Liuhong Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Liuhong Zhu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Congbo Cai
Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
2 shared publications Funan Wang
Fudan University Zhongshan Hospital Xiamen Branch
2 shared publicationsJianfa Chen
Xiamen University
2 shared publicationsJianjun Zhou
Zhongshan Hospital (Xiamen) Fudan University
2 shared publicationsNuowei Ge
Xiamen University
2 shared publications- Qinqin Yang
Department of Radiological Sciences University of California Irvine Irvine California USA
2 shared publications
Latest Publications
- 3 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (17) , 175021
Rapid whole-brain susceptibility source separation using sub-minute three-dimensional multiple overlapping-echo detachment acquisition
Objective. Magnetic susceptibility source separation provides profound insights into tissue pathophysiology by disentangling the underlying paramagnetic and diamagnetic sources within the human brain. However, the highly time-consuming nature of existing acquisition techniques creates a critical need for rapid and reliable separation methodologies to facilitate routine clinical applications. Approach. A highly accelerated framework for whole-brain magnetic susceptibility source separation was proposed by utilizing the ultra-fast 3D-MOLED sequence. This pipeline integrates the advanced deep learning architecture to accurately map the separated susceptibility components without relying on spin echo data. To ensure quantitative stability and structural fidelity, a robust three-dimensional domain adaptation strategy was incorporated during the simulation phase. The performance of the proposed method was systematically evaluated through phantom experiments, healthy volunteer assessments, and clinical examinations of patients with multiple sclerosis. Main results. The proposed framework achieved whole-brain susceptibility source separation at 1 mm isotropic resolution with only 50 s of data acquisition. In healthy volunteers, the paramagnetic and diamagnetic susceptibility maps were highly comparable to those obtained with the conventional multi-echo gradient-echo sequence, with structural similarity indices of 0.9244 ± 0.0181 and 0.9425 ± 0.0186, peak signal-to-noise ratios of 33.76 ± 2.37 and 37.29 ± 3.51 dB, regional coefficients of determination of 0.973 and 0.934, and Bland–Altman biases of −0.0013 and −0.0010 ppm, respectively. Furthermore, clinical evaluations in patients with multiple sclerosis demonstrated consistent characterization of complex lesion-related susceptibility features. Significance. Achieving whole-brain magnetic susceptibility source separation in less than one minute represents a meaningful technical advance. By substantially reducing the acquisition time required for susceptibility source separation, this accelerated framework may improve the feasibility of future clinical translation in neuroimaging workflows.
- 3 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (17) , 175021
Rapid whole-brain susceptibility source separation using sub-minute three-dimensional multiple overlapping-echo detachment acquisition
Objective. Magnetic susceptibility source separation provides profound insights into tissue pathophysiology by disentangling the underlying paramagnetic and diamagnetic sources within the human brain. However, the highly time-consuming nature of existing acquisition techniques creates a critical need for rapid and reliable separation methodologies to facilitate routine clinical applications. Approach. A highly accelerated framework for whole-brain magnetic susceptibility source separation was proposed by utilizing the ultra-fast 3D-MOLED sequence. This pipeline integrates the advanced deep learning architecture to accurately map the separated susceptibility components without relying on spin echo data. To ensure quantitative stability and structural fidelity, a robust three-dimensional domain adaptation strategy was incorporated during the simulation phase. The performance of the proposed method was systematically evaluated through phantom experiments, healthy volunteer assessments, and clinical examinations of patients with multiple sclerosis. Main results. The proposed framework achieved whole-brain susceptibility source separation at 1 mm isotropic resolution with only 50 s of data acquisition. In healthy volunteers, the paramagnetic and diamagnetic susceptibility maps were highly comparable to those obtained with the conventional multi-echo gradient-echo sequence, with structural similarity indices of 0.9244 ± 0.0181 and 0.9425 ± 0.0186, peak signal-to-noise ratios of 33.76 ± 2.37 and 37.29 ± 3.51 dB, regional coefficients of determination of 0.973 and 0.934, and Bland–Altman biases of −0.0013 and −0.0010 ppm, respectively. Furthermore, clinical evaluations in patients with multiple sclerosis demonstrated consistent characterization of complex lesion-related susceptibility features. Significance. Achieving whole-brain magnetic susceptibility source separation in less than one minute represents a meaningful technical advance. By substantially reducing the acquisition time required for susceptibility source separation, this accelerated framework may improve the feasibility of future clinical translation in neuroimaging workflows.
- Open Access
- 31 March 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Spatially decoupled reliable mutual learning for semi-supervised medical image segmentation
Semi-Supervised Learning reduces the annotation burden for medical image segmentation but currently suffers from spatial context overfitting and confirmati
- 31 March 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessSpatially decoupled reliable mutual learning for semi-supervised medical image segmentation
Semi-Supervised Learning reduces the annotation burden for medical image segmentation but currently suffers from spatial context overfitting and confirmati
- 24 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (24)
Model-based spatiotemporal synthetic data generation framework and deep-learning reconstruction for real-time MRI oxygen extraction fraction mapping
Objective: Synthetic data has emerged as a highly efficient solution to address the scarcity of training data in deep learning-based quantitative magnetic resonance imaging (qMRI) reconstruction. However, current applications of synthetic data predominantly focus on two-dimensional spatial reconstruction, with limited capability to leverage the spatiotemporal correlation inherent in real-time dynamic imaging data to further enhance reconstruction quality. Approach: A model-based spatiotemporal synthetic data generation framework tailored for real-time dynamic scenarios in supervised learning-based reconstruction was proposed. This framework is complemented by an ultra-fast multiple overlapping-echo detachment (MOLED) imaging technique, which enables a three-dimensional spatiotemporal reconstruction method designed to track dynamic changes in the oxygen extraction fraction (OEF). The proposed method imposes constraints that align the predicted parameters with the ground truth while ensuring consistency in their singular-value subspaces. Main results: The accuracy and effectiveness of the proposed method for T2 and T2* mapping were validated through numerical brain, water phantom and human brain experiments, demonstrating superior performance compared to both traditional two-dimensional spatial and three-dimensional spatiotemporal reconstruction methods. This framework reliably enabled dynamic OEF tracking during breath-hold and oxygen inhalation cycles, highlighting its robustness and applicability in real-time scenarios. Significance: The model-based spatiotemporal synthetic data generation framework and the spatiotemporal reconstruction method offer an effective and robust solution for real-time qMRI, with potential applications in other similar real-time dynamic quantitative reconstruction tasks. Moreover, the MOLED sequence underscores the potential for precise and dynamic measurement of brain oxygen metabolism, providing valuable insights into cerebral physiology and metabolic changes.
- 24 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (24)
Model-based spatiotemporal synthetic data generation framework and deep-learning reconstruction for real-time MRI oxygen extraction fraction mapping
Objective: Synthetic data has emerged as a highly efficient solution to address the scarcity of training data in deep learning-based quantitative magnetic resonance imaging (qMRI) reconstruction. However, current applications of synthetic data predominantly focus on two-dimensional spatial reconstruction, with limited capability to leverage the spatiotemporal correlation inherent in real-time dynamic imaging data to further enhance reconstruction quality. Approach: A model-based spatiotemporal synthetic data generation framework tailored for real-time dynamic scenarios in supervised learning-based reconstruction was proposed. This framework is complemented by an ultra-fast multiple overlapping-echo detachment (MOLED) imaging technique, which enables a three-dimensional spatiotemporal reconstruction method designed to track dynamic changes in the oxygen extraction fraction (OEF). The proposed method imposes constraints that align the predicted parameters with the ground truth while ensuring consistency in their singular-value subspaces. Main results: The accuracy and effectiveness of the proposed method for T2 and T2* mapping were validated through numerical brain, water phantom and human brain experiments, demonstrating superior performance compared to both traditional two-dimensional spatial and three-dimensional spatiotemporal reconstruction methods. This framework reliably enabled dynamic OEF tracking during breath-hold and oxygen inhalation cycles, highlighting its robustness and applicability in real-time scenarios. Significance: The model-based spatiotemporal synthetic data generation framework and the spatiotemporal reconstruction method offer an effective and robust solution for real-time qMRI, with potential applications in other similar real-time dynamic quantitative reconstruction tasks. Moreover, the MOLED sequence underscores the potential for precise and dynamic measurement of brain oxygen metabolism, providing valuable insights into cerebral physiology and metabolic changes.
- Open Access
- 8 November 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (45) , e40386
Diagnostic accuracy and image quality evaluation of ultrashort echo time MRI in the lungs
This study evaluates the diagnostic accuracy of ultrashort echo time (UTE)-MRI for detecting pulmonary nodules and image quality. A total of 46 patients at our hospital underwent unenhanced computed tomography (CT) and UTE-MRI. The image quality and number of nodules detected using CT were used as the gold standards. Three diagnostic radiologists independently recorded the image quality (visibility and sharpness of normal anatomical structures) of the CT and UTE images and the number of pulmonary nodules detected. The diagnostic accuracy, subjective image quality, and consistency between observations were statistically analyzed. Among 46 patients, 36 (78.2%) had pulmonary nodules on CT images, whereas 10 patients (21.7%) had no pulmonary nodules. A total of 48 lung nodules were detected, 3 of which were ground-glass opacities. UTE-MRI revealed 46 lung nodules. Compared with CT, the sensitivity of all MRI readers for detecting lung lesions was 95.8%, and the 3-observer agreement was nearly perfect (P < .001, Kendall Wa [Kender Harmonious Coefficient] = 0.913). The overall image quality score of the observers was high, ranging from good to excellent, and the consistency of the subjective UTE-MRI image quality was good (Kendall Wa = 0.877, P < .001). For tracheal display, the subsegment of the bronchus was displayed, and the wall of the tube was clearly displayed. The difference in the Wa values between the observers was 0.804 (P < .001), indicating strong consistency. For blood vessels, subsegment blood vessels could also be displayed with clear walls and uniform signals (Kendal Wa = 0.823, P < .001), indicating strong consistency. Compared to CT, UTE-MRI can detect pulmonary nodules with a high detection rate, relatively good image quality, and strong consistency between observers. The development of UTE-MRI can provide a novel imaging method for the detection and follow-up of pulmonary nodules and diagnosis of pneumonia by reducing ionizing radiation.
- 8 November 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (45) , e40386
Open AccessDiagnostic accuracy and image quality evaluation of ultrashort echo time MRI in the lungs
This study evaluates the diagnostic accuracy of ultrashort echo time (UTE)-MRI for detecting pulmonary nodules and image quality. A total of 46 patients at our hospital underwent unenhanced computed tomography (CT) and UTE-MRI. The image quality and number of nodules detected using CT were used as the gold standards. Three diagnostic radiologists independently recorded the image quality (visibility and sharpness of normal anatomical structures) of the CT and UTE images and the number of pulmonary nodules detected. The diagnostic accuracy, subjective image quality, and consistency between observations were statistically analyzed. Among 46 patients, 36 (78.2%) had pulmonary nodules on CT images, whereas 10 patients (21.7%) had no pulmonary nodules. A total of 48 lung nodules were detected, 3 of which were ground-glass opacities. UTE-MRI revealed 46 lung nodules. Compared with CT, the sensitivity of all MRI readers for detecting lung lesions was 95.8%, and the 3-observer agreement was nearly perfect (P < .001, Kendall Wa [Kender Harmonious Coefficient] = 0.913). The overall image quality score of the observers was high, ranging from good to excellent, and the consistency of the subjective UTE-MRI image quality was good (Kendall Wa = 0.877, P < .001). For tracheal display, the subsegment of the bronchus was displayed, and the wall of the tube was clearly displayed. The difference in the Wa values between the observers was 0.804 (P < .001), indicating strong consistency. For blood vessels, subsegment blood vessels could also be displayed with clear walls and uniform signals (Kendal Wa = 0.823, P < .001), indicating strong consistency. Compared to CT, UTE-MRI can detect pulmonary nodules with a high detection rate, relatively good image quality, and strong consistency between observers. The development of UTE-MRI can provide a novel imaging method for the detection and follow-up of pulmonary nodules and diagnosis of pneumonia by reducing ionizing radiation.
- Open Access
- 5 January 2023
- Published by Springer Nature in Research Square
The potential of ultra short echo time MRI in lung: diagnostic accuracy and image quality evaluation
Objective To evaluate the diagnostic accuracy in the detection of pulmonary nodules and image quality of UTE-MRI imaging using ultra short echo time MRI (UTE-MRI). Methods A total of 48 patients in our hospital were collected and underwent CT unenhance scan and UTE-MRI scan. The image quality and number of nodules detected by CT were taken as the gold standard. Three diagnostic radiologists independently recorded the image quality (such as visibility and sharpness of normal anatomical structures) of CT and UTE and the number of pulmonary nodules detected. The diagnostic accuracy, subjective image quality and consistency between observations were statistically analyzed. Results Among 46 patients, 36 patients (78.2%) had pulmonary nodules on CT image, while 10 patients (21.7%) had no pulmonary nodules. A total of 48 lung nodules were detected, of which 3 were ground glass nodules. On UTE-MRI, a total of 46 lung nodules were detected. Compared with CT, the sensitivity of all MRI readers to detect lung lesions was 95.8%, and the three-observer agreement was nearly perfect (p < 0.001, Kendall Wa (Kender’s Harmonious Coefficientt) = 0.913). The overall image quality score of the observers was high, ranging from good to excellent, and the consistency of UTE-MRI subjective image quality was good: Kendall Wa =0.877, P < 0.001, strong consistency; For tracheal display, the subsegment of bronchus could be displayed, and the wall of the tube was clearly displayed. The Wa value between observers was 0.804,P < 0.001, strong consistency. As for the display of blood vessels, subsegment blood vessels can also be displayed, with clear wall and uniform signal, Kendal Wa =0.823, P < 0.001, strong consistency. Conclusion Compared with CT, UTE-MRI can detect pulmonary nodules with a high detection rate, and the image quality is relatively good, and the consistency between observers is strong. The application of UTE-MRI may provide an alternative imaging method for the detection or follow-up of pulmonary nodules and the diagnosis of pneumonia under the condition of reducing ionizing radiation.
- 5 January 2023
- Published by Springer Nature in Research Square
Open AccessThe potential of ultra short echo time MRI in lung: diagnostic accuracy and image quality evaluation
Objective To evaluate the diagnostic accuracy in the detection of pulmonary nodules and image quality of UTE-MRI imaging using ultra short echo time MRI (UTE-MRI). Methods A total of 48 patients in our hospital were collected and underwent CT unenhance scan and UTE-MRI scan. The image quality and number of nodules detected by CT were taken as the gold standard. Three diagnostic radiologists independently recorded the image quality (such as visibility and sharpness of normal anatomical structures) of CT and UTE and the number of pulmonary nodules detected. The diagnostic accuracy, subjective image quality and consistency between observations were statistically analyzed. Results Among 46 patients, 36 patients (78.2%) had pulmonary nodules on CT image, while 10 patients (21.7%) had no pulmonary nodules. A total of 48 lung nodules were detected, of which 3 were ground glass nodules. On UTE-MRI, a total of 46 lung nodules were detected. Compared with CT, the sensitivity of all MRI readers to detect lung lesions was 95.8%, and the three-observer agreement was nearly perfect (p < 0.001, Kendall Wa (Kender’s Harmonious Coefficientt) = 0.913). The overall image quality score of the observers was high, ranging from good to excellent, and the consistency of UTE-MRI subjective image quality was good: Kendall Wa =0.877, P < 0.001, strong consistency; For tracheal display, the subsegment of bronchus could be displayed, and the wall of the tube was clearly displayed. The Wa value between observers was 0.804,P < 0.001, strong consistency. As for the display of blood vessels, subsegment blood vessels can also be displayed, with clear wall and uniform signal, Kendal Wa =0.823, P < 0.001, strong consistency. Conclusion Compared with CT, UTE-MRI can detect pulmonary nodules with a high detection rate, and the image quality is relatively good, and the consistency between observers is strong. The application of UTE-MRI may provide an alternative imaging method for the detection or follow-up of pulmonary nodules and the diagnosis of pneumonia under the condition of reducing ionizing radiation.
- Open Access
- 25 February 2020
- Published by Springer Nature in Research Square
Evaluation of spectral CT in differentiating metastatic from non-metastatic lymph nodes in non-small cell lung cancer(NSCLC)
Background Lung cancer is the main cause of tumor-correlated deaths, analysis of lymph nodes is crucial to staging of lung cancer. The purpose of the study is to explore the importance of spectral CT imaging in the difference prognostic of metastatic and non-metastatic mediastinal lymph nodes in non-small cell lung cancer. Methods A retrospective examination of 76 patients with non-small cell lung tumor who underwent spectral CT was performed. Quantifiable GSI (Gemstone spectral imaging) parameters (eg, 40 keV, iodine concentration, water concentration) were calculated in non-contrast, arterial and venous phase in 110 mediastinal lymph nodes using AW4.6 (GE HEALTHCARE, USA). Results The CT values of 40 kev, λHU (The slope of Hounsfield unit curve) and IC(values of iodine concentration values), WC(values of water concentration) measured at the arterial or venous phase were not significantly different from those of metastatic growth lymph nodes (P > 0.05). The net value of Arterial phase (nIAP,net value of iodine concentration in Arterial phase) and vein phase (nIVP, net value of iodine concentration in vein phase) were calculated. The value of nIAP was the difference between IAP (iodine concentration of arterial phase) and INCP (iondine concentration of non-contrast phase), while the value of nIVP was the difference between IVP (iodine concentration of venous phase) and INCP. There stood no noteworthy difference in nIAP amid metastatic lymph nodes and non-metastatic lymph nodes (P = 0.110). There was a substantial difference in nIVP amid metastatic lymph nodes and non-metastatic lymph nodes (P = 0.001). Conclusions Compared with qualitative assessment with conventional CT imaging features, quantitative GSI parameters (nIVP) showed higher accuracy for the preoperative diagnosis of mediastal lymph nodal metastases in patients with NSCLC.
- 25 February 2020
- Published by Springer Nature in Research Square
Open AccessEvaluation of spectral CT in differentiating metastatic from non-metastatic lymph nodes in non-small cell lung cancer(NSCLC)
Background Lung cancer is the main cause of tumor-correlated deaths, analysis of lymph nodes is crucial to staging of lung cancer. The purpose of the study is to explore the importance of spectral CT imaging in the difference prognostic of metastatic and non-metastatic mediastinal lymph nodes in non-small cell lung cancer. Methods A retrospective examination of 76 patients with non-small cell lung tumor who underwent spectral CT was performed. Quantifiable GSI (Gemstone spectral imaging) parameters (eg, 40 keV, iodine concentration, water concentration) were calculated in non-contrast, arterial and venous phase in 110 mediastinal lymph nodes using AW4.6 (GE HEALTHCARE, USA). Results The CT values of 40 kev, λHU (The slope of Hounsfield unit curve) and IC(values of iodine concentration values), WC(values of water concentration) measured at the arterial or venous phase were not significantly different from those of metastatic growth lymph nodes (P > 0.05). The net value of Arterial phase (nIAP,net value of iodine concentration in Arterial phase) and vein phase (nIVP, net value of iodine concentration in vein phase) were calculated. The value of nIAP was the difference between IAP (iodine concentration of arterial phase) and INCP (iondine concentration of non-contrast phase), while the value of nIVP was the difference between IVP (iodine concentration of venous phase) and INCP. There stood no noteworthy difference in nIAP amid metastatic lymph nodes and non-metastatic lymph nodes (P = 0.110). There was a substantial difference in nIVP amid metastatic lymph nodes and non-metastatic lymph nodes (P = 0.001). Conclusions Compared with qualitative assessment with conventional CT imaging features, quantitative GSI parameters (nIVP) showed higher accuracy for the preoperative diagnosis of mediastal lymph nodal metastases in patients with NSCLC.