Simon Le Floc’h
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Simon Le Floc’h has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Abderrahmane Kheddar
CNRS-AIST Joint Robotics Laboratory, IRL3218, Tsukuba, Japan
2 shared publications - Franck Jourdan
Laboratoire de Mécanique et Génie Civil
2 shared publications - Léa Boillereaux
LMGC and the LIRMM, CNRS-University of Montpellier, Montpellier, France
2 shared publications - Arnaud Tanguy
LIRMM, CNRS-University of Montpellier, Montpellier, France
1 shared publication C. Cavinato
1 shared publicationDanièle Noël
IRMB University of Montpellier, INSERM Montpellier France
1 shared publication
Latest Publications
- Open Access
- 16 September 2026
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 12
Normal and shear forces measurements at the interface of the skin–knee distraction orthosis during squatting: A feasibility study
- 16 September 2026
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 12
Open AccessNormal and shear forces measurements at the interface of the skin–knee distraction orthosis during squatting: A feasibility study
- Open Access
- 24 October 2025
- Published by Centre pour la Communication Scientifique Directe (CCSD) in Multidisciplinary Biomechanics Journal
- Vol. 50th congr (Cellular a)
A novel compression device to study the deformation of articular cartilage in murine model through dynamic imaging of mechanical loading
- 24 October 2025
- Published by Centre pour la Communication Scientifique Directe (CCSD) in Multidisciplinary Biomechanics Journal
- Vol. 50th congr (Cellular a)
Open AccessA novel compression device to study the deformation of articular cartilage in murine model through dynamic imaging of mechanical loading
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 621-632
A Distraction Knee-Brace and a Robotic Testbed for Tibiofemoral Load Reduction During Squatting
We design and evaluate a new knee distraction unloader brace. The proposed device conforms to the nonlinear behavior of the tibiofemoral contact force during squat motions, by means of patient-custom cams. Using pneumatic cylinders as springs, the unloading assistance provided by the brace is tailored to the patient’s pathology and adjusted during the rehabilitation process. To assess the performance of our orthosis, various tests are conducted to evaluate its efficiency in terms of tibiofemoral contact load reduction. For this purpose, a robotic test-bench, equipped with a robotic arm, emulates upper leg motion under applied forces (hybrid force-motion control). A pseudo-leg is attached to the robot end-effector, and the orthosis is mounted onto it. The test bench is instrumented with two six degrees of freedom force-torque sensors. Using these force sensors as ground truth, tibiofemoral contact force measurements are obtained with and without our orthosis and compared. A pair of cams is fabricated based on data from a patient whose information is retrieved from the Orthoload database. Experimental results demonstrate a contact force reduction of up to 100 force range corresponding to the robot’s maximum capacity.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 621-632
A Distraction Knee-Brace and a Robotic Testbed for Tibiofemoral Load Reduction During Squatting
We design and evaluate a new knee distraction unloader brace. The proposed device conforms to the nonlinear behavior of the tibiofemoral contact force during squat motions, by means of patient-custom cams. Using pneumatic cylinders as springs, the unloading assistance provided by the brace is tailored to the patient’s pathology and adjusted during the rehabilitation process. To assess the performance of our orthosis, various tests are conducted to evaluate its efficiency in terms of tibiofemoral contact load reduction. For this purpose, a robotic test-bench, equipped with a robotic arm, emulates upper leg motion under applied forces (hybrid force-motion control). A pseudo-leg is attached to the robot end-effector, and the orthosis is mounted onto it. The test bench is instrumented with two six degrees of freedom force-torque sensors. Using these force sensors as ground truth, tibiofemoral contact force measurements are obtained with and without our orthosis and compared. A pair of cams is fabricated based on data from a patient whose information is retrieved from the Orthoload database. Experimental results demonstrate a contact force reduction of up to 100 force range corresponding to the robot’s maximum capacity.
- Top Cited PapersOpen Access
- 30 December 2022
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 111 (7) , 1067-1089
Cartilage biomechanics: From the basic facts to the challenges of tissue engineering
Articular cartilage (AC) is the thin tissue that covers the long bone ends in the joints and that ensures the transmission of forces between adjacent bones while allowing nearly frictionless movements between them. AC repair is a technologic and scientific challenge that has been addressed with numerous approaches. A major deadlock is the capacity to take in account its complex mechanical properties in repair strategies. In this review, we first describe the major mechanical behaviors of AC for the non‐specialists. Then, we show how researchers have progressively identified specific mechanical parameters using mathematical models. There are still gaps in our understanding of some of the observations concerning AC biomechanical properties, particularly the differences in extracellular matrix stiffness measured at the microscale and at the millimetric scale. Nevertheless, for bioengineering applications, AC repair strategies must take into account what are commonly considered the main mechanical features of cartilage: its ability to withstand high stresses through three main behaviors (elasticity, poroelasticity and swelling). Finally, we emphasize that future studies need to investigate AC mechanical properties at different scales, particularly the gradient of mechanical properties around cells and across the cartilage depth, and the differences in mechanical properties at different scales. This multi‐scale approach could greatly enhance the success of AC restorative approaches.
- 30 December 2022
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 111 (7) , 1067-1089
Top Cited PapersOpen AccessCartilage biomechanics: From the basic facts to the challenges of tissue engineering
Articular cartilage (AC) is the thin tissue that covers the long bone ends in the joints and that ensures the transmission of forces between adjacent bones while allowing nearly frictionless movements between them. AC repair is a technologic and scientific challenge that has been addressed with numerous approaches. A major deadlock is the capacity to take in account its complex mechanical properties in repair strategies. In this review, we first describe the major mechanical behaviors of AC for the non‐specialists. Then, we show how researchers have progressively identified specific mechanical parameters using mathematical models. There are still gaps in our understanding of some of the observations concerning AC biomechanical properties, particularly the differences in extracellular matrix stiffness measured at the microscale and at the millimetric scale. Nevertheless, for bioengineering applications, AC repair strategies must take into account what are commonly considered the main mechanical features of cartilage: its ability to withstand high stresses through three main behaviors (elasticity, poroelasticity and swelling). Finally, we emphasize that future studies need to investigate AC mechanical properties at different scales, particularly the gradient of mechanical properties around cells and across the cartilage depth, and the differences in mechanical properties at different scales. This multi‐scale approach could greatly enhance the success of AC restorative approaches.
- Open Access
- 18 November 2021
- Published by Centre pour la Communication Scientifique Directe (CCSD) in Journal of Theoretical, Computational and Applied Mechanics
Residual strains estimation in the annulus fibrosus through digital image correlation
Up-to-date, back pain is among the most prevalent health issues and generally takes its origins from lesions of the annulus fibrosus (AF). While the AF ex vivo mechanical properties are increasingly well understood, in vivo data are still missing. In particular, very few studies have precisely measured the residual strains within the AF and thus the in vivo deformation state of the AF is still miss-interpreted and miss-evaluated. In this work, we propose an original and robust method for the AF residual strains quantification via digital image correlation technics. Ten pig annulus fibrosus were extracted from adjacent vertebrae followed by a radial incision to release the residual strains. The operations were filmed and then analyzed by a custom digital image correlation software in order to quantify the circumferential, radial and shear residual deformations. Our results show that residual strains are of the same order of magnitude than the in vivo one. The average circumferential strains are in tension on the outer periphery ([3.32; 5.94]%) and in compression on the inner periphery ([−6.4; −1.69]%). The mean radial residual strains are essentially in compression ([−10.4; 2.29]%). Locally, radial and circumferential residual strains can reach really large values up to 40% of compression. The mean shear strains remain very small (−0.04% ± 2.88%). This study also shows that circumferential and radial residual strains evolve linearly along the radius and non-linearly along the angle. We propose a simple model to predict their spatial variations. Our results and methods will allow the quantification of more realistic in vivo strains and stresses within the human intervertebral disc.
- 18 November 2021
- Published by Centre pour la Communication Scientifique Directe (CCSD) in Journal of Theoretical, Computational and Applied Mechanics
Open AccessResidual strains estimation in the annulus fibrosus through digital image correlation
Up-to-date, back pain is among the most prevalent health issues and generally takes its origins from lesions of the annulus fibrosus (AF). While the AF ex vivo mechanical properties are increasingly well understood, in vivo data are still missing. In particular, very few studies have precisely measured the residual strains within the AF and thus the in vivo deformation state of the AF is still miss-interpreted and miss-evaluated. In this work, we propose an original and robust method for the AF residual strains quantification via digital image correlation technics. Ten pig annulus fibrosus were extracted from adjacent vertebrae followed by a radial incision to release the residual strains. The operations were filmed and then analyzed by a custom digital image correlation software in order to quantify the circumferential, radial and shear residual deformations. Our results show that residual strains are of the same order of magnitude than the in vivo one. The average circumferential strains are in tension on the outer periphery ([3.32; 5.94]%) and in compression on the inner periphery ([−6.4; −1.69]%). The mean radial residual strains are essentially in compression ([−10.4; 2.29]%). Locally, radial and circumferential residual strains can reach really large values up to 40% of compression. The mean shear strains remain very small (−0.04% ± 2.88%). This study also shows that circumferential and radial residual strains evolve linearly along the radius and non-linearly along the angle. We propose a simple model to predict their spatial variations. Our results and methods will allow the quantification of more realistic in vivo strains and stresses within the human intervertebral disc.