (CBC) is a highly requested test that is generally restricted to centralized laboratories, which are limited by high cost, being maintenance-demanding, and requiring costly equipment. The Hilab System (HS) is a small, handheld hematological platform that uses microscopy and chromatography techniques, combined with machine learning (ML) and artificial intelligence (AI), to perform a CBC test. This platform uses ML and AI techniques to add higher accuracy and reliability to the results besides allowing for faster reporting. For clinical and flagging capability evaluation of the handheld device, the study analyzed 550 blood samples of patients from a reference institution for oncological diseases. The clinical analysis encompassed the data comparison between the Hilab System and a conventional hematological analyzer (Sysmex XE-2100) for all CBC analytes. The flagging capability study compared the microscopic findings from the Hilab System and the standard blood smear evaluation method. The study also assessed the sample collection source (venous or capillary) influences. The Pearson correlation, Student t-test, Bland–Altman, and Passing–Bablok plot of analytes were calculated and are shown. Data from both methodologies were similar (p > 0.05; r ≥ 0.9 for most parameters) for all CBC analytes and flagging parameters. Venous and capillary samples did not differ statistically (p > 0.05). The study indicates that the Hilab System provides humanized blood collection associated with fast and accurate data, essential features for patient wellbeing and quick physician decision making.
- 11 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1695
Open AccessHilab System Device in an Oncological Hospital: A New Clinical Approach for Point of Care CBC Test, Supported by the Internet of Things and Machine Learning
The complete blood count (CBC) is a highly requested test that is generally restricted to centralized laboratories, which are limited by high cost, being maintenance-demanding, and requiring costly equipment. The Hilab System (HS) is a small, handheld hematological platform that uses microscopy and chromatography techniques, combined with machine learning (ML) and artificial intelligence (AI), to perform a CBC test. This platform uses ML and AI techniques to add higher accuracy and reliability to the results besides allowing for faster reporting. For clinical and flagging capability evaluation of the handheld device, the study analyzed 550 blood samples of patients from a reference institution for oncological diseases. The clinical analysis encompassed the data comparison between the Hilab System and a conventional hematological analyzer (Sysmex XE-2100) for all CBC analytes. The flagging capability study compared the microscopic findings from the Hilab System and the standard blood smear evaluation method. The study also assessed the sample collection source (venous or capillary) influences. The Pearson correlation, Student t-test, Bland–Altman, and Passing–Bablok plot of analytes were calculated and are shown. Data from both methodologies were similar (p > 0.05; r ≥ 0.9 for most parameters) for all CBC analytes and flagging parameters. Venous and capillary samples did not differ statistically (p > 0.05). The study indicates that the Hilab System provides humanized blood collection associated with fast and accurate data, essential features for patient wellbeing and quick physician decision making.
- Open Access
- 6 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (7) , 1355
Clinical Validation of a Colorimetric Loop-Mediated Isothermal Amplification Using a Portable Device for the Rapid Detection of SARS-CoV-2
Quick and reliable mass testing of infected people is an effective tool for the contingency of SARS-CoV-2. During the COVID-19 pandemic, Point-of-Care (POC) tests using Loop-Mediated Isothermal Amplification (LAMP) arose as a useful diagnostic tool. LAMP tests are a robust and fast alternative to Polymerase Chain Reaction (PCR), and their isothermal property allows easy incorporation into POC platforms. The main drawback of using colorimetric LAMP is the reported short-term stability of the pre-mixed reagents, as well as the relatively high rate of false-positive results. Also, low-magnitude amplification can produce a subtle color change, making it difficult to discern a positive reaction. This paper presents Hilab Molecular, a portable device that uses the Internet of Things and Artificial Intelligence to pre-analyze colorimetric data. In addition, we established manufacturing procedures to increase the stability of colorimetric RT-LAMP tests. We show that ready-to-use reactions can be stored for up to 120 days at −20 °C. Furthermore, we validated both the Hilab Molecular device and the Hilab RT-LAMP test for SARS-CoV-2 using 581 patient samples without any purification steps. We achieved a sensitivity of 92.93% and specificity of 99.42% (samples with CT ≤ 30) when compared to RT-qPCR.
- 6 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (7) , 1355
Open AccessClinical Validation of a Colorimetric Loop-Mediated Isothermal Amplification Using a Portable Device for the Rapid Detection of SARS-CoV-2
Quick and reliable mass testing of infected people is an effective tool for the contingency of SARS-CoV-2. During the COVID-19 pandemic, Point-of-Care (POC) tests using Loop-Mediated Isothermal Amplification (LAMP) arose as a useful diagnostic tool. LAMP tests are a robust and fast alternative to Polymerase Chain Reaction (PCR), and their isothermal property allows easy incorporation into POC platforms. The main drawback of using colorimetric LAMP is the reported short-term stability of the pre-mixed reagents, as well as the relatively high rate of false-positive results. Also, low-magnitude amplification can produce a subtle color change, making it difficult to discern a positive reaction. This paper presents Hilab Molecular, a portable device that uses the Internet of Things and Artificial Intelligence to pre-analyze colorimetric data. In addition, we established manufacturing procedures to increase the stability of colorimetric RT-LAMP tests. We show that ready-to-use reactions can be stored for up to 120 days at −20 °C. Furthermore, we validated both the Hilab Molecular device and the Hilab RT-LAMP test for SARS-CoV-2 using 581 patient samples without any purification steps. We achieved a sensitivity of 92.93% and specificity of 99.42% (samples with CT ≤ 30) when compared to RT-qPCR.
- Open Access
- 22 March 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-13
Enhancing a SARS-CoV-2 nucleocapsid antigen test sensitivity with cost efficient strategy through a cotton intermembrane insertion
Lateral flow antigen tests have been widely used in the Covid-19 pandemic, allowing faster diagnostic test results and preventing further viral spread through isolation of infected individuals. Accomplishment of this screening must be performed with tests that show satisfactory sensitivity in order to successfully detect the target protein and avoid false negatives. The aim of this study was to create a lateral flow test that could detect SARS-CoV-2 nucleocapsid protein in low concentrations that were comparable to the limits of detection claimed by existing tests from the market. To do so, several adjustments were necessary during research and development of the prototypes until they were consistent with these criteria. The proposed alternatives of increasing the test line antibody concentration and addition of an intermembrane between the conjugate pad and the nitrocellulose membrane were able to increase the sensitivity four-fold and generate a new rapid test prototype called “lateral flow intermembrane immunoassay test” (LFIIT). This prototype showed an adequate limit of detection (2.0 ng mL−1) while maintaining affordability and simplicity in manufacturing processes.
- 22 March 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-13
Open AccessEnhancing a SARS-CoV-2 nucleocapsid antigen test sensitivity with cost efficient strategy through a cotton intermembrane insertion
Lateral flow antigen tests have been widely used in the Covid-19 pandemic, allowing faster diagnostic test results and preventing further viral spread through isolation of infected individuals. Accomplishment of this screening must be performed with tests that show satisfactory sensitivity in order to successfully detect the target protein and avoid false negatives. The aim of this study was to create a lateral flow test that could detect SARS-CoV-2 nucleocapsid protein in low concentrations that were comparable to the limits of detection claimed by existing tests from the market. To do so, several adjustments were necessary during research and development of the prototypes until they were consistent with these criteria. The proposed alternatives of increasing the test line antibody concentration and addition of an intermembrane between the conjugate pad and the nitrocellulose membrane were able to increase the sensitivity four-fold and generate a new rapid test prototype called “lateral flow intermembrane immunoassay test” (LFIIT). This prototype showed an adequate limit of detection (2.0 ng mL−1) while maintaining affordability and simplicity in manufacturing processes.
- Open Access
- 3 January 2023
- Published by Springer Nature in Research Square
Cost aware strategies for sensitivity enhancement in a SARS-CoV-2 antigen test prototype: insertion of a cotton intermembrane doubles analytical sensitivity
Lateral flow antigen tests have been widely used in the Covid-19 pandemic, allowing faster diagnostic test results and preventing further viral spread through isolation of infected individuals. Accomplishment of this screening must be performed with tests that show satisfactory sensitivity in order to successfully detect the target protein and avoid false negatives. The aim of this study was to create a lateral flow test that could detect SARS-CoV-2 nucleocapsid protein in low concentrations that were comparable to the limits of detection claimed by existing tests from the market. To do so, several adjustments were necessary during research and development of the prototypes until they were consistent with these criteria. The proposed alternatives of increasing the test line antibody concentration and addition of an intermembrane between the conjugate pad and the nitrocellulose membrane were able to increase the sensitivity four-fold and generate a new rapid test prototype called “lateral flow intermembrane immunoassay test” (LFIIT). This prototype showed an adequate limit of detection (2.0 ng mL− 1) while maintaining affordability and simplicity in manufacturing processes.
- 3 January 2023
- Published by Springer Nature in Research Square
Open AccessCost aware strategies for sensitivity enhancement in a SARS-CoV-2 antigen test prototype: insertion of a cotton intermembrane doubles analytical sensitivity
Lateral flow antigen tests have been widely used in the Covid-19 pandemic, allowing faster diagnostic test results and preventing further viral spread through isolation of infected individuals. Accomplishment of this screening must be performed with tests that show satisfactory sensitivity in order to successfully detect the target protein and avoid false negatives. The aim of this study was to create a lateral flow test that could detect SARS-CoV-2 nucleocapsid protein in low concentrations that were comparable to the limits of detection claimed by existing tests from the market. To do so, several adjustments were necessary during research and development of the prototypes until they were consistent with these criteria. The proposed alternatives of increasing the test line antibody concentration and addition of an intermembrane between the conjugate pad and the nitrocellulose membrane were able to increase the sensitivity four-fold and generate a new rapid test prototype called “lateral flow intermembrane immunoassay test” (LFIIT). This prototype showed an adequate limit of detection (2.0 ng mL− 1) while maintaining affordability and simplicity in manufacturing processes.
- Open Access
- 26 March 2021
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais
Validação de kit imunocromatográfico rápido para diagnóstico do HIV 1/2
Estima-se que aproximadamente 38 milhões de pessoas ao redor do mundo são portadoras do vírus da imunodeficiência adquirida (HIV, do inglês human immunodeficiency virus) e que em torno de 2 milhões de...
- 26 March 2021
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais
Open AccessValidação de kit imunocromatográfico rápido para diagnóstico do HIV 1/2
Estima-se que aproximadamente 38 milhões de pessoas ao redor do mundo são portadoras do vírus da imunodeficiência adquirida (HIV, do inglês human immunodeficiency virus) e que em torno de 2 milhões de...