Maria Giulia Ferrari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria Giulia Ferrari has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Dondi
Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Ozzano dell’Emilia, Bologna, Italy
3 shared publications - Antonina De Marco
Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, Ozzano Emilia, 40064 Bologna, Italy
2 shared publications - Chiara Agnoli
Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Ozzano dell’Emilia, Bologna, Italy
2 shared publications - Kateryna Vasylyeva
Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Ozzano dell’Emilia, Bologna, Italy
2 shared publications - Sabrina Fasoli
Department of Veterinary Medical Sciences, Alma Mater Studiorum - University of Bologna, Via Tolara di Sopra 50, 40064, Ozzano dell'Emilia, Italy
2 shared publications Alessio Bonaldo
Department of Veterinary Medical Sciences, University of Bologna, Via Tolara di Sopra 50, 40064, Ozzano Emilia, Bologna, Italy
1 shared publication
Latest Publications
- 4 September 2026
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 38 (6) , 1182-1201
Analytical validation of the Mindray BC-75R Vet hematology analyzer and comparison with the Siemens Advia 2120i for application in dogs and cats
The BC-75R Vet (Mindray Animal Medical) is a multi-species hematology analyzer that uses electrical impedance and SF-Cube technology (combining laser scatter, fluorescence, and 3-dimensional analysis) for CBC and reticulocyte analysis. We evaluated its analytical performance and compared it with the Advia 2120i (Siemens), a widely used analyzer in veterinary clinical pathology. CBCs were performed on EDTA-anticoagulated blood samples from 411 dogs and 225 cats submitted for routine testing. Analytical precision, linearity, carryover, and total observed error (TE obs ) were assessed according to ASVCP guidelines. We used a 2120i as the reference method and manual differential counts for WBC evaluation. RIs were calculated from 131 healthy dogs and 53 cats. The BC-75R Vet fulfilled the ASVCP requirements for repeatability (CVs < 5% for most variables) and linearity ( r > 0.97), with negligible carryover. TE obs values were within ASVCP allowable error limits, except for WBC types in QC material, which remained acceptable for in-clinic use. Agreement with the 2120i was acceptable for most RBC-related variables; however, systematic and proportional errors were found for mean corpuscular hemoglobin concentration (MCHC) in both species, and a systematic error for mean corpuscular volume (MCV) was found in dogs. Agreement for WBC and platelet counts was generally good, although discrepancies were noted for monocyte and mean platelet volume in both species. These differences likely reflect methodologic differences and known challenges in feline hematology. Despite these limitations, the BC-75R Vet met ASVCP standards and appears suitable for routine testing in dogs and cats. Manual smear review remains essential in selected cases.
- 4 September 2026
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 38 (6) , 1182-1201
Analytical validation of the Mindray BC-75R Vet hematology analyzer and comparison with the Siemens Advia 2120i for application in dogs and cats
The BC-75R Vet (Mindray Animal Medical) is a multi-species hematology analyzer that uses electrical impedance and SF-Cube technology (combining laser scatter, fluorescence, and 3-dimensional analysis) for CBC and reticulocyte analysis. We evaluated its analytical performance and compared it with the Advia 2120i (Siemens), a widely used analyzer in veterinary clinical pathology. CBCs were performed on EDTA-anticoagulated blood samples from 411 dogs and 225 cats submitted for routine testing. Analytical precision, linearity, carryover, and total observed error (TE obs ) were assessed according to ASVCP guidelines. We used a 2120i as the reference method and manual differential counts for WBC evaluation. RIs were calculated from 131 healthy dogs and 53 cats. The BC-75R Vet fulfilled the ASVCP requirements for repeatability (CVs < 5% for most variables) and linearity ( r > 0.97), with negligible carryover. TE obs values were within ASVCP allowable error limits, except for WBC types in QC material, which remained acceptable for in-clinic use. Agreement with the 2120i was acceptable for most RBC-related variables; however, systematic and proportional errors were found for mean corpuscular hemoglobin concentration (MCHC) in both species, and a systematic error for mean corpuscular volume (MCV) was found in dogs. Agreement for WBC and platelet counts was generally good, although discrepancies were noted for monocyte and mean platelet volume in both species. These differences likely reflect methodologic differences and known challenges in feline hematology. Despite these limitations, the BC-75R Vet met ASVCP standards and appears suitable for routine testing in dogs and cats. Manual smear review remains essential in selected cases.
- Open Access
Approach for Hemolymph Collection and Biochemical Profiling of Invasive Callinectes sapidus: Methodology and Physiological Assessment
The blue crab, Callinectes sapidus, is an invasive species in the Mediterranean Sea, where it has gained particular attention since 2023 due to its negative ecological and economic impacts. This study aimed to define a standardized method for hemolymph collection and biochemical analysis in male blue crabs from the northern Adriatic Sea, providing data on their physiological status. Hemolymph was collected following a standardized protocol. Preliminary validation tests showed good recovery, stability and linearity results for biochemical analytes, showing no significant analytical interference due to hemolymph pigmentation. Then, key biochemical variables, including glucose, calcium, magnesium, triglyceride, urea, uric acid, aspartate transaminase, gamma-glutamyl transferase, phosphate, potassium, sodium, chloride and total protein, were analyzed. The results revealed considerable variability in the biochemical profiles of the sampled individuals, consistent with the natural heterogeneity expected in a field-collected, mixed-molt cohort, while overall indicating a generally consistent euryhalinity, a good physiological status. The study underscores the importance of standardized protocols for hemolymph analysis in blue crab, contributing to the understanding of its physiology and invasive success.
Open AccessApproach for Hemolymph Collection and Biochemical Profiling of Invasive Callinectes sapidus: Methodology and Physiological Assessment
The blue crab, Callinectes sapidus, is an invasive species in the Mediterranean Sea, where it has gained particular attention since 2023 due to its negative ecological and economic impacts. This study aimed to define a standardized method for hemolymph collection and biochemical analysis in male blue crabs from the northern Adriatic Sea, providing data on their physiological status. Hemolymph was collected following a standardized protocol. Preliminary validation tests showed good recovery, stability and linearity results for biochemical analytes, showing no significant analytical interference due to hemolymph pigmentation. Then, key biochemical variables, including glucose, calcium, magnesium, triglyceride, urea, uric acid, aspartate transaminase, gamma-glutamyl transferase, phosphate, potassium, sodium, chloride and total protein, were analyzed. The results revealed considerable variability in the biochemical profiles of the sampled individuals, consistent with the natural heterogeneity expected in a field-collected, mixed-molt cohort, while overall indicating a generally consistent euryhalinity, a good physiological status. The study underscores the importance of standardized protocols for hemolymph analysis in blue crab, contributing to the understanding of its physiology and invasive success.
- 11 August 2025
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 37 (6) , 862-872
Spurious increase in automated optical platelet counts associated with lipemia in dogs
Spurious platelet counts (PLTCs) associated with lipemia are documented in humans and rarely in dogs. We retrospectively evaluated CBCs of dogs admitted to a veterinary hospital to assess the interference of lipemia with the automated PLTC (A-PLTC) measured by an optical method (Advia 2120i; Siemens). The severity of lipemia was used to group CBC results into 2 groups: severe lipemia (SL) and non-severe lipemia (NSL). Samples with abnormalities other than lipemia, potentially associated with a spurious increase in PLTC, were excluded. In the SL group, a manual PLTC (M-PLTC) was performed, and its difference with A-PLTC (ΔAPLT-MPLT) was calculated. Platelet scatter plots, concentration of triglycerides and cholesterol, diseases, and therapies were evaluated. We selected 9,535 samples, 173 (1.9%) in the SL group and 9,362 in the NSL group. The A-PLTC was significantly increased in the SL group (median: 399 × 10 9 /L; range: 11–1,900 × 10 9 /L) compared to the NSL group (median: 300 × 10 9 /L, range: 1–2,250 × 10 9 /L; p < 0.0001). In the SL group, A-PLTC was significantly increased compared to M-PLTC (median: 356 × 10 9 /L, range: 24–1,170 × 10 9 /L, p = 0.01; median: ΔAPLT-MPLT +25 × 10 9 /L, range: –190 to 1,700 × 10 9 /L), and the triglyceride concentration (median: 8.71 mmol/L; range: 0.55–152 mmol/L) was significantly associated with ΔAPLT-MPLT ( r 2 = 0.05; p = 0.004). Dogs with pancreatitis had significantly increased ΔAPLT-MPLT (median: +624 × 10 9 /L; range: 62–1,700 × 10 9 /L) compared to other disease categories ( p = 0.01). Severe lipemia may be associated with a spurious A-PLTC increase in dogs; careful evaluation of platelet scatter plots and visual inspection of serum are recommended. Manual estimation is required to correct the A-PLTC when this artifact is detected.
- 11 August 2025
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 37 (6) , 862-872
Spurious increase in automated optical platelet counts associated with lipemia in dogs
Spurious platelet counts (PLTCs) associated with lipemia are documented in humans and rarely in dogs. We retrospectively evaluated CBCs of dogs admitted to a veterinary hospital to assess the interference of lipemia with the automated PLTC (A-PLTC) measured by an optical method (Advia 2120i; Siemens). The severity of lipemia was used to group CBC results into 2 groups: severe lipemia (SL) and non-severe lipemia (NSL). Samples with abnormalities other than lipemia, potentially associated with a spurious increase in PLTC, were excluded. In the SL group, a manual PLTC (M-PLTC) was performed, and its difference with A-PLTC (ΔAPLT-MPLT) was calculated. Platelet scatter plots, concentration of triglycerides and cholesterol, diseases, and therapies were evaluated. We selected 9,535 samples, 173 (1.9%) in the SL group and 9,362 in the NSL group. The A-PLTC was significantly increased in the SL group (median: 399 × 10 9 /L; range: 11–1,900 × 10 9 /L) compared to the NSL group (median: 300 × 10 9 /L, range: 1–2,250 × 10 9 /L; p < 0.0001). In the SL group, A-PLTC was significantly increased compared to M-PLTC (median: 356 × 10 9 /L, range: 24–1,170 × 10 9 /L, p = 0.01; median: ΔAPLT-MPLT +25 × 10 9 /L, range: –190 to 1,700 × 10 9 /L), and the triglyceride concentration (median: 8.71 mmol/L; range: 0.55–152 mmol/L) was significantly associated with ΔAPLT-MPLT ( r 2 = 0.05; p = 0.004). Dogs with pancreatitis had significantly increased ΔAPLT-MPLT (median: +624 × 10 9 /L; range: 62–1,700 × 10 9 /L) compared to other disease categories ( p = 0.01). Severe lipemia may be associated with a spurious A-PLTC increase in dogs; careful evaluation of platelet scatter plots and visual inspection of serum are recommended. Manual estimation is required to correct the A-PLTC when this artifact is detected.
- 4 January 2023
- Published by Elsevier in Fish & Shellfish Immunology
- Vol. 133, 108518
Prolonged heat waves reduce the condition index and alter the molecular parameters in the pacific oyster Crassostrea gigas
- 4 January 2023
- Published by Elsevier in Fish & Shellfish Immunology
- Vol. 133, 108518
Prolonged heat waves reduce the condition index and alter the molecular parameters in the pacific oyster Crassostrea gigas