Sarven Akcelyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sarven Akcelyan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Dimitrios G. Lignos
2 shared publications- Dimitrios G. Lignos
École Polytechnique Fédérale de Lausanne
2 shared publications Tsuyoshi Hikino
2 shared publicationsMasayoshi Nakashima
Professor, Disaster Prevention Research Institute (DPRI), Kyoto Univ., Uji, Kyoto 611-0011, Japan
1 shared publication
Latest Publications
- Open Access
Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
This paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story steel space moment-resisting frame building is studied that represents 1970s design practice in North America. Rigorous seismic performance assessment based on ASCE 41 recommendations reveals a high collapse risk for the existing building. The local engineering demand parameters are comprehensively assessed to quantify the impact of seismic retrofit on steel columns and column splices, which are particularly vulnerable due to the time of construction. Multiple retrofit schemes are explored with numerous damping levels and vertical damping distribution methods. The dampers are designed via a recently developed multi-degree-of-freedom performance curves method. A new balanced vertical damping method is proposed to account for the effects of frame inelasticity. This strongly depends on the supplemental damping level, and it determines the effectiveness of the employed vertical damping distribution method. The results indicate that the proposed retrofit strategies can minimize the collapse risk of the tall building. It is shown that the balanced vertical damping distribution method provides the most uniform drift distribution along the building height. Despite the reduction in story drift ratios, the axial force demand in exterior columns remains relatively high in the bottom stories regardless of the seismic retrofit solution. On the other hand, bilinear oil dampers produce relative constant forces despite exhibiting higher velocity demands than expected.
Open AccessSeismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
This paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story steel space moment-resisting frame building is studied that represents 1970s design practice in North America. Rigorous seismic performance assessment based on ASCE 41 recommendations reveals a high collapse risk for the existing building. The local engineering demand parameters are comprehensively assessed to quantify the impact of seismic retrofit on steel columns and column splices, which are particularly vulnerable due to the time of construction. Multiple retrofit schemes are explored with numerous damping levels and vertical damping distribution methods. The dampers are designed via a recently developed multi-degree-of-freedom performance curves method. A new balanced vertical damping method is proposed to account for the effects of frame inelasticity. This strongly depends on the supplemental damping level, and it determines the effectiveness of the employed vertical damping distribution method. The results indicate that the proposed retrofit strategies can minimize the collapse risk of the tall building. It is shown that the balanced vertical damping distribution method provides the most uniform drift distribution along the building height. Despite the reduction in story drift ratios, the axial force demand in exterior columns remains relatively high in the bottom stories regardless of the seismic retrofit solution. On the other hand, bilinear oil dampers produce relative constant forces despite exhibiting higher velocity demands than expected.
- Open Access
- 1 March 2021
- Published by Elsevier in Engineering Structures
- Vol. 230
Rate-dependent model for simulating the hysteretic behavior of low-yield stress buckling-restrained braces under dynamic excitations
- 1 March 2021
- Published by Elsevier in Engineering Structures
- Vol. 230
Open AccessRate-dependent model for simulating the hysteretic behavior of low-yield stress buckling-restrained braces under dynamic excitations
- 1 October 2018
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 113, 488-502
Adaptive numerical method algorithms for nonlinear viscous and bilinear oil damper models subjected to dynamic loading
- 1 October 2018
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 113, 488-502
Adaptive numerical method algorithms for nonlinear viscous and bilinear oil damper models subjected to dynamic loading
- 1 June 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 142 (6)
Evaluation of Simplified and State-of-the-Art Analysis Procedures for Steel Frame Buildings Equipped with Supplemental Damping Devices Based on E-Defense Full-Scale Shake Table Tests
This paper summarizes a number of key findings that affect the use of linear and nonlinear analysis procedures for the seismic evaluation of steel frame buildings with supplemental damping devices and in particular, buckling-restrained braces (BRBs) and nonlinear viscous dampers (NVDs). The assessment is based on a comparison of various engineering demand parameters (EDPs) with experimental data obtained from a series of full-scale shaking table tests of a five-story steel building equipped with BRBs and NVDs. It is shown that: (1) there is no clear advantage between three-dimensional (3D) and two-dimensional (2D) analyses in the prediction of the dynamic behavior of regular plan view steel frame buildings regardless of the damper type; (2) incorporating the brace and nonlinear viscous damper axial flexibility in the analytical model of the test structure with NVDs significantly improves the overall numerical predictions; and (3) the current effective damping ratio recommended by ASCE 41-13 as part of linear static procedures for the evaluation of frame buildings with BRBs or NVDs may not be conservative enough. A new performance-based design tool called performance-spectra (P-Spectra) is able to reliably predict the EDPs of interest. The P-Spectra tool is also able to validate the efficiency of various damper solutions on the dynamic performance of the test structure. It is demonstrated that P-Spectra can be employed to predict estimates of potential residual deformations that traditional linear and nonlinear static procedures cannot.
- 1 June 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 142 (6)
Evaluation of Simplified and State-of-the-Art Analysis Procedures for Steel Frame Buildings Equipped with Supplemental Damping Devices Based on E-Defense Full-Scale Shake Table Tests
This paper summarizes a number of key findings that affect the use of linear and nonlinear analysis procedures for the seismic evaluation of steel frame buildings with supplemental damping devices and in particular, buckling-restrained braces (BRBs) and nonlinear viscous dampers (NVDs). The assessment is based on a comparison of various engineering demand parameters (EDPs) with experimental data obtained from a series of full-scale shaking table tests of a five-story steel building equipped with BRBs and NVDs. It is shown that: (1) there is no clear advantage between three-dimensional (3D) and two-dimensional (2D) analyses in the prediction of the dynamic behavior of regular plan view steel frame buildings regardless of the damper type; (2) incorporating the brace and nonlinear viscous damper axial flexibility in the analytical model of the test structure with NVDs significantly improves the overall numerical predictions; and (3) the current effective damping ratio recommended by ASCE 41-13 as part of linear static procedures for the evaluation of frame buildings with BRBs or NVDs may not be conservative enough. A new performance-based design tool called performance-spectra (P-Spectra) is able to reliably predict the EDPs of interest. The P-Spectra tool is also able to validate the efficiency of various damper solutions on the dynamic performance of the test structure. It is demonstrated that P-Spectra can be employed to predict estimates of potential residual deformations that traditional linear and nonlinear static procedures cannot.