Konstantinos Kafchitsas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Konstantinos Kafchitsas has a total of 180 co-authors. Here are the top co-authors by number of shared publications:
Charalampos Matzaroglou
3 shared publicationsAthanasios Karageorgos
2 shared publications- Evangelos Christodoulou
Asklepios Klinik Lindenlohe, Schwandorf, Germany
2 shared publications - John Amen
Division of Paediatric Orthopaedics, Department of Orthopaedic Surgery, Ain Shams University, Cairo, Egypt
2 shared publications Michail Kokkinakis
Department of Paediatric Orthopaedic Surgery, Evelina London Children’s Hospital, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
2 shared publicationsOliver Perkins
Department of Paediatric Orthopaedic Surgery, Evelina London Children’s Hospital, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
2 shared publications
Latest Publications
- Open Access
- 16 June 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (6) , 61
Return to Play After Total Hip Arthroplasty: What Do Instrumented Hip Implants Teach Us? A Scoping Review
Background: Return to play (RTP) after total hip arthroplasty (THA) is increasingly expected by younger and more physically active patients. Current activity recommendations remain heterogeneous and are largely derived from expert opinion and indirect biomechanical modelling approaches, rather than direct in vivo biomechanical evidence. The aim of this article is to systematically map and synthesize the evidence from instrumented hip implant studies and to clarify how direct in vivo telemetry data can inform RTP counselling after THA. Methods: A scoping review was conducted according to a predefined Open Science Framework protocol and reported following PRISMA-ScR guidelines. MEDLINE (PubMed) and Scopus were searched from inception. Peer-reviewed clinical studies reporting direct in vivo biomechanical measurements obtained from instrumented hip implants were included. Conference proceedings, technical notes, reviews, and in vitro or computational-only studies were excluded. Data were extracted and synthesized descriptively according to activity domain, biomechanical variables, and implant technology. Results: Fifty studies met the inclusion criteria. Early investigations established feasibility and evolved from wired strain-gauge systems to fully implantable telemetric prostheses capable of measuring three-dimensional forces, moments, and friction-related parameters. Across cohorts, level walking consistently produced peak hip contact forces of approximately 2–3 times body weight, serving as a clinically meaningful reference loading envelope. Several recreational activities—including cycling, aquatic exercise, Nordic walking, and most gym-machine exercises—generally remained within or close to this range when performed with controlled technique. In contrast, certain rehabilitation tasks, forward-bent postures, lifting maneuvers, and perturbation events generated loads equal to or exceeding those observed during walking. Importantly, frictional moments and load direction showed substantial variability and may be more relevant to implant fixation than peak force magnitude alone. Conclusions: Instrumented hip implants provide objective biomechanical benchmarks that support principle-based and individualized RTP counselling, grounded in directly measured mechanical exposure rather than sport classification alone.
- 16 June 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (6) , 61
Open AccessReturn to Play After Total Hip Arthroplasty: What Do Instrumented Hip Implants Teach Us? A Scoping Review
Background: Return to play (RTP) after total hip arthroplasty (THA) is increasingly expected by younger and more physically active patients. Current activity recommendations remain heterogeneous and are largely derived from expert opinion and indirect biomechanical modelling approaches, rather than direct in vivo biomechanical evidence. The aim of this article is to systematically map and synthesize the evidence from instrumented hip implant studies and to clarify how direct in vivo telemetry data can inform RTP counselling after THA. Methods: A scoping review was conducted according to a predefined Open Science Framework protocol and reported following PRISMA-ScR guidelines. MEDLINE (PubMed) and Scopus were searched from inception. Peer-reviewed clinical studies reporting direct in vivo biomechanical measurements obtained from instrumented hip implants were included. Conference proceedings, technical notes, reviews, and in vitro or computational-only studies were excluded. Data were extracted and synthesized descriptively according to activity domain, biomechanical variables, and implant technology. Results: Fifty studies met the inclusion criteria. Early investigations established feasibility and evolved from wired strain-gauge systems to fully implantable telemetric prostheses capable of measuring three-dimensional forces, moments, and friction-related parameters. Across cohorts, level walking consistently produced peak hip contact forces of approximately 2–3 times body weight, serving as a clinically meaningful reference loading envelope. Several recreational activities—including cycling, aquatic exercise, Nordic walking, and most gym-machine exercises—generally remained within or close to this range when performed with controlled technique. In contrast, certain rehabilitation tasks, forward-bent postures, lifting maneuvers, and perturbation events generated loads equal to or exceeding those observed during walking. Importantly, frictional moments and load direction showed substantial variability and may be more relevant to implant fixation than peak force magnitude alone. Conclusions: Instrumented hip implants provide objective biomechanical benchmarks that support principle-based and individualized RTP counselling, grounded in directly measured mechanical exposure rather than sport classification alone.
- Open Access
- 14 May 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
The benefit of cement-augmented pedicle screws for revision surgery in osteoporotic bone – a cadaveric study
Purpose: Increasing numbers of spine surgery cases and an aging society led to challenges during revision surgery with osteoporotic bone. Safe and stable operative techniques are required. Methods: In this ex vivo study, human lumbar vertebrae were prepared and then screened for assessing bone density. Eighteen donors (65 vertebrae) with osteoporotic conditions were included. Primary dorsal instrumentation was performed using either standard pedicle screws (6.35 mm diameter; Group A, n = 50) or vertebroplasty screws (VT, 6.35 mm; Group B, n = 15). This was followed by a standardized pull-out test cycle, after which the vertebrae of group A exhibited pedicle perforations replicating revision conditions. Subsequently, 50 vertebrae from Group A were reassigned to simulate revision conditions and divided into two subgroups (n = 25 each): Group A1 received conventional pedicle screws with an increased diameter (7.5 mm), while Group A2 was treated with cement-augmented pedicle screws (VT, 6.35 mm). A second pull-out test was performed, and statistical analysis was conducted. Results: The specimens with conventional screws had a lower mean pull-out strength compared to primarily cement-augmented screws during the first pull-out cycle 662.8 ± 365.1 N vs. 1066.1 ± 213.7 N. In the revision model, cement-augmented screws (Group A2) demonstrated a significant higher median pull-out strength compared to larger-diameter conventional screws (Group A1) (687.5 N [IQR: 448.8–1137.5 N]; vs. 486.5 N [IQR: 338.8–605.0 N]). Conclusion: In this ex vivo revision model of osteoporotic bone, increasing screw diameter alone resulted in reduced pull-out strength compared to primary instrumentation, whereas cement-augmented pedicle screws consistently demonstrated superior fixation in both test cycles. These findings highlight the limited effectiveness of increasing screw diameter under revision conditions and support cement augmentation as a biomechanically advantageous strategy in osteoporotic bone, while clinical validation remains necessary.
- 14 May 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Open AccessThe benefit of cement-augmented pedicle screws for revision surgery in osteoporotic bone – a cadaveric study
Purpose: Increasing numbers of spine surgery cases and an aging society led to challenges during revision surgery with osteoporotic bone. Safe and stable operative techniques are required. Methods: In this ex vivo study, human lumbar vertebrae were prepared and then screened for assessing bone density. Eighteen donors (65 vertebrae) with osteoporotic conditions were included. Primary dorsal instrumentation was performed using either standard pedicle screws (6.35 mm diameter; Group A, n = 50) or vertebroplasty screws (VT, 6.35 mm; Group B, n = 15). This was followed by a standardized pull-out test cycle, after which the vertebrae of group A exhibited pedicle perforations replicating revision conditions. Subsequently, 50 vertebrae from Group A were reassigned to simulate revision conditions and divided into two subgroups (n = 25 each): Group A1 received conventional pedicle screws with an increased diameter (7.5 mm), while Group A2 was treated with cement-augmented pedicle screws (VT, 6.35 mm). A second pull-out test was performed, and statistical analysis was conducted. Results: The specimens with conventional screws had a lower mean pull-out strength compared to primarily cement-augmented screws during the first pull-out cycle 662.8 ± 365.1 N vs. 1066.1 ± 213.7 N. In the revision model, cement-augmented screws (Group A2) demonstrated a significant higher median pull-out strength compared to larger-diameter conventional screws (Group A1) (687.5 N [IQR: 448.8–1137.5 N]; vs. 486.5 N [IQR: 338.8–605.0 N]). Conclusion: In this ex vivo revision model of osteoporotic bone, increasing screw diameter alone resulted in reduced pull-out strength compared to primary instrumentation, whereas cement-augmented pedicle screws consistently demonstrated superior fixation in both test cycles. These findings highlight the limited effectiveness of increasing screw diameter under revision conditions and support cement augmentation as a biomechanically advantageous strategy in osteoporotic bone, while clinical validation remains necessary.
- Open Access
- 15 April 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 7 (4) , 540-548
HipScreen: a valid mobile app to measure hip migration in children with cerebral palsy in the community setting
Aims: The Reimers migration percentage (MP) is the gold-standard radiological parameter used to aid decision-making regarding surgical management of hip displacement in cerebral palsy (CP). Accurate measurement is important to risk stratify patients and allow timely onward referral from community teams to paediatric orthopaedic services. We performed a study to determine whether experts and novices could use a free smartphone app (HipScreen (HS) app) as a valid method for measuring MP in CP. Methods: Using the HS app, two groups measured MP in 20 pelvis radiographs (40 hips) at weeks 0 and 2. The ‘inexperienced’ group included four community physiotherapists with no CP experience. The ‘experienced’ group included four community physiotherapists and two paediatricians with CP experience. All participants watched the tutorial videos on the HS app website. HS app measurements were then compared with gold-standard picture archiving and communication system (PACS) measurements conducted by a senior paediatric orthopaedic surgeon. Modified Pearson correlation (r) was used to determine inter-rater reliability between HS app and PACS measurements. Intraclass correlation coefficient (ICC) was then used to assess intrarater reliability. The mean absolute deviation (MAD) was calculated to compare raters with the gold standard. Results: HS app measurements in the experienced and inexperienced groups showed highly significant correlation with the gold-standard measurements (p < 0.001). There were no significant differences between intra- or inter-group measurements at weeks 0 and 2 with r > 0.86 and p < 0.001. Both inter- and intra-rater reliability were excellent with ICC > 0.9. There was no statistically significant difference in the MAD within individual measurements and compared with the gold standard. Conclusion: The HS app is accurate in measuring MP in CP when used by non-specialists and specialists. Non-specialists do not require additional supplementary training. These findings suggest app efficacy and safety in regional and national hip surveillance programmes for children with CP. Cite this article: Bone Jt Open 2026;7(4):540–548.
- 15 April 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 7 (4) , 540-548
Open AccessHipScreen: a valid mobile app to measure hip migration in children with cerebral palsy in the community setting
Aims: The Reimers migration percentage (MP) is the gold-standard radiological parameter used to aid decision-making regarding surgical management of hip displacement in cerebral palsy (CP). Accurate measurement is important to risk stratify patients and allow timely onward referral from community teams to paediatric orthopaedic services. We performed a study to determine whether experts and novices could use a free smartphone app (HipScreen (HS) app) as a valid method for measuring MP in CP. Methods: Using the HS app, two groups measured MP in 20 pelvis radiographs (40 hips) at weeks 0 and 2. The ‘inexperienced’ group included four community physiotherapists with no CP experience. The ‘experienced’ group included four community physiotherapists and two paediatricians with CP experience. All participants watched the tutorial videos on the HS app website. HS app measurements were then compared with gold-standard picture archiving and communication system (PACS) measurements conducted by a senior paediatric orthopaedic surgeon. Modified Pearson correlation (r) was used to determine inter-rater reliability between HS app and PACS measurements. Intraclass correlation coefficient (ICC) was then used to assess intrarater reliability. The mean absolute deviation (MAD) was calculated to compare raters with the gold standard. Results: HS app measurements in the experienced and inexperienced groups showed highly significant correlation with the gold-standard measurements (p < 0.001). There were no significant differences between intra- or inter-group measurements at weeks 0 and 2 with r > 0.86 and p < 0.001. Both inter- and intra-rater reliability were excellent with ICC > 0.9. There was no statistically significant difference in the MAD within individual measurements and compared with the gold standard. Conclusion: The HS app is accurate in measuring MP in CP when used by non-specialists and specialists. Non-specialists do not require additional supplementary training. These findings suggest app efficacy and safety in regional and national hip surveillance programmes for children with CP. Cite this article: Bone Jt Open 2026;7(4):540–548.
- Open Access
- 1 January 2026
- Published by Wiley in Case Reports in Neurological Medicine
- Vol. 2026 (1)
Migrated Sacral Facet Joint Cyst Mimicking a Tarlov Cyst: A Case Report
We report the case of a 78‐year‐old male presenting with debilitating left‐sided S1 radicular pain, associated with a positive Lasègue sign and numbness in the S1 dermatome. The patient exhibited mild motor deficits, but his pain was severe enough to impair standing and ambulation. Magnetic resonance imaging (MRI) revealed a cystic lesion at the S1 level; however, the exact etiology remained unclear—differential diagnoses included a Tarlov cyst or a facet joint cyst. No other spinal comorbidities were noticed. Initial conservative management, including intravenous analgesics and C‐arm–guided S1 nerve root blocks, failed to provide relief. Due to persistent symptoms, surgical exploration was undertaken. Intraoperatively, a facet joint cyst was identified and successfully excised. Postoperative recovery was uneventful, and the patient reported significant pain relief and functional improvement. This case highlights an unusual presentation of a facet joint cyst located at the sacral level without a visible connection to the facet joint, raising diagnostic challenges on imaging.
- 1 January 2026
- Published by Wiley in Case Reports in Neurological Medicine
- Vol. 2026 (1)
Open AccessMigrated Sacral Facet Joint Cyst Mimicking a Tarlov Cyst: A Case Report
We report the case of a 78‐year‐old male presenting with debilitating left‐sided S1 radicular pain, associated with a positive Lasègue sign and numbness in the S1 dermatome. The patient exhibited mild motor deficits, but his pain was severe enough to impair standing and ambulation. Magnetic resonance imaging (MRI) revealed a cystic lesion at the S1 level; however, the exact etiology remained unclear—differential diagnoses included a Tarlov cyst or a facet joint cyst. No other spinal comorbidities were noticed. Initial conservative management, including intravenous analgesics and C‐arm–guided S1 nerve root blocks, failed to provide relief. Due to persistent symptoms, surgical exploration was undertaken. Intraoperatively, a facet joint cyst was identified and successfully excised. Postoperative recovery was uneventful, and the patient reported significant pain relief and functional improvement. This case highlights an unusual presentation of a facet joint cyst located at the sacral level without a visible connection to the facet joint, raising diagnostic challenges on imaging.
- Open Access
- 17 September 2023
- Published by Elsevier in The Spine Journal
- Vol. 24 (1) , 125-131
Does the interfacing angle between pedicle screws and support rods affect clinical outcomes after posterior thoracolumbar fusion? A retrospective clinical study
- 17 September 2023
- Published by Elsevier in The Spine Journal
- Vol. 24 (1) , 125-131
Open AccessDoes the interfacing angle between pedicle screws and support rods affect clinical outcomes after posterior thoracolumbar fusion? A retrospective clinical study
- Open Access
- 22 May 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (5) , 363-369
Measuring hip migration percentage in cerebral palsy using the HipScreen app
Aims: Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app).Methods: A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s correlation coefficient (r) was used to compare PACS measurements and all HS app measurements and assess validity. Intraclass correlation coefficient (ICC) was used to assess intra- and inter-rater reliability.Results: All HS app measurements (from 5 raters at week 0 and week 2 and PACS rater) showed highly significant correlation with the PACS measurements (p < 0.001). Pearson’s correlation coefficient (r) was constantly over 0.9, suggesting high validity. Correlation of all HS app measures from different raters to each other was significant with r > 0.874 and p < 0.001, which also confirms high validity. Both inter- and intra-rater reliability were excellent with ICC > 0.9. In a 95% confidence interval for repeated measurements, the deviation of each specific measurement was less than 4% MP for single measurer and 5% for different measurers.Conclusion: The HS app provides a valid method to measure hip MP in CP, with excellent inter- and intra-rater reliability across different medical and allied health specialties. This can be used in hip surveillance programmes by interdisciplinary measurers.Cite this article: Bone Jt Open 2023;4(5):363–369.
- 22 May 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (5) , 363-369
Open AccessMeasuring hip migration percentage in cerebral palsy using the HipScreen app
Aims: Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app).Methods: A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s correlation coefficient (r) was used to compare PACS measurements and all HS app measurements and assess validity. Intraclass correlation coefficient (ICC) was used to assess intra- and inter-rater reliability.Results: All HS app measurements (from 5 raters at week 0 and week 2 and PACS rater) showed highly significant correlation with the PACS measurements (p < 0.001). Pearson’s correlation coefficient (r) was constantly over 0.9, suggesting high validity. Correlation of all HS app measures from different raters to each other was significant with r > 0.874 and p < 0.001, which also confirms high validity. Both inter- and intra-rater reliability were excellent with ICC > 0.9. In a 95% confidence interval for repeated measurements, the deviation of each specific measurement was less than 4% MP for single measurer and 5% for different measurers.Conclusion: The HS app provides a valid method to measure hip MP in CP, with excellent inter- and intra-rater reliability across different medical and allied health specialties. This can be used in hip surveillance programmes by interdisciplinary measurers.Cite this article: Bone Jt Open 2023;4(5):363–369.
- Open Access
- 2 April 2023
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 17 (3) , 268-275
Bony hip reconstruction for displaced hips in patients with cerebral palsy: Is postoperative immobilization indicated?
Purpose: Decisions for postoperative immobilization after bony hip reconstructive surgery in cerebral palsy are controversial in current practice. The aim of this study was to check if choosing not to use any kind of postoperative immobilization is a safe practice. Methods: A retrospective cohort study was conducted in a pediatric orthopedic tertiary referral center. The study included 148 patients (228 hips) with cerebral palsy, who had bony hip surgery. Medical records were reviewed for incidence of complications, methods of pain control, and length of hospital stay. Three radiographic measures (neck-shaft angle, Reimers migration index, and acetabular index) were performed on preoperative and postoperative X-rays. X-rays were also checked for mechanical failure of implant, recurrent dislocation/subluxation, and fractures in the first 6 months postoperatively. Results: In total, 94 (64%) were male and 54 (36%) were female. Seventy-seven (52%) were Gross Motor Function Classification System V, mean age at surgery was 8.6 years (2.5–18.4 years). Length of hospital stay was 6.25 days (SD 4.64 days). Medical complications that may have prolonged hospital stay occurred in 41 patients (27.7%). Radiological measurements showed significant improvement postoperatively ( p = 0.001). Seven patients (4.7%) had another surgery in first 6 months (three for recurrent dislocation/subluxation, three for implant failure, and one for ipsilateral femur fracture). Conclusion: Avoiding postoperative immobilization following bony hip surgery in cerebral palsy is a safe practice and associated with reduced rate of medical and mechanical problems compared to the current literature. This approach should be utilized with optimal pain and tone management.
- 2 April 2023
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 17 (3) , 268-275
Open AccessBony hip reconstruction for displaced hips in patients with cerebral palsy: Is postoperative immobilization indicated?
Purpose: Decisions for postoperative immobilization after bony hip reconstructive surgery in cerebral palsy are controversial in current practice. The aim of this study was to check if choosing not to use any kind of postoperative immobilization is a safe practice. Methods: A retrospective cohort study was conducted in a pediatric orthopedic tertiary referral center. The study included 148 patients (228 hips) with cerebral palsy, who had bony hip surgery. Medical records were reviewed for incidence of complications, methods of pain control, and length of hospital stay. Three radiographic measures (neck-shaft angle, Reimers migration index, and acetabular index) were performed on preoperative and postoperative X-rays. X-rays were also checked for mechanical failure of implant, recurrent dislocation/subluxation, and fractures in the first 6 months postoperatively. Results: In total, 94 (64%) were male and 54 (36%) were female. Seventy-seven (52%) were Gross Motor Function Classification System V, mean age at surgery was 8.6 years (2.5–18.4 years). Length of hospital stay was 6.25 days (SD 4.64 days). Medical complications that may have prolonged hospital stay occurred in 41 patients (27.7%). Radiological measurements showed significant improvement postoperatively ( p = 0.001). Seven patients (4.7%) had another surgery in first 6 months (three for recurrent dislocation/subluxation, three for implant failure, and one for ipsilateral femur fracture). Conclusion: Avoiding postoperative immobilization following bony hip surgery in cerebral palsy is a safe practice and associated with reduced rate of medical and mechanical problems compared to the current literature. This approach should be utilized with optimal pain and tone management.
- Open Access
Vitamin D Deficiency in Orthopedic Patients in Different Latitudes—First Study Comparing German and Greek Populations
Vitamin D plays a pivotal role in calcium metabolism and bone mineralization. Sufficient vitamin D levels are important for the health and functionality of the musculoskeletal system. Hypovitaminosis D is a phenomenon affecting orthopedic patients worldwide. This study researched whether most orthopedic patients in two different cities of different countries had hypovitaminosis D, whether there was a correlation between sunshine hours and vitamin D serum levels, and whether hours of sunshine alone were enough to achieve vitamin D sufficiency among orthopedic patients regardless of their activities. The vitamin D serum levels of 500 orthopedic patients in Regensburg and 500 in Patras were assessed, in addition to their medical histories. The mean sunshine hours throughout the year were also calculated. Both the German and Greek groups showed hypovitaminosis D. Older patients were more affected. Although there were more hours of sunshine in Greece, Greek orthopedic patients also showed hypovitaminosis D. Hypovitaminosis D affects orthopedic patients independent of their latitude. Supplementation of vitamin D may be considered among orthopedic patients to achieve sufficient levels in serum. Sufficient vitamin D levels may be helpful for the treatment of orthopedic patients, reduce the negative effects of operations or postoperational settings.
Open AccessVitamin D Deficiency in Orthopedic Patients in Different Latitudes—First Study Comparing German and Greek Populations
Vitamin D plays a pivotal role in calcium metabolism and bone mineralization. Sufficient vitamin D levels are important for the health and functionality of the musculoskeletal system. Hypovitaminosis D is a phenomenon affecting orthopedic patients worldwide. This study researched whether most orthopedic patients in two different cities of different countries had hypovitaminosis D, whether there was a correlation between sunshine hours and vitamin D serum levels, and whether hours of sunshine alone were enough to achieve vitamin D sufficiency among orthopedic patients regardless of their activities. The vitamin D serum levels of 500 orthopedic patients in Regensburg and 500 in Patras were assessed, in addition to their medical histories. The mean sunshine hours throughout the year were also calculated. Both the German and Greek groups showed hypovitaminosis D. Older patients were more affected. Although there were more hours of sunshine in Greece, Greek orthopedic patients also showed hypovitaminosis D. Hypovitaminosis D affects orthopedic patients independent of their latitude. Supplementation of vitamin D may be considered among orthopedic patients to achieve sufficient levels in serum. Sufficient vitamin D levels may be helpful for the treatment of orthopedic patients, reduce the negative effects of operations or postoperational settings.
- Open Access
- 1 May 2015
- Published by Springer Nature in Scoliosis
- Vol. 10 (1) , 1-7
Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw
The pullout strength of pedicle screws is influenced by many factors, including diameter of the screws, implant design, and augmentation with bone cement such as PMMA. In the present study, the pullout strength of an innovative fenestrated screw augmented with PMMA was investigated and was compared to unaugmented fenestrated, standard and dual outer diameter screw. Twenty four thoracolumbar vertebrae (T10-L5, age 60 to 70 years) from three cadavers were implanted with the four different pedicle screws. Twelve screws of each type were instrumented into either left or right pedicle with standard screw paired with unaugmented and dual outer diameter screw paired with augmented fenestrated screw in any given vertebra. Axial pullout testing was conducted at a rate of 5 mm/min. Force to failure (Newtons) for each pedicle screw was recorded. The augmented fenestrated screws had the highest pullout strength, which represented an average increase of 149%, 141%, and 78% in comparison to unaugmented, standard, and dual outer diameter screws, respectively. Pullout strength of unaugmented screws was comparable to that of standard screws, however it was significantly lower than dual outer diameter screws. Fenestrated screws augmented with PMMA improve the fixation strength and result in significantly higher pullout strength compared to dual outer diameter, standard and unaugmented fenestrated screws. Screws with dual outer diameter provided enhanced bone-screw purchase and may be considered as an alternative technique to increase the bone-screw interface in cases where augmentation using bone cement is not feasible. Unaugmented screws can be left in the pedicle even without cement and provide similar pullout strength to standard screws.
- 1 May 2015
- Published by Springer Nature in Scoliosis
- Vol. 10 (1) , 1-7
Open AccessAxial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw
The pullout strength of pedicle screws is influenced by many factors, including diameter of the screws, implant design, and augmentation with bone cement such as PMMA. In the present study, the pullout strength of an innovative fenestrated screw augmented with PMMA was investigated and was compared to unaugmented fenestrated, standard and dual outer diameter screw. Twenty four thoracolumbar vertebrae (T10-L5, age 60 to 70 years) from three cadavers were implanted with the four different pedicle screws. Twelve screws of each type were instrumented into either left or right pedicle with standard screw paired with unaugmented and dual outer diameter screw paired with augmented fenestrated screw in any given vertebra. Axial pullout testing was conducted at a rate of 5 mm/min. Force to failure (Newtons) for each pedicle screw was recorded. The augmented fenestrated screws had the highest pullout strength, which represented an average increase of 149%, 141%, and 78% in comparison to unaugmented, standard, and dual outer diameter screws, respectively. Pullout strength of unaugmented screws was comparable to that of standard screws, however it was significantly lower than dual outer diameter screws. Fenestrated screws augmented with PMMA improve the fixation strength and result in significantly higher pullout strength compared to dual outer diameter, standard and unaugmented fenestrated screws. Screws with dual outer diameter provided enhanced bone-screw purchase and may be considered as an alternative technique to increase the bone-screw interface in cases where augmentation using bone cement is not feasible. Unaugmented screws can be left in the pedicle even without cement and provide similar pullout strength to standard screws.