Alejandro Rivas-Campo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alejandro Rivas-Campo has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Maroun T. Semaan
University Hospitals Cleveland Medical Center
2 shared publications - Sarah E. Mowry
University Hospitals Cleveland Medical Center
2 shared publications - Alexandra M. Arambula
Department of Otolaryngology–Head and Neck Surgery, University Hospitals Cleveland Medical Center
1 shared publication - Allison Biever
Rocky Mountain Ear Center, Englewood
1 shared publication - Benjamin R. Johnson
Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Case Western Reserve University and University Hospitals Cleveland Medical Center, Cleveland, USA
1 shared publication - Brian J. Kaplan
Greater Baltimore Medical Center, Baltimore, Maryland
1 shared publication
Latest Publications
- Open Access
- 3 April 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (6) , 627-633
Sensitivity and Specificity of Intraoperative TransImpedance Matrix Recordings Compared With X-ray Imaging in Detecting Perimodiolar Cochlear Implant Tip Foldovers: A Multicenter Study
Objective: Characterize the sensitivity and specificity of TransImpedance Matrix (TIM) recordings compared with x-rays in detecting cochlear implant tip foldovers. Study Design: Retrospective. Setting: Multi-institutional, academic and private surgery centers. Patients: Patients 6 months and older undergoing cochlear implantation. Interventions: After cochlear implant array insertion, intraoperative TIM recordings and x-rays were conducted to confirm appropriate placement. If a foldover was identified, repeat insertion, followed by TIM and x-ray, was performed. Main Outcome Measures: Presence of tip foldovers as determined by TIM recordings and x-rays. Results: There were 13 tip foldovers out of 484 insertions, yielding a 2.7% tip foldover rate. Using x-rays as the “gold standard,” TIM recordings showed 100% sensitivity, 99.6% specificity, 84.6% positive predictive value (PPV), and 100% negative predicative value in detecting tip foldovers. The x-ray images for two TIM-identified tip foldovers were interpreted as normal intraoperatively (apparent false positives), but then were interpreted as foldovers when presented to the operating surgeon postoperatively in a blinded fashion. If these false positives had been reclassified as true positives, TIM specificity and PPV would both improve to 100%. Conclusions: These results provide further support regarding the utility of TIM recordings to evaluate appropriate cochlear implant electrode array position. Despite the low tip foldover rate reported across the literature and within this study, this multicenter patient group provided a large sample size to calculate the sensitivity and specificity of TIM recordings in identifying tip foldovers. Compared with the reference-standard, x-ray imaging, TIM recordings show equivalent, and in some cases superior, performance in identification of tip foldovers. Thus, use of TIM can potentially preclude the need for routine intraoperative x-rays without compromising patient care.
- 3 April 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (6) , 627-633
Open AccessSensitivity and Specificity of Intraoperative TransImpedance Matrix Recordings Compared With X-ray Imaging in Detecting Perimodiolar Cochlear Implant Tip Foldovers: A Multicenter Study
Objective: Characterize the sensitivity and specificity of TransImpedance Matrix (TIM) recordings compared with x-rays in detecting cochlear implant tip foldovers. Study Design: Retrospective. Setting: Multi-institutional, academic and private surgery centers. Patients: Patients 6 months and older undergoing cochlear implantation. Interventions: After cochlear implant array insertion, intraoperative TIM recordings and x-rays were conducted to confirm appropriate placement. If a foldover was identified, repeat insertion, followed by TIM and x-ray, was performed. Main Outcome Measures: Presence of tip foldovers as determined by TIM recordings and x-rays. Results: There were 13 tip foldovers out of 484 insertions, yielding a 2.7% tip foldover rate. Using x-rays as the “gold standard,” TIM recordings showed 100% sensitivity, 99.6% specificity, 84.6% positive predictive value (PPV), and 100% negative predicative value in detecting tip foldovers. The x-ray images for two TIM-identified tip foldovers were interpreted as normal intraoperatively (apparent false positives), but then were interpreted as foldovers when presented to the operating surgeon postoperatively in a blinded fashion. If these false positives had been reclassified as true positives, TIM specificity and PPV would both improve to 100%. Conclusions: These results provide further support regarding the utility of TIM recordings to evaluate appropriate cochlear implant electrode array position. Despite the low tip foldover rate reported across the literature and within this study, this multicenter patient group provided a large sample size to calculate the sensitivity and specificity of TIM recordings in identifying tip foldovers. Compared with the reference-standard, x-ray imaging, TIM recordings show equivalent, and in some cases superior, performance in identification of tip foldovers. Thus, use of TIM can potentially preclude the need for routine intraoperative x-rays without compromising patient care.
- 1 January 2022
- Published by Springer Nature
- p. 361-374
Endolymphatic Hydrops