Rajveer Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rajveer Singh has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Md Rasheduzzaman
Department of Environmental and Occupational Health and Safety Sciences, East Tennessee State University, Johnson City, TN 37614, USA
6 shared publications - Patrick L. Gurian
Department of Civil Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Str. Curtis 251, Philadelphia, PA 19104, USA
5 shared publications - Kerry Ann Hamilton
The Biodesign Institute Center for Environmental Health Engineering Arizona State University Tempe Arizona USA
4 shared publications - Charles J. Werth
Maseeh Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, 301 East Dean Keeton Street, Austin 78712, Texas, United States
3 shared publications - Dienye Lydia Tolofari
Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
3 shared publications Bruce W. Fouke
Carl R. Woese Institute for Genomic Biology, University of Illinois, Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801, USA; Energy Bioscience Institute, University of Illinois Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801, USA; Department of Geology, University of Illinois Urbana-Champaign, 1301 W. Green Street, Urbana, IL 61801, USA; Department of Microbiology, University of Illinois, Urbana-Champaign, 601 S. Goodwin Avenue, Urbana, IL 61801, USA
2 shared publications
Latest Publications
- Open Access
Practitioners’ Perspective on the Prevalent Water Quality Management Practices for Legionella Control in Large Buildings in the United States
Managing building water systems is complicated by the need to maintain hot water temperatures high enough to control the growth of Legionella spp. while minimizing the risk of scalding. This study assessed water quality management practices in large buildings in the United States. Surveys conducted with building water quality managers found that more than 85% of buildings have hot water temperatures that are consistent with scald risk mitigation guidelines (i.e., 140 °F (60 °C) and recirculation loop > 122 °F (50 °C), respectively; median values for both setpoint and recirculation loop temperatures are 10 °F (6 °C) or more below temperatures recommended for opportunistic pathogen control. These observations suggest that many buildings are prone to Legionella spp. risk. The study also found that 27% of buildings do not comply with guidelines for time to equilibrium hot water temperature, over 33% fail to monitor temperature in the recirculation loop, more than 70% fail to replace or disinfect showerheads, more than 40% lack a written management plan, and only a minority conduct any monitoring of residual disinfectant levels or microbiological quality. Given the rise in Legionellosis infections in recent years, coupled with highlighted water quality concerns because of prolonged water stagnation in plumbing, such as in buildings closed due to COVID-19, current management practices, which appear to be focused on scald risk, may need to be broadened to include greater attention to control of opportunistic pathogens. To accomplish this, there is a need for formal training and resources for facility managers.
Open AccessPractitioners’ Perspective on the Prevalent Water Quality Management Practices for Legionella Control in Large Buildings in the United States
Managing building water systems is complicated by the need to maintain hot water temperatures high enough to control the growth of Legionella spp. while minimizing the risk of scalding. This study assessed water quality management practices in large buildings in the United States. Surveys conducted with building water quality managers found that more than 85% of buildings have hot water temperatures that are consistent with scald risk mitigation guidelines (i.e., 140 °F (60 °C) and recirculation loop > 122 °F (50 °C), respectively; median values for both setpoint and recirculation loop temperatures are 10 °F (6 °C) or more below temperatures recommended for opportunistic pathogen control. These observations suggest that many buildings are prone to Legionella spp. risk. The study also found that 27% of buildings do not comply with guidelines for time to equilibrium hot water temperature, over 33% fail to monitor temperature in the recirculation loop, more than 70% fail to replace or disinfect showerheads, more than 40% lack a written management plan, and only a minority conduct any monitoring of residual disinfectant levels or microbiological quality. Given the rise in Legionellosis infections in recent years, coupled with highlighted water quality concerns because of prolonged water stagnation in plumbing, such as in buildings closed due to COVID-19, current management practices, which appear to be focused on scald risk, may need to be broadened to include greater attention to control of opportunistic pathogens. To accomplish this, there is a need for formal training and resources for facility managers.
- 1 September 2020
- Published by Wiley in AWWA Water Science
- Vol. 2 (5)
Full factorial study of pipe characteristics, stagnation times, and water quality
This study examines the effect of pipe characteristics and stagnation time on nitrification, disinfectant loss, and organic carbon concentrations. Pipe racks consisting of different pipe materials (chlorinated polyvinyl chloride [CPVC], cross‐linked polyethylene [PEX‐B], and copper), diameters (0.75 and 0.5 in.), and water stagnation times (1 week and 12 hr) were set up in two cities with different disinfectants (chloramine and free chlorine) and different corrosion control (orthophosphate vs. pH/alkalinity adjustment). Copper pipe material had lower residual concentrations relative to plastic pipe in both water systems. In the chloramine system, residual concentrations were lower for smaller‐diameter pipes, whereas diameter did not strongly influence residual concentration in the chlorine system. Total organic carbon (TOC) increased during stagnation in the chloramine system. Nitrification was observed in the chloramine system for stagnation times of 1 week and 12 hr, indicating that flushing as frequently as every 12 hr may not be an effective mechanism for nitrification control in building plumbing.
- 1 September 2020
- Published by Wiley in AWWA Water Science
- Vol. 2 (5)
Full factorial study of pipe characteristics, stagnation times, and water quality
This study examines the effect of pipe characteristics and stagnation time on nitrification, disinfectant loss, and organic carbon concentrations. Pipe racks consisting of different pipe materials (chlorinated polyvinyl chloride [CPVC], cross‐linked polyethylene [PEX‐B], and copper), diameters (0.75 and 0.5 in.), and water stagnation times (1 week and 12 hr) were set up in two cities with different disinfectants (chloramine and free chlorine) and different corrosion control (orthophosphate vs. pH/alkalinity adjustment). Copper pipe material had lower residual concentrations relative to plastic pipe in both water systems. In the chloramine system, residual concentrations were lower for smaller‐diameter pipes, whereas diameter did not strongly influence residual concentration in the chlorine system. Total organic carbon (TOC) increased during stagnation in the chloramine system. Nitrification was observed in the chloramine system for stagnation times of 1 week and 12 hr, indicating that flushing as frequently as every 12 hr may not be an effective mechanism for nitrification control in building plumbing.
- 1 September 2020
- Published by Elsevier in Water Research
- Vol. 182, 115943
Required water temperature in hotel plumbing to control Legionella growth
- 1 September 2020
- Published by Elsevier in Water Research
- Vol. 182, 115943
Required water temperature in hotel plumbing to control Legionella growth
- Open Access
Managing Water Quality in Premise Plumbing: Subject Matter Experts’ Perspectives and a Systematic Review of Guidance Documents
Although many guidance documents have been developed to inform the design and operation of building water systems to ensure safe water quality, there is a lack of consensus on some topics. This study interviewed 22 subject matter experts (SMEs) to identify topics of concern for managing water quality in buildings and compared SME views with information available on these topics in 15 systematically screened important guidance documents. The study found 18 design and 11 operational topics as critical for managing water quality in buildings. No one guidance document addressed all these topics, suggesting that a compendium of available guidance is needed. SMEs most frequently recommended temperature and residual disinfectant measurements as good parameters for monitoring overall building water quality. Both SME and guidance document recommendations for temperature for controlling opportunistic pathogen growth were reasonably consistent with water heater setpoint >60 °C. However, hot water temperature recommendations varied between 50 and 55 °C for other locations (i.e., the water temperature at the tap or end of the return loop). On the contrary, recommendations for disinfectant residual levels (0.2–2.0 mg/L), flushing frequency (1–14 days), and allowable time for hot water to reach the tap (10–60 s) were not consistent. While this study was able to reconcile diverging views on some of the water quality topics, such as identifying common guidance for water heater set point to at least 60 °C, it also highlights lack of definitive guidance on other critical topics, such as residual level, flushing frequency, hot water time to tap, and the use of thermostatic mixing valves, indicating that these are significant knowledge gaps that need further investigation. The study concludes that there is a need for developing evidence-based guidance, particularly on the topics where expert opinions diverged.
Open AccessManaging Water Quality in Premise Plumbing: Subject Matter Experts’ Perspectives and a Systematic Review of Guidance Documents
Although many guidance documents have been developed to inform the design and operation of building water systems to ensure safe water quality, there is a lack of consensus on some topics. This study interviewed 22 subject matter experts (SMEs) to identify topics of concern for managing water quality in buildings and compared SME views with information available on these topics in 15 systematically screened important guidance documents. The study found 18 design and 11 operational topics as critical for managing water quality in buildings. No one guidance document addressed all these topics, suggesting that a compendium of available guidance is needed. SMEs most frequently recommended temperature and residual disinfectant measurements as good parameters for monitoring overall building water quality. Both SME and guidance document recommendations for temperature for controlling opportunistic pathogen growth were reasonably consistent with water heater setpoint >60 °C. However, hot water temperature recommendations varied between 50 and 55 °C for other locations (i.e., the water temperature at the tap or end of the return loop). On the contrary, recommendations for disinfectant residual levels (0.2–2.0 mg/L), flushing frequency (1–14 days), and allowable time for hot water to reach the tap (10–60 s) were not consistent. While this study was able to reconcile diverging views on some of the water quality topics, such as identifying common guidance for water heater set point to at least 60 °C, it also highlights lack of definitive guidance on other critical topics, such as residual level, flushing frequency, hot water time to tap, and the use of thermostatic mixing valves, indicating that these are significant knowledge gaps that need further investigation. The study concludes that there is a need for developing evidence-based guidance, particularly on the topics where expert opinions diverged.
- Open Access
Correction: Rasheduzzaman, M., et al. Reverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri. Water 2019, 11, 1850
The authors regret to report that the paper “Reverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri” contains some erroneous computations
Open AccessCorrection: Rasheduzzaman, M., et al. Reverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri. Water 2019, 11, 1850
The authors regret to report that the paper “Reverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri” contains some erroneous computations
- Open Access
Reverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri
Opportunistic premise plumbing pathogens such as Pseudomonas aeruginosa and Naegleria fowleri are a growing concern in building water systems because of their potential risks to human health. The aim of this study was to determine the critical concentrations of P. aeruginosa and N. fowleri in water that are associated with meaningful public health risks. To determine these concentrations, a reverse quantitative microbial risk assessment (QMRA) was conducted. Environmental concentrations of P. aeruginosa and N. fowleri corresponding to the risk target of one micro-disability-adjusted life year (DALY) per person per year and 10−4 annual risks of illness were calculated for several applicable exposure scenarios. To calculate the concentration of P. aeruginosa, cleaning contact lenses with potentially contaminated tap water in the absence of an appropriate cleaning solution was considered. For N. fowleri, two exposure scenarios, recreational exposure (swimming) and nasal cleansing (via the use of a neti pot™ or similar device) were considered. The highest critical concentration for P. aeruginosa was found to be 33 CFU/L with a 95% confidence interval of (2.0, 118) for the drop exposure scenario using the 10−4 annual risk target. For N. fowleri, based on the DALY approach, critical concentrations were 0.000030 N. fowleri/L for swimming and 0.00000060 N. fowleri/L for neti pot™ use scenario. Considering heat inactivation, the critical concentration limits for P. aeruginosa using the DALY approach and the 10−4 annual risk target approach were found to be 0.55 CFU/L and 55 CFU/L, respectively. For N. fowleri, the 10−4 annual risk target approach resulted in 0.022 N. fowleri/L and the DALY approach resulted in 0.00000064 N. fowleri/L for the neti pot™ scenario. For P. aeruginosa, N50 (the median infective dose) and alpha (α) contributed the most and contact rates the least to the variability and uncertainty of the estimates for all the scenarios. For N. fowleri, N50 and contact rates contributed the most and α the least to the variability and uncertainty to calculate the concentrations for all the scenarios. The QMRA framework implemented in this research can be used to incorporate more information regarding opportunistic pathogens to inform management decisions, and to prioritize the best interventions regarding estimated reduction in infections caused by opportunistic pathogens.
Open AccessReverse QMRA as a Decision Support Tool: Setting Acceptable Concentration Limits for Pseudomonas aeruginosa and Naegleria fowleri
Opportunistic premise plumbing pathogens such as Pseudomonas aeruginosa and Naegleria fowleri are a growing concern in building water systems because of their potential risks to human health. The aim of this study was to determine the critical concentrations of P. aeruginosa and N. fowleri in water that are associated with meaningful public health risks. To determine these concentrations, a reverse quantitative microbial risk assessment (QMRA) was conducted. Environmental concentrations of P. aeruginosa and N. fowleri corresponding to the risk target of one micro-disability-adjusted life year (DALY) per person per year and 10−4 annual risks of illness were calculated for several applicable exposure scenarios. To calculate the concentration of P. aeruginosa, cleaning contact lenses with potentially contaminated tap water in the absence of an appropriate cleaning solution was considered. For N. fowleri, two exposure scenarios, recreational exposure (swimming) and nasal cleansing (via the use of a neti pot™ or similar device) were considered. The highest critical concentration for P. aeruginosa was found to be 33 CFU/L with a 95% confidence interval of (2.0, 118) for the drop exposure scenario using the 10−4 annual risk target. For N. fowleri, based on the DALY approach, critical concentrations were 0.000030 N. fowleri/L for swimming and 0.00000060 N. fowleri/L for neti pot™ use scenario. Considering heat inactivation, the critical concentration limits for P. aeruginosa using the DALY approach and the 10−4 annual risk target approach were found to be 0.55 CFU/L and 55 CFU/L, respectively. For N. fowleri, the 10−4 annual risk target approach resulted in 0.022 N. fowleri/L and the DALY approach resulted in 0.00000064 N. fowleri/L for the neti pot™ scenario. For P. aeruginosa, N50 (the median infective dose) and alpha (α) contributed the most and contact rates the least to the variability and uncertainty of the estimates for all the scenarios. For N. fowleri, N50 and contact rates contributed the most and α the least to the variability and uncertainty to calculate the concentrations for all the scenarios. The QMRA framework implemented in this research can be used to incorporate more information regarding opportunistic pathogens to inform management decisions, and to prioritize the best interventions regarding estimated reduction in infections caused by opportunistic pathogens.
- 31 May 2019
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 73 (8) , 859-869
Extended Multiplicative Signal Correction for Infrared Microspectroscopy of Heterogeneous Samples with Cylindrical Domains
Optical scattering corrections are invoked to computationally distinguish between scattering and absorption contributions to recorded data in infrared (IR) microscopy, with a goal to obtain an absorption spectrum that is relatively free of the effects of sample morphology. Here, we present a modification of the extended multiplicative signal correction (EMSC) approach that allows for spectral recovery from fibers and cylindrical domains in heterogeneous samples. The developed theoretical approach is based on exact Mie theory for infinite cylinders. Although rigorous Mie theory implies utilization of comprehensive and time-consuming calculations, we propose to change the workflow of the original EMSC algorithm to minimize extensive calculations for each recorded spectrum at each iteration step. This makes the modified EMSC approach practical for routine use. First, we tested our approach using synthetic data derived from a rigorous model of scattering from cylinders in an IR microscope. Second, we applied the approach to Fourier transform IR (FT-IR) microspectroscopy data recorded from filamentous fungal and cellulose samples with pronounced fiber-like shapes. While the corrected spectra show greatly reduced baseline offsets and consistency, strongly absorbing regions of the spectrum require further refinement. The modified EMSC algorithm broadly mitigates the effects of scattering, offering a practical approach to more consistent and accurate spectra from cylindrical objects or heterogeneous samples with cylindrical domains.
- 31 May 2019
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 73 (8) , 859-869
Extended Multiplicative Signal Correction for Infrared Microspectroscopy of Heterogeneous Samples with Cylindrical Domains
Optical scattering corrections are invoked to computationally distinguish between scattering and absorption contributions to recorded data in infrared (IR) microscopy, with a goal to obtain an absorption spectrum that is relatively free of the effects of sample morphology. Here, we present a modification of the extended multiplicative signal correction (EMSC) approach that allows for spectral recovery from fibers and cylindrical domains in heterogeneous samples. The developed theoretical approach is based on exact Mie theory for infinite cylinders. Although rigorous Mie theory implies utilization of comprehensive and time-consuming calculations, we propose to change the workflow of the original EMSC algorithm to minimize extensive calculations for each recorded spectrum at each iteration step. This makes the modified EMSC approach practical for routine use. First, we tested our approach using synthetic data derived from a rigorous model of scattering from cylinders in an IR microscope. Second, we applied the approach to Fourier transform IR (FT-IR) microspectroscopy data recorded from filamentous fungal and cellulose samples with pronounced fiber-like shapes. While the corrected spectra show greatly reduced baseline offsets and consistency, strongly absorbing regions of the spectrum require further refinement. The modified EMSC algorithm broadly mitigates the effects of scattering, offering a practical approach to more consistent and accurate spectra from cylindrical objects or heterogeneous samples with cylindrical domains.
- 11 January 2019
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 73 (6) , 687-697
Bulk Protein and Oil Prediction in Soybeans Using Transmission Raman Spectroscopy: A Comparison of Approaches to Optimize Accuracy
Rapid measurements of protein and oil content are important for a variety of uses, from sorting of soybeans at the point of harvest to feedback during soybean meal production. In this study, our goal is to develop a simple protocol to permit rapid and robust quantitative prediction of soybean constituents using transmission Raman spectroscopy (TRS). To develop this approach, we systematically varied the various elements of the measurement process to provide a diverse test bed. First, we utilized an in-house-built benchtop TRS instrument such that suitable optical configurations could be rapidly deployed and analyzed for experimental data collection for individual soybean grains. Second, we also utilized three different soybean varieties with relatively low (33.97%), medium (36.98%), and high protein (41.23%) contents to test the development process. Third, samples from each variety were prepared using whole bean and three different sample treatments (i.e., ground bean, whole meal, and ground meal). In each case, we modeled the data obtained using partial least squares (PLS) regression and assessed spectral metric-based multiple linear regression (metric-MLR) approaches to build robust prediction models. The metric-MLR models showed lower root mean square errors (RMSEPs), and hence better prediction, compared to corresponding classical PLS regression models for both bulk protein and oil for all treatment types. Comparing different sample preparation approaches, a lower RMSEPs was observed for whole meal treatment and thus the metric-MLR modeling with ground meal treatment was considered to be optimal protocol for bulk protein and oil prediction in soybean, with RMSEP values of 1.15 ± 0.04 (R 2 = 0.87) and 0.80 ± 0.02 (R 2 = 0.87) for bulk protein and oil, respectively. These predictions were nearly two- to threefold better (i.e., lower RMSEPs) than the corresponding NIR spectroscopy measurements (i.e., secondary gold standards in grain industry). For content prediction in whole soybean, incorporating physical attributes of individual grains in metric-MLR approach show up to 22% improvement in bulk protein and a relatively mild (up to ∼5%) improvement in bulk oil prediction. The unique combination of metric-MLR modeling approach (which is rare in the field of grain analysis) and sample treatments resulted in improved prediction models; using the physical attributes of individual grains is suggested as a novel measure for improving accuracy in prediction.
- 11 January 2019
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 73 (6) , 687-697
Bulk Protein and Oil Prediction in Soybeans Using Transmission Raman Spectroscopy: A Comparison of Approaches to Optimize Accuracy
Rapid measurements of protein and oil content are important for a variety of uses, from sorting of soybeans at the point of harvest to feedback during soybean meal production. In this study, our goal is to develop a simple protocol to permit rapid and robust quantitative prediction of soybean constituents using transmission Raman spectroscopy (TRS). To develop this approach, we systematically varied the various elements of the measurement process to provide a diverse test bed. First, we utilized an in-house-built benchtop TRS instrument such that suitable optical configurations could be rapidly deployed and analyzed for experimental data collection for individual soybean grains. Second, we also utilized three different soybean varieties with relatively low (33.97%), medium (36.98%), and high protein (41.23%) contents to test the development process. Third, samples from each variety were prepared using whole bean and three different sample treatments (i.e., ground bean, whole meal, and ground meal). In each case, we modeled the data obtained using partial least squares (PLS) regression and assessed spectral metric-based multiple linear regression (metric-MLR) approaches to build robust prediction models. The metric-MLR models showed lower root mean square errors (RMSEPs), and hence better prediction, compared to corresponding classical PLS regression models for both bulk protein and oil for all treatment types. Comparing different sample preparation approaches, a lower RMSEPs was observed for whole meal treatment and thus the metric-MLR modeling with ground meal treatment was considered to be optimal protocol for bulk protein and oil prediction in soybean, with RMSEP values of 1.15 ± 0.04 (R 2 = 0.87) and 0.80 ± 0.02 (R 2 = 0.87) for bulk protein and oil, respectively. These predictions were nearly two- to threefold better (i.e., lower RMSEPs) than the corresponding NIR spectroscopy measurements (i.e., secondary gold standards in grain industry). For content prediction in whole soybean, incorporating physical attributes of individual grains in metric-MLR approach show up to 22% improvement in bulk protein and a relatively mild (up to ∼5%) improvement in bulk oil prediction. The unique combination of metric-MLR modeling approach (which is rare in the field of grain analysis) and sample treatments resulted in improved prediction models; using the physical attributes of individual grains is suggested as a novel measure for improving accuracy in prediction.
- 1 September 2017
- Published by Elsevier in Journal of Contaminant Hydrology
- Vol. 204, 28-39
Real rock-microfluidic flow cell: A test bed for real-time in situ analysis of flow, transport, and reaction in a subsurface reactive transport environment
- 1 September 2017
- Published by Elsevier in Journal of Contaminant Hydrology
- Vol. 204, 28-39
Real rock-microfluidic flow cell: A test bed for real-time in situ analysis of flow, transport, and reaction in a subsurface reactive transport environment
- 8 September 2015
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 49 (20) , 12094-12104
Metabolism-Induced CaCO3 Biomineralization During Reactive Transport in a Micromodel: Implications for Porosity Alteration
The ability of Pseudomonas stutzeri strain DCP-Ps1 to drive CaCO3 biomineralization has been investigated in a microfluidic flowcell (i.e., micromodel) that simulates subsurface porous media. Results indicate that CaCO3 precipitation occurs during NO3– reduction with a maximum saturation index (SIcalcite) of ∼1.56, but not when NO3– was removed, inactive biomass remained, and pH and alkalinity were adjusted to SIcalcite ∼ 1.56. CaCO3 precipitation was promoted by metabolically active cultures of strain DCP-Ps1, which at similar values of SIcalcite, have a more negative surface charge than inactive strain DCP-Ps1. A two-stage NO3– reduction (NO3– → NO2– → N2) pore-scale reactive transport model was used to evaluate denitrification kinetics, which was observed in the micromodel as upper (NO3– reduction) and lower (NO2– reduction) horizontal zones of biomass growth with CaCO3 precipitation exclusively in the lower zone. Model results are consistent with two biomass growth regions and indicate that precipitation occurred in the lower zone because the largest increase in pH and alkalinity is associated with NO2– reduction. CaCO3 precipitates typically occupied the entire vertical depth of pores and impacted porosity, permeability, and flow. This study provides a framework for incorporating microbial activity in biogeochemistry models, which often base biomineralization only on SI (caused by biotic or abiotic reactions) and, thereby, underpredict the extent of this complex process. These results have wide-ranging implications for understanding reactive transport in relevance to groundwater remediation, CO2 sequestration, and enhanced oil recovery.
- 8 September 2015
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 49 (20) , 12094-12104
Metabolism-Induced CaCO3 Biomineralization During Reactive Transport in a Micromodel: Implications for Porosity Alteration
The ability of Pseudomonas stutzeri strain DCP-Ps1 to drive CaCO3 biomineralization has been investigated in a microfluidic flowcell (i.e., micromodel) that simulates subsurface porous media. Results indicate that CaCO3 precipitation occurs during NO3– reduction with a maximum saturation index (SIcalcite) of ∼1.56, but not when NO3– was removed, inactive biomass remained, and pH and alkalinity were adjusted to SIcalcite ∼ 1.56. CaCO3 precipitation was promoted by metabolically active cultures of strain DCP-Ps1, which at similar values of SIcalcite, have a more negative surface charge than inactive strain DCP-Ps1. A two-stage NO3– reduction (NO3– → NO2– → N2) pore-scale reactive transport model was used to evaluate denitrification kinetics, which was observed in the micromodel as upper (NO3– reduction) and lower (NO2– reduction) horizontal zones of biomass growth with CaCO3 precipitation exclusively in the lower zone. Model results are consistent with two biomass growth regions and indicate that precipitation occurred in the lower zone because the largest increase in pH and alkalinity is associated with NO2– reduction. CaCO3 precipitates typically occupied the entire vertical depth of pores and impacted porosity, permeability, and flow. This study provides a framework for incorporating microbial activity in biogeochemistry models, which often base biomineralization only on SI (caused by biotic or abiotic reactions) and, thereby, underpredict the extent of this complex process. These results have wide-ranging implications for understanding reactive transport in relevance to groundwater remediation, CO2 sequestration, and enhanced oil recovery.