Zakaria Habib
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zakaria Habib has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Nathaniel Taylor
Division of Electromagnetic Engineering, School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, Stockholm, Sweden
2 shared publications- Davood Babazadeh
Hamburg University of Technology
1 shared publication - Ebrahim Shayesteh
Department of Electromagnetic Engineering, KTH Royal Institute of Technology, Stockholm, Sweden
1 shared publication - Elin Karlsson
Department of Health, Medicine, and Caring Sciences, Linköping University, Linköping, Sweden
1 shared publication Jianping Wang
ABB Corporate Research Center Sweden
1 shared publication- Lars Nordstrom
Department of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden
1 shared publication
Latest Publications
- Open Access
- 24 March 2023
- Published by MDPI AG in Electricity
- Vol. 4 (2) , 96-113
Incremental Phase-Current Based Fault Passage Indication for Earth Faults in Resonant Earthed Networks
We propose a method for the fault passage indication of earth faults in resonant-earthed networks, based on phase current measurements alone. This is particularly relevant for electricity distribution systems at medium-voltage levels. The method is based on the relative magnitudes of the phasor changes in the phase currents due to the fault. It is tested for various network types and operation configurations by simulating the network in pscad and using the simulated currents as the input for an implementation of the method in matlab. In over-compensated networks, the method shows reliable detection of the fault passage, with good selectivity and sensitivity for both homogeneous and mixed (cable and overhead line) feeders. However, for the less common under-compensated systems, it has limitations that are described further in this study. The method has good potential for being cost effective since it requires only current measurements, from a single location, at a moderate sampling rate.
- 24 March 2023
- Published by MDPI AG in Electricity
- Vol. 4 (2) , 96-113
Open AccessIncremental Phase-Current Based Fault Passage Indication for Earth Faults in Resonant Earthed Networks
We propose a method for the fault passage indication of earth faults in resonant-earthed networks, based on phase current measurements alone. This is particularly relevant for electricity distribution systems at medium-voltage levels. The method is based on the relative magnitudes of the phasor changes in the phase currents due to the fault. It is tested for various network types and operation configurations by simulating the network in pscad and using the simulated currents as the input for an implementation of the method in matlab. In over-compensated networks, the method shows reliable detection of the fault passage, with good selectivity and sensitivity for both homogeneous and mixed (cable and overhead line) feeders. However, for the less common under-compensated systems, it has limitations that are described further in this study. The method has good potential for being cost effective since it requires only current measurements, from a single location, at a moderate sampling rate.
- Open Access
- 5 January 2023
- Published by Elsevier in Energy Reports
- Vol. 9, 1731-1742
Distributed fault-passage indicators versus central fault location: Comparison for reliability centred planning of resonant-earthed distribution systems
- 5 January 2023
- Published by Elsevier in Energy Reports
- Vol. 9, 1731-1742
Open AccessDistributed fault-passage indicators versus central fault location: Comparison for reliability centred planning of resonant-earthed distribution systems
- Open Access
- 20 August 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2018 (15) , 876-880
Phase shift compensation method for the line differential protection on UHV‐AC transmission lines
Line differential protection is popular for its good selectivity and simplicity as long as there is a dependable communication system between the two ends of the line. However, the sensitivity needs to be compromised when the traditional line differential scheme is applied for ultra‐high voltage (UHV)‐alternating current lines because of the large charging current. A study of the impact of the UHV transmission line characteristics on line differential protection and a proposed solution based on the compensation of the phase shift that exists between the sending and receiving end currents are presented.
- 20 August 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2018 (15) , 876-880
Open AccessPhase shift compensation method for the line differential protection on UHV‐AC transmission lines
Line differential protection is popular for its good selectivity and simplicity as long as there is a dependable communication system between the two ends of the line. However, the sensitivity needs to be compromised when the traditional line differential scheme is applied for ultra‐high voltage (UHV)‐alternating current lines because of the large charging current. A study of the impact of the UHV transmission line characteristics on line differential protection and a proposed solution based on the compensation of the phase shift that exists between the sending and receiving end currents are presented.
- 11 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Distributed secondary frequency control considering rapid start units using alternating direction method of multipliers
Secondary frequency control plays a vital role in power systems and has therefore been the focus of much research. Recent focus is being targeted towards developing distributed solutions. This paper proposes a fast converging, distributed solution for secondary frequency control on the basis of the Alternating Direction Method of Multipliers (ADMM). For economic benefits the proposed solution integrates the use of rapid start (RS) units. Rapid start units are fast response and high ramp offiine units, which can provide the reserve power in case of need. The proposed control scheme is a distributed solution to combine secondary frequency control, economic dispatch and the RS start up process. Finally, the developed algorithm is tested for a power system model on a real-time co-simulation platform. The results show a fast converging algorithm that provides secondary frequency control compliant with ENTSO-E requirements, and the economical benefits of the inclusion of a rapid start unit.
- 11 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Distributed secondary frequency control considering rapid start units using alternating direction method of multipliers
Secondary frequency control plays a vital role in power systems and has therefore been the focus of much research. Recent focus is being targeted towards developing distributed solutions. This paper proposes a fast converging, distributed solution for secondary frequency control on the basis of the Alternating Direction Method of Multipliers (ADMM). For economic benefits the proposed solution integrates the use of rapid start (RS) units. Rapid start units are fast response and high ramp offiine units, which can provide the reserve power in case of need. The proposed control scheme is a distributed solution to combine secondary frequency control, economic dispatch and the RS start up process. Finally, the developed algorithm is tested for a power system model on a real-time co-simulation platform. The results show a fast converging algorithm that provides secondary frequency control compliant with ENTSO-E requirements, and the economical benefits of the inclusion of a rapid start unit.